• Title/Summary/Keyword: Gas sampling chamber

Search Result 33, Processing Time 0.025 seconds

A Simplified Closed Static Chamber Method for Measuring Methane Flux in Paddy Soils (논토양(土壤)의 메탄 배출(排出) 측정(測定)을 위한 간역폐쇄정태(簡易閉鎖靜態) Chamber법(法))

  • Shin, Yong-Kwang;Lee, Yang-Soo;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • Various factors such as sampling height in the chamber, sampling interval, sampling time at daytime and the effects of pedoturbation on methane emission during chamber installation were evaluated using a simplified closed static chamber method to measure methane flux in paddy soils. Sampling height of the chamber for representative samples was 65cm. An additional DC fan was required to attain an even methane gradient in the chamber. Considering the change of methane concentration and air temperature in the chamber, sampling is recommended to finish within 30 minutes after starting sampling. The aim of setting DC fan in the chamber was to get the thermal equilibrium in the chamber as well as the representative samples. Suitable time to collect the gas samples representing the day's methane flux was 0900~1200 hours. Gas sampling was possible even after installation of small chambers if the elapsed time was more than 6 hours and supporting stand would be to be added to minimize pedoturbation.

  • PDF

The Differences of Nitrous Oxide (N2O) Emissions as Crop Presence and Location of Gas Sampling Chambers in Upland (밭토양에서 챔버 위치와 작물체 유·무에 따른 아산화질소 배출량 차이 분석)

  • Jeong, Hyun Cheol;Choi, Eun Jung;Lee, Jong Sik;Kim, Gun Yeob;So, Kyu Ho
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.427-432
    • /
    • 2016
  • Nitrous oxide is one of the main sources of greenhouse gases and its concentration has increased from 273 ppb in 1,750 to 315 ppb in 2005. Specially, nitrogen fertilizer used in agricultural soils is considered as an important source of atmospheric $N_2O$ emission. This study was conducted to estimate the difference of nitrous oxide emission as chamber position on furrow and ridge and crop existence in gas sampling chamber on upland. Four treatments used in this experiment were (1) no-fertilizer without crop in chamber on ridge, (2) fertilizer application without crop in chamber on ridge, (3) fertilizer application with crop in chamber on ridge, (4) fertilizer application without crop in chamber on ridge and furrow. Nitrous oxide emission at fertilizer application with crop in chamber on ridge were the highest while were the lowest at no-fertilizer without crop in chamber on ridge. There was no significant difference of nitrous oxide emission by chamber position, but total emission by crop existence in chamber was significant difference. Therefore, in order to estimate greenhouse gases emission using chamber method in upland, it should be considered in correlation with crop existence in chamber and characteristic changes like as the soil moisture, microbial flora by crop growth stage.

NUMERICAL ANALYSIS OF A SAMPLING MODULE FOR A FAST RESPONSE EXHAUST GAS ANALYZER

  • Kim, W.S.;Lee, J.H.;Yoo, J.S.;Rhee, B.O.;Park, J.I.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.149-154
    • /
    • 2007
  • The engine behavior in a transient condition is important to not only emission regulations but also fuel economy. A fast response gas analyzer can be a useful tool to investigate exhaust gas in a transient operation. It should be designed to analyze gas concentration with a short time constant by a fast sampling module and an appropriate measuring method for each emission element. In this study, a new fast sampling module is introduced and flow analysis is performed by numerical simulation. The analysis has shown the proper operating condition and the sensitivity of the module for practical application. Calculated flow to the sampling module has $0.5{\sim}4%$ error, while backflow toward the expansion tube is expected when pressure in CP (Constant Pressure) chamber is over 0.6 bar. For a stable supply of flow to the optical cell, sample gas pressure should be in the range, $0.35{\sim}1.90$ bar, when the pressure in the CP camber and the optical cell are 0.2 bar and 0.158 bar, respectively.

An experimental study on the mechanism of hydrocarbon emissions (배기 Hydrocarbon의 생성과정에 과한 실험적 연구)

  • 심현성;박찬준;이대운
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.25-31
    • /
    • 1991
  • The formation process of hydrocarbon emissions was investigated in SI engine. The time- resolved concentrations of hydrocarbon emissions were measured using a high gas sampling valve and a gas chromatography. The gas was sampled at exhaust port, or the position of spark plug, or the wall of combustion chamber. The experiments were conducted using the Alpha engine of Hyundai Motor Company. The fuel used was methanol or propane. It was found that the effect of the quenching layer of combustion chamber wall on hydrocarbon emissions was not significant. The increasing rate of hydrocarbon concentration at combustion chamber wall near crevice and oil layer after flame was reached was much higher than that at the position of spark plug. The hydrocarbon concentrations at exhaust port had two peak values just after opening exhaust valve and just before closing it.

  • PDF

Methods for Measurement of Methane and Nitrous Oxide Emissions from Agricultural Fields (경작지(耕作地)에서 메탄 및 아산화질소(亞酸化窒素) 배출량(排出量) 측정방법(測定方法))

  • Shin, Yong-Kwang;Kim, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.3
    • /
    • pp.359-372
    • /
    • 1994
  • A simplified closed static chamber method was devised for measurement of methane flux from paddy fields. Compared to automatic methane measuring system(AMMS) this chamber method provides availability with moderate costs of setup and maintenance, while it also provides the time-effectiveness compared to other closed top-type chamber method. It accomodates 30 chambers within 2 hours sampling period with two persons. And it provide a rapid and accurate analysis of methane, 30-40 samples per hour. Modified method for $N_2O$ measurements provides a precise and accurate analysis of nitrous oxide without upgrading additional heating zones for gas sampling(switching) valves.

