• Title/Summary/Keyword: Gas safety check

Search Result 55, Processing Time 0.021 seconds

중수로 환형기체 계통의 방사능 inventory 평가

  • Kim, Jin-Tae;Kang, Deok-Won;Son, Uk
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.90-95
    • /
    • 2003
  • Chemical management of annulus gas system is carried out for the purpose of ensuring the safety and reliability of the system via securing the integrity of the system, detecting the D$_2$O in-leakage of coolant and/or moderator, and reducing the radiation dose. Since the quality of CO_2$ gas, which is used as a filling gas for annulus gas system at CANDU plants, has a propound effect on the integrity of the system material and the radiation dose, CO_2$ gas of high quality is needed. If the quality of CO_2$ gas does not meet the specification, it may give rise to undesirable effect not only on the annulus gas system, but also on the environment due to the production of radioactive nuclei. Therefore, it is very important to check the impurities of CO_2$ gas. Based on this background, the inventories of C-14 and Ar-41 in CO_2$ gas that is supplied as annulus gas were estimated using the data on concentrations of the impurities of $CO_2$ such as C, N_2$ and Ar. The results of this study is expect to give useful information on optimization of CO_2$ impurities maintenance and management of gaseous radioactive wastes produced at CANDU plants.

  • PDF

Numerical Investigation on Experiment for Passive Containment Cooling System (피동 원자로건물 냉각계통 실험에 관한 수치적 연구)

  • Ha, Hui Un;Suh, Jung Soo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.96-104
    • /
    • 2020
  • The numerical simulations were conducted to investigate the thermal-fluid phenomena occurred inside the experimental apparatus during a PCCS, used to remove heat released in accidents from a containment of light water nuclear power plant, operation. Numerical simulations of the flow and heat transfer caused by wall condensation inside the containment simulation vessel (CSV), which equipped with 18 vertical heat exchanger tubes, were conducted using the commercial computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the wall condensation model were used for turbulence closure and wall condensation, respectively. The simulation using the actual size of the apparatus. However, rather than simulating the whole experimental apparatus in consideration of the experimental cases, calculation resources, and calculation time, the simulation model was prepared only in CSV. Selective simulation was conducted to verify the effects of non-condensable gas(NC gas) concentration, CSV internal pressure, and wall sub-cooling conditions. First, as a result of the internal flow of CSV, it was observed that downward flow due to condensation occurred surface of the vertical tube and upward flow occurred in the distant place. Natural convection occurred actively around the heat exchanger tube. Due to this rising and falling internal flow, natural circulation occurred actively around the heat exchanger tubes. Next, in order to check the performance of built-in condensation model using according to the non-condensable gas concentration, CSV internal flow and wall sub-cooling, the heat flux values were compared with the experimental results. On average, the results were underestimated with and error of about 25%. In addition, the influence of CSV internal pressure and wall sub-cooling was small, but when the condensate was highly generated due to the low non-condensable gas concentration, the error was large compared to the experimental values. This is considered to be due to the nature of the condensation model of the CFX code. However, in spite of the limitations of CFD, it is valid to use the built-in condensation model of CFD for PCCS performance prediction from a conservative perspective.

A Study on the Feasibility of Applying Solar Power Generation Systems to Merchant Ships for Energy Saving (에너지 절감을 위한 태양광 발전시스템의 선박 적용 타당성 연구)

  • Kim, Kyunghwan;Jeon, Hyeonmin;Kim, Seongwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1067-1073
    • /
    • 2021
  • Regulations to reduce greenhouse gas emissions from ships are gradually being strengthened. EEXI (Energy Efficiency Existing Index) has been introduced in existing ships, and various studies are aimed at achieving the greenhouse gas emission reduction target are currently underway. In this study, we proposed a method to reduce greenhouse gas emissions through reducing fuel oil consumption by applying a solar power generation system to a pure and truck carrier among existing ships engaged in international voyages. The proposed photovoltaic power generation system consists of a photovoltaic module, an energy storage system, and a power conversion device. To confirm applicability, the system was modeled through a power electronics program, and a simulation was performed. In addition, economic analysis was conducted to check the feasibility of application to real ships, and it was confirmed that significant results were derived in the economical aspect after about 11 years had elapsed.

