• 제목/요약/키워드: Gas removal efficiency

검색결과 558건 처리시간 0.03초

2단 정전식 세정집진기의 집진 및 가스제거 특성 (An Experiment on Particle Collection and Gas Removal in a 2-Stage Electrostatic Wet Scrubber)

  • 여국현;유경훈;손승우;김윤신
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.745-752
    • /
    • 2006
  • DOS and NaCl aerosol particles were used to determine collection efficiencies of a 2-stage electrostatic wet scrubber with respect to particle size. The DOS and NaCl aerosols have geometric mean diameters of 0.1-3.0 urn, geometric standard deviations of $1.1{\sim}1.8$ and total number concentrations of $450{\sim}2,400\;particles/cm^3$. The tested operating variables for the electrostatic wet scrubber included air velocity and water injection rate. It was shown from the experimental results that particle collection efficiencies increased in the submicron particle size range when different polarities were applied on the water nozzle and corona wire, respectively. This increase in the collection efficiency is attributed to strong electrostatic attraction between the negative water droplets and positive submicron particles. The collection efficiencies also increased when water injection rate was increased or air velocity was decreased. Meanwhile, the pressure drop across the wet scrubber decreased by 90% compared with the existing mechanical wet scrubber. Finally, ammonia gas was used to determine gas removal efficiencies. It was observed that the gas removal efficiencies increased when the air velocity was decreased or the water injection rate was increased.

Removal of Dissolved Oxygen from the Make-up Water of NPP Using Membrane-based Oxygen Removal System

  • Chung, Kun-Ho;Kang, Duck-Won;Hong, Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.541-547
    • /
    • 1999
  • Corrosion control, in the end-shield cooling system of Wolsung Nuclear Power Plant, is directly related to the control of dissolved oxygen (DO). The current method, being used to deoxygenate the end-shield cooling water, is a chemical treatment by addition of reducing agent, hydrazine, to react with DO. This method has several limitations including high reaction temperature of hydrazine , unwanted explosive hydrogen gas production, and its intrinsic harmful property. A new approach to remove DO using a membrane-based oxygen removal system (MORS) was tried to overcome limitations of the hydrazine treatment. The DO removal efficiency of the MORS was found to be in the range 87% to 98%: The higher vacuum, the lower water flow rate and the higher water temperature tend to increase the DO removal efficiency.

  • PDF

순산소연소 조건에서 Drop tube furnace를 이용한 운전변수에 따른 석회석의 탈황특성 연구 (Study on the Desulfurization Characteristic of Limestone Depending on the Operating Parameters of In-Furnace Desulfurization for Oxy-Fuel Combustion Using Drop Tube Furnace)

  • 최욱;조항대;최원길;박영성;길상인;이형근
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.857-864
    • /
    • 2011
  • 순산소연소는 높은 연소 효율과 적은 배가스량, 낮은 질소산화물 농도를 장점으로 하고 있으며 연소온도 조절을 위한 배가스 재순환에 의해 배출되는 연소가스중의 $CO_2$ 농도를 95%까지 농축이 가능하므로 석탄 연소설비에 대한 유망한 CCS 기술로 부각되고 있다. 본 연구는 순산소연소 조건에서 배가스의 재순환을 통한 $CO_2$ 농도 증가에 기인하는 직접 황화반응이 탈황효율에 미치는 영향을 평가하고 반응온도, $CO_2$ 농도, $SO_2$ 농도상승이 $SO_2$ 제거효율에 미치는 영향과 배가스 중 수분 등이 $SO_2$ 제거효율에 미치는 영향을 실험적으로 고찰하였다. 반응온도 $1,200^{\circ}C$까지 온도 상승에 따라 $SO_2$의 제거효율은 증가하였고 Ca/S비, $CO_2$ 농도와 수분이 증가할수록 $SO_2$ 제거효율이 증가하였다. 이러한 운전변수는 영향인자 평가를 통하여 Ca/S 비>체류시간>$O_2$농도>반응온도>$SO_2$농도>$CO_2$농도>수분농도의 순으로 탈황반응에 영향을 미치는 것으로 나타났다. 또한 운전변수별 실험결과를 이용하여 로내 건식탈황에 있어서 각 운전변수별 성능 영향인자를 평가할 수 있는 반경험적 모델식을 도출하였다.

