• 제목/요약/키워드: Gas scrubber

검색결과 136건 처리시간 0.03초

폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산 (Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production)

  • 선도원;배달희;조성호;이승용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

DASAN C & I

  • 윤승영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.49-49
    • /
    • 2000
  • 당사는 1991년 6월에 설립된 후 반도체 장비의 국산화 개발에 주력하고 있다. Thermoelectric module typer Chiller 및 Dry gas scrubber를 국산화 하였으며 THC(Temperature & Humidity Controller)를 개발하여 국내 및 미국에 특허를 출원중에 있으며 기업 부설연구소를 통해 계속하여 각종 제품을 연구 개발하고 있다. 이외 다수의 제품을 보유하고 있으며 기업 부설연구소를 통해 계속하여 각종 제품을 연구 개발하고 있다. 이외 다수의 제품을 보유하고 있으며 진공관련 제품으로는 미국 MDC사 Vacuum components, e-beam vaporation system. ISI사 electrical and optical components, US Inc. 사 Sputter system, SBC사 Bellows. 일본 IKC사 Bellows, Vacuum components, Vacuum system을 취급하고 있다. 1998년에 경기도 및 중소기업청으로부터 유망중소기업 및 벤처기업 인증을 획득하였으며 1999년 12월에 경기도 및 중소기업청으로부터 유망중소기업 및 벤쳐기업 인증을 획득하였으며 1999년 12월 KOSDAQ에 등록하였다. 중소기업 수출기업화 사업 대상기업으로 선정되었으며 1999년 12월 KOSDAQ에 등록하였다.

  • PDF

EGR시스템 디젤기관의 실린더 및 피스톤 마모에 미치는 재순환 배기의 영향에 관한 연구 (A Study on the Influences of Recirculated Exhaust Gas upon Wear of Cylinder and Piston in Diesel Engines with EGR System)

  • 하정호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.827-835
    • /
    • 1998
  • The effects of recirculated exhaust gas on the wear of cylinder liner piston and piston rings have been investigated by the experiment with a two-cylinder four cycle indirect injection diesel engine operating at 75% load and 1600 rpm speed For the purpose of comparison between the rates of two cylinders with and without EGR the recirculated exhaust gas is sucked into one of two cylinders after the soot among exhaust emissions is removed by an intntionally designed cylinder-type scrubber equipped with 6 water injectors(A water injector has 144 nozzles of 1.0 mm diame-ter) while only the fresh air into another cylinder. These experiments are carried out on the fuel injection at a fixed $15.3^{\circ}$ BTDC timing. It is found that firstly the mean wear amount of cylinder liner with EGR is more increased in the measurement positions of the second half than of the first half and the mean wear amount without EGR is almost uniform regardless of measurement posi-tions secondly the wear rates of the first and second piston ring(compression ring)thickness with EGR are more than twice but the wear rate of oil ring thickness without EGR is more increased than that with EGR and finally the wear rate of piston skirt with EGR is a little bit increased but the piston hed diameter is rather increased owing to soot adhesion and corrosion wear and espe-cially larger with EGR.

  • PDF

가스센서를 활용한 암모니아 가스의 실시간 흡수 효율 평가에 관한 연구 (The Study on the Realtime Evaluation of NH3 Absorption Efficiency Using Chemical Gas Sensor)

  • 임정진;김한수;김선태
    • 대한환경공학회지
    • /
    • 제35권4호
    • /
    • pp.233-239
    • /
    • 2013
  • 본 연구에서는 실험실 규모의 스크러버 전단과 후단에 설치된 가스센서의 출력값으로부터 흡수제의 실시간 흡수효율을 평가하기 위한 연구를 진행하였다. 스크러버 전단과 후단에 설치된 가스센서는 센서표면에서의 가스 흡 탈착반응으로 발생되는 전기적인 변화를 출력신호로 나타내는 측정장치이며, 스크러버의 흡수제와 암모니아 가스와의 반응시간(3시간, 6시간 및 12시간)에 따른 암모니아 가스의 흡수량을 산출하였다. 또한 가스센서의 출력값으로부터 산출된 암모니아 흡수량을 기존의 암모니아 분석방법인 인도페놀법에 의한 흡수량 산정방법과 비교해 보았으며, 약 20%의 차이를 보이긴 하나 0.99 이상의 높은 상관성을 보이고 있음을 확인하였다. 또한, 반응시간에 따른 pH와 흡수량과의 높은 상관성을 확인할 수 있었으며, 흡수제에 대한 암모니아 흡수량을 실시간으로 파악함으로써 흡수제의 파과시간을 예측할 수 있었다. 향후 다양한 연구를 통하여 악취배출시설의 스크러버에 이와 같은 가스센서를 적용하여 흡수제의 흡수 효율을 실시간으로 평가하여 교체주기 및 효율 등을 실시간으로 평가할 수 있는 시스템으로 발전이 가능함을 확인하였다.