A Study on Damage Effects Assessment for Asphyxiation Accident due to Malfunction of Gas Type Fire Extinguishing System (가스계 소화설비 오작동으로 인한 질식사고의 피해영향 평가)

  • Kim, Eui-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.36-43
    • /
    • 2020
  • Gas system fire extinguishing equipment is a very economically useful facility, but if it is not used for a long period of time after installing the equipment, there is possibility of rupture due to corrosion of containers and operation errors of equipment systems, and this is very dangerous. However, it is impossible to experiment to check whether the equipment is operating normally. If gas is temporarily released into the enclosed space due to rupture and malfunction, it can cause serious human damage due to gas suffocation. In this study, based on the suffocation death accident of gas system fire extinguishing facility, the inflow path of released gas and the possibility of death and time to death were estimated using a 3D scan and FLACS.

Prediction of the Blast Wave Propagation Over a Kick Motor Test Facility (Kick Motor 시험장 충격파 전파 예측)

  • Ok, Ho-Nam;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.220-223
    • /
    • 2008
  • A test facility to measure the performance of a KM(Kick Motor) is constructed, and prediction of blast wave propagation over the facility is performed to check if the safety of test personnel in MCC(Main Control Center) can be guaranteed even for the most severe explosion. Assuming that the initial explosion energy is contained in a sphere under the pressure of 500, 1000, 1500 psi, respectively, the radius of the sphere is determined for each pressure to set the mass of contained explosion gas to 35 kg. The material properties of explosion gas are set to be the ones of KM propellant combustion gas under normal condition. To reduce the effort and time required for a complex three-dimensional modeling, the flowfield is approximated to axismmetry. Calculations are performed for all three initial pressure conditions, and the analysis of the result is given for 1500 psi which is expected to be the worst case. The maximum pressure is 3.5 psig while the minimum pressure is -1.2 psig on the outer wall of MCC, and the maximum pressure difference between the inner and outer walls of protection wall amounts to 3.0 psi.

  • PDF

A Study on Optimal Operation for Flare systems (플레어 시스템의 최적 운영방안에 대한 연구)

  • Song, Bang-Un;Bok, Hyeong-Jun;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.1-7
    • /
    • 2019
  • Most oil refineries and chemical plants have flare systems designed to mitigate pressure rises in process facilities in case of emergencies that require the release of large amounts of gas due to sudden process shutdowns such as power outages. However, the rise of the flame of the flare system causes civil complaints from residents around the factory due to visible pollution, and economic loss occurs in the company, which requires constant management. In this study, two items were diagnosed and analyzed in order to derive the optimal operation method of flare system. First, to detect the cause of the rise in flame height, the acoustic leak detector was used to check gas leaks in safety valves and pressure control valves. Second, to identify the cause of flame instability, the pulsation phenomenon was diagnosed through the CFD simulation and modeling experiments of the sealing drum. By confirming the leak at 4.3% of the safety valve and 10% of the pressure control valve, the cause of abnormal sparking was derived. The information presented in this study can be easily applied to any company that has a flare system, and is expected to prevent complaints and product loss.

A Vibration Test of Fuel Tanks for LNG Vehicles (액화천연가스 차량용 연료탱크의 진동시험)

  • Choi, Myung-Jin;Cho, Tae-Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.67-71
    • /
    • 2015
  • Natural frequencies of a cryogenic fuel tank of LNG vehicle were computed to check the safety related to the resonances, and tests were performed to confirm the vibrational durability of a cryogenic fuel tank. There were 3 tests. The first test started at excitation frequency of 31.9Hz, and the test was performed reducing the excitation frequencies. Failure took place at 22.1Hz. The second test was performed with the frequencies to be increased. At 12.7 Hz, failure took place and nitrogen gas was exhausted. In the third test, the excitation frequencies were continuously changed, and the vibration port was failed in the range between 8 Hz and 19.3 Hz. Detailed research on the failed parts of the tank in this study is recommended to enhance the safety of the cryogenic fuel tanks of LNG vehicles.