침액식 세정설비의 마이크로버블을 이용한 철강산업 공정의 산세조 발생 염화수소 제거 (Hydrochloric Acid Gas Removal from Iron and Steel Industry Using Micro-bubbles of a Dip Injection Wet Scrubber System)

  • 김예진;정재억;정용준
    • 한국습지학회지
    • /
    • 제17권1호
    • /
    • pp.75-79
    • /
    • 2015
  • 대기오염물질인 염화수소의 배출 규제가 2ppm으로 강화됨에 따라 기존의 제철공장 습식세정 장치에 DIWS 시스템이 도입되었다. 침액식 스크러버 시스템으로 제철공정에서 발생되는 염화수소를 처리하기 위한 파일럿 연구를 수행하였다. DIWS 시스템의 운전에 따른 응축수 pH는 연돌에서 6.0으로 증가하였다. 산세 Fume 정제설비의 평균 유입 염화수소는 13.3ppm, 평균 배출가스는 0.43ppm, 평균 제거율은 96.9%로 나타났다. TMS 장치로 장기간 측정한 데이터를 비교하였을 때 DIWS 장치는 안정적인 제거율을 나타냈지만, TMS의 type별 데이터 불균일 현상이 관찰되었다.

가스 크로마토그래피에 의한 주방용 합성세제와 알콜소독제의 잔류농약 제거효과 분석 (Analysis of Removal Efficiency of Pesticide Residue on Dishwashing Detergent and Alcoholic Disinfectant by Gas Chromatography)

  • 이재덕;조윤진;이만호;정우원
    • 공업화학
    • /
    • 제9권7호
    • /
    • pp.985-989
    • /
    • 1998
  • 본 연구는 가스크로마토그래피를 이용하여 사과와 고추에 대해 물, 주방용합성세제, 살균소독제 등의 다양한 세척제에 의한 농약의 세척 제거효율을 조사하였다. 농약의 회수율을 높이기 위해 대상 농약별로 상이한 전처리 조건으로 실험하였고 최적의 전처리 조건을 조사하였다. 분리관은 supelco STB-608을 사용했고 검출기로 전자포획검출기(ECD)를 사용했다. 농약제거효율은 알콜소독제>주방용합성세제>물 순서로 높았다.

  • PDF

축산환경 개선을 위한 암모니아 제거 미생물의 탐색 및 분리 (Screening and Isolation of Ammonia Removal Microorganism for the Improvement of Livestock Environment)

  • 이소진;이은영
    • 한국미생물·생명공학회지
    • /
    • 제37권4호
    • /
    • pp.408-412
    • /
    • 2009
  • A study on the screening and isolation of microorganism was performed for the removal of main malodor, such as ammonia, produced from the livestock farm. The main malodor components in livestock farm are ammonia, volatile fatty acids, sulfur compounds and trimethylamine. Damages to man and livestock were originated from malodors mainly due to ammonia, and thus ammonia reduction experiments were performed. Sludge of sewage treatment plant was inoculated in the sesame dregs culture, from which ammonia gas was produced. An aerobically grown, pure cultured isolated from the 10th enrichment culture was analyzed by 16S rRNA sequencing and identified as Alcaligenes sp. NS-1. This strain NS-1 precultured in the sesame dregs was found to remove ammonia gas with an efficiency of approximately 99-100% at an average concentration of 40 ppmv of ammonia gas. When the strain NS-1 sprayed to pig excrements, the removal efficiency at an average concentration of 100 ppmv of ammonia was approximately 60% after 16 hr.

압력순환흡착법과 다공성 매체 연소법을 이용한 전자산업 불화가스 저감 스크러버 개발 (The Development of Scrubber for F-gas Reduction from Electronic Industry Using Pressure Swing Adsorption Method and Porous Media Combustion Method)