습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성 (SOx and NOx removal performance by a wet-pulse discharge complex system)

  • 박현진;이환영;박문례;노학재;유정구;한방우;홍기정
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.

불화수소 누출사고 비교를 통한 하역작업장의 안전성 향상방안에 관한 연구 (A Study on the Improvement of Safety of Unloading Site by Comparison of Hydrogen Fluoride Leakage Accident)

  • 우종운;신창섭
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.32-38
    • /
    • 2018
  • 본 연구는 불화 수소 탱크 컨테이너 하역장에서 불화수소 누출 시 누출량 및 확산 정도를 정량적으로 평가하여 동종사고의 재발을 방지하고 안전성 향상방안을 제시하는데 목적이 있다. 2012년 H사에서는 최대 저장량이 18 Ton인 탱크컨테이너에서 누출사고가 발생하여 인근 지역으로 8 Ton이 누출되었고, 그로인해 사회적 이슈가 되었다. 가우시안 플럼(Gaussian plume) 모델을 이용하여 계산한 결과 누출지점으로부터 반경 1,321m까지의 농도가 20ppm 이상으로 예측되었다. 2014년 R사에서 발생한 불화수소 누출사고에서는 누출량이 11.02kg으로 추정되었고, 그 중 2.9kg이 세정기로 회수되었다. 가우시안 플럼 모델을 사용하여 계산 한 결과, 누출 원으로 부터 20ppm 이상의 농도를 갖는 피해 범위가 반경 69m로 예상되었다. 위의 두 가지 사고를 비교 한 결과, 누출량은 약 987배 차이가 발생했고, 피해 지역은 19 배 이상 차이가 나는 것으로 나타났다. 따라서 보호구의 착용, 하역 장소의 밀폐 및 세정기 설치, 그리고 비상훈련을 실시하여 하역장에서 불화수소가 대량으로 누출되는 사고가 발생하지 않도록 관리해야 한다는 결론을 얻었다.

과산화수소 광분해를 이용한 선박 배가스 내 NO 산화흡수에 관한 연구 (Oxidation and Removal of NO Emission from Ship Using Hydrogen Peroxide Photolysis)

  • 이재화;김봉준;전수빈;조준형;강민경;오광중
    • 청정기술
    • /
    • 제23권3호
    • /
    • pp.294-301
    • /
    • 2017
  • 선박 배가스 오염물질에 대한 규제가 강화됨에 따라 한정적인 공간 내에 복합 오염물질을 제어하기 위한 기술로써 습식흡수법은 다양한 오염물질을 동시에 제거할 수 있는 장점을 가지고 있으나 일산화질소의 낮은 용해도로 인한 한계점을 가지고 있다. 따라서 본 연구에서는 일산화질소를 이산화질소로 산화시켜 용해도를 높임으로써 흡수효율을 증대시키는 방안으로 자외선-과산화수소 산화법을 적용하였다. 자외선을 투사하여 생성되는 수산화라디칼의 양자수율과 과산화수소의 광분해속도는 8 W, 2 M의 최적조건에서 각각 0.8798, $0.6mol\;h^{-1}$이며, 1000 ppm 일산화질소의 산화효율은 2 M 과산화수소, 체류시간 3 min의 최적조건에서 40%로 나타났다. 회분식 반응기에서 일산화질소 가스의 제거효율은 100, 300, 500, 1000, 1500 ppm으로 초기농도가 증가함에 따라 각각 65.0, 65.7, 66.4, 67.3, 68.1%로 제거효율이 증가하는 것으로 나타났다. 따라서 본 연구에서 제안하는 산화기술은 습식흡수공정과 연계를 통해 선박 후처리장치로 적용할 수 있다.