A Case Study and Analysis of the Causes for Natural Gas Vehicle Accidents (천연가스자동차 사고사례 및 원인분석)

  • Kim, Young-Seob;Cho, Eun-Goo;Kim, Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.41-48
    • /
    • 2009
  • I collected the cases of CNG vehicle accidents which had happened for 30 years and analyzed the causes of the accidents according to each type of cylinders. There are about six accidents including three cylinder explosion accidents due to bad heat treatment, one composite damage, one CNG vehicle fire, and one fuel piping accident owing to the poor maintenance. When looking into the cylinder types involved in the accidents and the causes, 29% of the cylinder accidents are Type I and 24% Type IV, 16% Type II, and 14% Type III. 37% of the accidents are caused by the defects of the raw materials and the errors of a manufacturing process, 16% by the stress corrosion cracking as a result of the repetitive use, 15% by the cylinder's explosion on account of the malfunction of PRD(Pressure Relief Device) and the overpressure. The remainders of the causes are fire and unknown causes. Therefore, cylinder manufacturers have to strengthen quality management of raw materials and manufacturing process and painting regardless of each type of cylinder. Also bus operators need to make an effort to keep safety condition through every day check.

  • PDF

A Study on Systematic Risk Assessment Method for LNG Storage Facilities (LNG 저장설비에 대한 체계적인 위험성평가 방법에 관한 연구)

  • Kang, Mee-Jin;Lee, Young-Soon;Lee, Seung-Rim
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • As the consumption of LNG has increased, the capacity and number of LNG facilities are getting bigger and bigger. Such circumstances supports the need for a dedicated risk analysis model to help review and check major issues of the safer construction and operation of LNG storage facilities systematically. Therefore this study suggests an appropriate risk analysis model that enables us to evaluate hazards of LNG storage facilities more easily and systematically, and then to use its result in siting, design and construction stages of the facilities. ill order to develop the model, lots of existing studies and domestic and foreign codes and standards were fully reviewed and a series of case studies also were carried out. The suggested model consists of 4-stage evaluations: in selecting a site, in determining a layout, in designing and constructing the facilities, and in operating them. This model also suggests the weather condition necessary for estimating the consequence of accident-scenarios, and the easy, systematic approach to the analysis of their probability. We expect that the model may help secure LNG storage facilities' inherent safety in determining their site and layout.

  • PDF

Rheological behavior study of Marine Lubricating oil on the amount of MGO (Marine Gas Oil) dilution (해상용 경유의 희석량에 따른 선박용 윤활유의 유변학적 거동연구)

  • Song, In Chul;Lee, Young Ho;Yeo, Young Hwa;Ahn, Su Hyun;Kim, Dae il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.2
    • /
    • pp.240-245
    • /
    • 2016
  • This paper describes the rheological behavior study such as viscosity and change of shear stress regarding marine lubricating oil according to the amount of Marine Gas Oil (MGO) dilution. The viscosity reduction due to fuel dilution is crucially important characteristic to decreasing engine durability because of the abrasion of piston ring or liner. The lubricating oil used in this paper was blended with magnetic stirrer diluted High Sulfur Diesel (HSD, 0.05 wt%) ratio of 3 %, 6 %, 10 %, 15 % and 20 %. The viscosity and shear stress of diluted lubricating oil were measured with the temperature range from $-10^{\circ}C$ to $80^{\circ}C$ using a rotary viscometer (Brookfield Viscometer). As the amount of MGO dilution increasing in lubricating oil, the viscosity and stress of those decreased, because the lubricating oil diluted MGO with low viscosity show the trends to decreased viscosity and shear stress. Especially, the viscosity and shear stress of lubricating oil radically decreased at low temperature ($0{\sim}-10^{\circ}C$) and doesn't effect in MGO dilution at over $40^{\circ}C$. As temperature risen, the reduction of the viscosity and shear stress in lubricating oil shows the Newtonian behavior. The lubricating oil was required to check up periodically to improve engine durability since the viscosity reduction by MGO dilution accelerating the engine abrasion.