  • 정종국;이기용;이상곤;이은미;모선희;이대근;김승곤
    • 청정기술
    • /
    • 제23권2호
    • /
    • pp.181-187
    • /
    • 2017
  • 반도체 및 디스플레이 산업에서 배출되는 과불화합물은 연소, 열, 플라즈마, 촉매 등의 다양한 방법이 적용된 스크러버에 의해 분해 과정을 거친 후 배출되나, 운영 스크러버의 대부분이 과도한 에너지의 사용, 낮은 저감 효율을 보임으로써 이러한 단점의 극복이 요구된다. 압력순환흡착법과 다공성 매체 연소법의 두 가지 기술이 연계된 새로운 형태의 과불화합물 저감 스크러버를 개발하고 특성을 알아보았다. 분해 대상인 $CF_4$의 흡착비와 손실계수는 흡착 컬럼의 입구와 출구에서 농도 측정을 통해 계산하였으며, 연소기의 입구와 출구의 유량과 농도 측정을 통해 처리 효율을 계산하였다. 기존 스크러버와의 에너지 사용량 및 처리효율 비교를 위하여 다양한 유량에 대한 성능 평가가 진행되었다. 1412 ppm, 204 LPM의 $CF_4$가 유입된 흡착 컬럼에서의 흡착비는 1.65였으며, 유입되는 $CF_4$의 손실 계수는 8.2%였다. 이때 연소기로 유입되는 $CF_4$의 유량과 농도는 각각 91 LPM과 2335 ppm이었으며, $CF_4$ 19 LPM, $O_2$ 40 LPM을 사용한 연소 반응시 약 96%의 저감 효율을 나타내었다. 상용 스크러버와의 동일 운전 조건에서의 다공성 매체 연소에서의 $CF_4$ 저감 효율과 전체 에너지 사용 효율 비교시 각각 16%, 41% 이상의 저감 효율 상승과 에너지 절감 효과를 보였다.

양방향 펄스 전원에 의한 배기가스의 제거 (The Removal of Flue Gas by Using Bidirectional Pulse Generator)

  • 전재룡;성기범;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2224-2226
    • /
    • 1999
  • Non-thermal plasma techniques is applied in many fields. Recently acid rain, global warming, ozone depletion, and smog are preeminent environmental problems. The cause for this environmental problems is the flue gas. Non-thermal plasma techniques has an attention for the solution of flue gas. Non-thermal plasma is used for the removal of flue gas composed of NOx, etc. This field has grown dramatically. This experiment is performed by using cylinder type reactor under the condition of room temperature and atmosphere pressure. NO gas is used instead of flue gas. Bidirectional pulse generator is used instead of the unidirectional pulse generator to increase the efficiency.

  • PDF

세라믹과 유리에 코팅한 TiO2 광촉매를 이용한 가스상 벤젠의 제거 (Photocatalytic Degradation of Benzene in the Gas Phase using TiO2 Coated on Ceramic and Glass Beads)

  • 손현석;양원호;김현용;이소진;박종래;조경덕
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.57-66
    • /
    • 2003
  • TiO$_2$ sol was prepared by sol-gel method, and this sol was coated in ceramic and glass bead by dip-coating method. The coated catalyst was applied to degrade benzene in the gas phase by exposing to UV -lamp (365 nm) in a batch reactor. The removal efficiency of the benzene was compared by changing various conditions such as the kind of chemical additives, the coating beads (ceramic and glass), solution pH, the initial concentration of TiO$_2$ sol, UV intensity, and benzene concentration. The physical structure of TiO$_2$ sol used in this study was found to be pu-rely anatase type from XRD analysis. The results showed that ceramic bead was effective as the coating agent rath-er than glass bead. The significant change in the benzene removal efficiency of benzene did not occur with chang-ing coating frequency and the initial concentration of TiO$_2$ sol. The removal efficiency of benzene increased with increasing UV intensity, and with acidic treatment of TiO$_2$-coated ceramic bead.

DC 저온플라즈마를 이용한 디젤엔진 유해 배기가스 저감에 관한 실험적 연구 (The Experimental Study on the Removal of Diesel Engine Pollutant Emissions Using DC Non-Thermal-Plasma(NTP))

  • 채재우;황재원;정지용;한정희;황화자;김석
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.35-42
    • /
    • 2001
  • The diesel engine exhaust gas is know as one of the causes to produce photochemical smog, which causes damage on environmental. However, due to the high thermal efficiency and low carbon dioxide emission, the usage of a diesel engine is prevailed. In this study, the DC non-thermal plasma technology used to the particulate matter (PM) aftertreatment. The exhaust gas characteristics and energy density were investigated on the dynamometer test bed and chassis dynamometer with CVS-75 mode in a passenger diesel car. It was reported that the smoke removal efficiency has around the 70% in the dynamometer test with 80W energy consumption and the PM removal efficiency has the 68% in the real car test. The NOx also reduced the 20% according to electrode type respectively. Considering these results, plasma technology is one of the ways to simultaneously removing method the particulate matter (PM) and NOx.

  • PDF