3MWth급 순환유동층 바이오매스 가스화기의 운전에서 Equivalence ratio 영향 (Effect of equivalence ratio on operation of 3MWth circulating fluidized bed for biomass gasification)

  • 박성범;이정우;송재헌;박대원
    • 한국응용과학기술학회지
    • /
    • 제34권1호
    • /
    • pp.58-65
    • /
    • 2017
  • 유동층가스화기는 경제적으로 기술적으로 입증된 기술로서 가장 상용화에 가까운 가능성을 보여주고 있다. 그러나 한국에서는 설계, 현장문제 해결뿐 아니라 파일럿 규모의 설비 운전 등이 부족하여 상용화에 이르지 못하고 있다. 본 연구에서는 바이오매스의 가스화를 위하여 3 MWth 급 순환유동층(CFB) 반응기를 개발하여 운전하였다. 유동층반응기는 순환유동층 반응기와 기포유동층 반응기로 구성되었으며 타르와 산성가스를 제거하기 위하여 세라믹필터, 급속냉각, 습식스크러버를 사용하였다. 3MWth 급 바이오매스 가스화기의 최적 운전조건을 도출하기 위하여 equivalence ratio에 따른 영향을 조사하였다

아크 플라즈마를 이용한 과불화합물 처리공정에서 반응가스에 의한 효과 (Effect of Reaction Gases on PFCs Treatment Using Arc Plasma Process)

  • 박현우;최수석;박동화
    • 청정기술
    • /
    • 제19권2호
    • /
    • pp.113-120
    • /
    • 2013
  • 화학적으로 안정한 과불화합물을 처리하기 위해서는 많은 양의 에너지를 필요로 한다. 이러한 단점을 극복하기 위해서 저전력 아크 플라즈마 시스템을 개발하였다. 분해대상은 $CF_4$, $SF_6$, $NF_3$가 플라즈마 토치로 직접 주입되었으며, 아크 플라즈마 토치의 열효율을 측정하여 실출력을 계산하였다. 실출력과 폐기체 유량 변화 그리고 추가적인 반응가스에 의한 분해효율을 확인하였다. 또한 열역학적 평형조성 분석을 수행하여 실험 결과와 비교하였다. 토치의 열효율은 60~66%의 결과를 보였으며 폐가스 유량이 증가함에 따라 분해효율이 감소하였고 입력전력이 늘어남에 따라 분해효율이 상승되었다. 추가적인 반응 가스가 없이 $CF_4$, $SF_6$, $NF_3$의 분해효율은 입력전력이 3 kW, 폐가스 유량이 70 L/min인 조건에서 각각 4, 15, 90%를 보였다. 반응가스로 산소와 수소를 이용하여 분해효율을 급격하게 증가시킬 수 있었으며, 실험 결과 산소보다 수소를 사용하였을 경우가 분해효율 상승효과와 부산물 제어에 효과적인 것을 알 수 있었다. 수소의 경우, 발생되는 부산물은 불화수소산이었으며 이는 일반적인 습식 스크러버를 이용하여 처리가 용이한 물질이다. 수소를 이용한 화학반응에서 입력전력이 3 kW, 폐가스유량이 100 L/min인 조건에서 $CF_4$가 25%, $SF_6$가 39%, $NF_3$가 99%의 분해효율을 각각 나타냈다.

석유화학공장의 염화수소 누출사고를 통한 대기벤트 시스템의 안전성 향상 방안 (A Study on the Safety Improvement in a Venting System from the HCl Release Accident of a Petrochemical Company)

  • 마병철;이근원;임지표;김영철
    • 한국가스학회지
    • /
    • 제16권4호
    • /
    • pp.38-43
    • /
    • 2012
  • 이 논문은 2008년 5월 H석유화학에서 발생한 염화수소 누출사고에 대한 염화수소 누출량 및 피해범위를 정량적으로 산정하고 예방대책을 제시하는데 그 목적이 있다. 염화수소 Column의 안전밸브를 통해 누출된 양은 안전밸브 배출용량, 이상상태방정식 및 기계적 에너지 수지 식을 사용하여 계산한 결과, 최소한 76.8 kg의 염화수소가 누출된 것을 알 수 있었다. 또한, PHAST 등의 프로그램을 활용하여 안전밸브 설치 지점(높이 24 m)으로 부터 약 350 m 떨어진 곳에서의 염화수소 농도를 예측한 결과, 지표면 누출로 가정하여 계산하는 ALOHA 및 K-CARM 프로그램에서는 각각 304 ppm과 1,700 ppm로 예측되었고 누출 높이에서의 지표면 값을 계산하는 PHAST 프로그램에서는 1 ppm 이하로 예측되었다. 위 결과는, 사고당시 염화수소가 안전밸브를 통해 최소 76.8 kg이 누출되었고 누출지점으로부터 약 350 m 떨어진 곳에 있던 근로자들이 1 ppm 이하의 농도의 HCl 가스에 폭로되었음을 말해준다. 또한, 이러한 사고를 예방하기 위해서는 염화수소와 같은 독성물질은 스크러버 등을 거쳐 세정 후 안전하게 대기로 배출(방출) 시켜야 한다는 사실을 제시한다.