  • PDF

Measurement Uncertainty of Methane Concentrations from a Rice Paddy Measured by a Closed Automated Chamber System (벼논에서 폐쇄형 자동 챔버 시스템으로 측정한 메탄 농도에 대한 요인별 측정 불확도 비교)

  • Ju, Ok Jung;Kang, Namgoo;Lim, Gap June
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.228-236
    • /
    • 2020
  • BACKGROUND: The closed chamber method is the most commonly used for measuring greenhouse gas emissions from rice fields. This method has the advantages of being simple, easily available and economical. However, a measurement result using the chamber method is an estimated value and is complete when the uncertainty is estimated. The methane emissions from a rice paddy account for the largest portion of the greenhouse gas emissions in the agriculture sectors. Although assessment of uncertainty components affecting methane emission from a rice paddy is necessary to take account of dispersion characteristics, research on these uncertainty components is very rare to date. The goal of this study was to elucidate influencing factors on measurement uncertainty of methane concentrations measured by a closed automated chamber system from a rice paddy. METHODS AND RESULTS: The methane sampling system is located in the rice paddy in Gyeonggi-do Agricultural Research and Extension Services (37°13'15"N, 127°02'22"E). The primary measurement uncertainty components influencing methane concentrations (influencing factors) investigated in this research were repeatability, reproducibility and calibration in the aspects of methane sampling and analytical instrumentation. The magnitudes of the relative standard uncertainty of each influencing factor were quantified and compared. CONCLUSION: Results of this study showed what influencing factors were more important in determination of methane concentrations measured using the chamber system and analytical instrumentation located in the monitoring site. Quantifying the measurement uncertainty of the methane concentrations in this study would contribute to improving measurement quality of methane fluxes.

Analysis of Flow Character and Gas Measurement from Final Cover Soil of sanitary Landfill (쓰레기 매립지 최종 복토층에서 가스 측정방법과 유출특성 해석)

  • 이해승
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.75-86
    • /
    • 1998
  • This paper is going to show the way we can sample the landfill gases flowing out to the air through final cover soil by using an closed chamber in the field for a short time. In addition, we came to the following results through the application of model with actual measurements. 1) Analyzing changes of concentration in the chamber(H: 10-30cm) every 5 minutes, considering analysis time of gas chromatograph for an half hour. 2) The proportion of $CE_4$to $CO_2$changes rapidly near the surface of final cover soil by the influence of methane oxidation reaction. 3) When flux of landfill gas is F=$10^{-5}$mol/$\textrm{m}^2$.s), methane oxidation reaction has an influence on composition of gases, however there is little influence when F=$10^{-6}$ mol/($\textrm{m}^2$.s).

  • PDF

Measurement Uncertainty of Nitrous Oxide Concentrations from a Upland Soil Measured by an Automated Open Closed Chamber Method (밭토양에서 폐쇄형 자동 챔버법으로 측정한 아산화질소 농도에 대한 측정 불확도)

  • Ju, Ok Jung;Kang, Namgoo;Lim, Gap June
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.237-245
    • /
    • 2020
  • BACKGROUND: The closed chamber method is the most commonly used for measuring greenhouse gas emissions from upland fields. This method has the advantages of being simple, easily available and economical. However, uncertainty estimation is essential for accurate assessment of greenhouse gas emissions and verification of emission reductions. The nitrous oxide emissions from upland field is very important for the nitrogen budget in the agriculture sectors. Although assessment of uncertainty components affecting nitrous oxide emission from upland field is necessary to take account of dispersion characteristics, research on these uncertainty components is very rare to date. This study aims at elucidation of influencing factors on measurement uncertainty of nitrous oxide concentrations measured by an automated open closed chamber method from upland field. METHODS AND RESULTS: The nitrous oxide sampling system is located in the upland field in Gyeonggi-do Agricultural Research and Extension Services (37°13'22"N, 127°02'22"E). The primary measurement uncertainty components influencing nitrous oxide concentrations (influencing factors) investigated in this research are repeatability, reproducibility and calibration in the aspects of nitrous oxide sampling and analytical instrumentation. The magnitudes of the relative standard uncertainty of each influencing factor are quantified and compared. CONCLUSION: Results of this study show what influencing factors are more important in determination of nitrous oxide concentrations measured using the automated open closed chambers located in the monitoring site. Quantifying the measurement uncertainty of the nitrous oxide concentrations in this study would contribute to improving measurement quality of nitrous oxide fluxes.

Generation and Decay Phenomena of Environmental Tobacco Smoke in Controlled Experimental Atmosphere Chamber (환경이 조절되는 Chamber 내에서 Environmental Tobacco Smoke의 생성과 감소 현상)

  • 이문수;나도영;안기영;이규서
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.18 no.2
    • /
    • pp.170-176
    • /
    • 1996
  • This paper describes the generation and decay phenomena of gas, vapor and particulate phase components of environmental tobacco smoke in 18 m3 controlled experimental atmosphere chamber. Real time-weighted average concentration ratios of markers were determinated at no ventilation rates and sampling durations of starting to smoking 45 min. Average concentration of major ETS markers was no significant on the mainstream smoke contents of commercial cigarette and decay ratios were dependent on first order kinetic. RSP/nicotine, solanesol and 3-EP were good predictors of ETS concentration in the public indoor field. The concentration ratio of vapor phase and particulate phase components is highly variable to assessment of indoor air quality with ETS. Key words : ETS, chamber study, ETS markers.

  • PDF

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).