• 제목/요약/키워드: Gas removal

검색결과 1,280건 처리시간 0.027초

자계가 인가된 공기청정장치의 가스 제거 특성 (Gas Removal Characteristics of Air Clean System Applying a Magnetic Field)

  • 신수연;문재덕
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.921-925
    • /
    • 2007
  • Gas removal characteristics of an air clean system, consisted of a filter and a nonthermal discharge plasma reactor with a magnetic field, have been investigated with emphasis on the enhancing gas removal efficiency of the applied magnetic field. It is found that the magnetic field influenced significantly to the corona discharge characteristics, decreasing the corona onset voltage and increasing the corona current. As a result, the proposed air clean system with the magnetic field showed the higher removal efficiency of the gas (e.g., trimethlyamine) than that of without the magnetic field. This would be because the magnetic field applied to the discharge plasma reactor of the air clean system can elevate the corona characteristics, and activate the generation of ozone, thus the removal efficiency of the gas was concurrently enhanced. This reveals that the proposed air clean system with the magnetic field could be used as an effective means of removal an indoor pollutant gas.

충진제의 종류에 따른 습식 스크러버의 가스상 물질 제거특성 (Removal Characteristics of Gaseous Contaminants by a Wet Scrubber with Different Packing Materials)

  • 한방우;김학준;김용진;한경수
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.744-751
    • /
    • 2007
  • Wet scrubber is widely used to remove toxic gaseous contaminants in various industries such as semi-conductor industry, display manufacturing industry and so on. In this study, to optimize a packed bed scrubber as one of typical wet scrubber size while keeping its performance, four different packing materials were investigated at different air flow rates, liquid-gas ratios and pH values. Ammonia, hydrochloric acid and hydrofluoric acid were used as test gases to characterize the scrubber performance. Gas removal efficiency increased as the packing size decreased, which resulted in the increase of specific surface area. The increase of air flow rate led to the decrease of gas removal efficiency, while the increase of liquid-gas ratio led to the increase of gas removal efficiency. For the case of $NH_3$ gas, lower pH, and for the cases of HCl and HF, higher pH contributed to higher gas removal efficiency. Gas removal efficiency of a wet scrubber increased in the order of HCl < $NH_3$ < HF according to its water solubility.

산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건 (Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants)

  • 백경렬;구자공
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

반건식 배연탈황법에 의한 연소 페가스 중 $SO_2$제거에 관한 연구 (A Study on $SO_2$Removal in Flue Gas by Semidry Flue Gas Desulfurization Method)

  • 송호철;이윤기;박진원
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.273-280
    • /
    • 1998
  • The investigation on the removal of 502 gas fro.In flue gas which causes serious air pollution was made by using a semi dry flue gas desulfurization method. Experiments were carried out as a function of process variables which would affect SO2 removal efficiency. Process variables inclilded SO2 inlet concentration, inlet temperature of simulated flue gas, sorbent weight fraction, and volume flow rate of sorbent slurry. In this study, used sorbent was Ca(OH), and simulated flue gas was prepared by mixing pure SO2 gas with air. Experimental conditions were varied at 140~18$0^{\circ}C$ of inlet temperature of the simulated flue gas, 500~2000ppm of inlet SO2 concentration, 0.4~1.0% of sorbent concentration, and 10~25 mL/min of flow rate of sorbent slurry. Among process variables, inlet concentration of SO2 was found to be the most significant factor to affect SO2 removal efficiency. The concentration of Ca(OH2) had a lower effect on SO2 removal than SO2 inlet concentration removal amount was 0.108, 0.141, 0.153 g SO2/g Ca(OH)2 respectively- As 200 mmol of HNO3 was added into slurry to improve removal efficiency, initial pH was maintained and solubility of slurry increased, so that removal efficiency elevated. Adding over 200 mmol of HNO3 into slurry caused removal efficiency lower. Therefore it could be concluded the optimum was 200 mmol of HNO3 input.

  • PDF

슬러지반응기에서 팥가공폐수의 철기성 처리 (Anaerobic treatment of red-bean processing wastewater in a sludge bed reactor)

  • 안재동;금재우;홍종향
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.29-37
    • /
    • 1994
  • Anaerobic treatment of wastewater of the red- bean processing industry was carried out and discussed an anaerobic sludge bed reactor( ASBR) as a preliminary study to evaluate applicability of given processes. The dimension of reactor were same as 0.09m- ID$\times $1.5m- height. The type of substrate and the hydraulic retention time( HRT) were considered as experimental variables. The synthetic wastewater with glucose in the laboratory, the wastewater from the red bean processing industry mixed with synthetic wastewater with variation of mixing percent were fed as substrate. The hydraulic retention time was changed from one day to five days. The gas production, the methane content in produced gas, efficiencies of COD removal and 55 removal were evaluated as principal characteristics. With synthetic wastewater as a substrate and at a hydraulic retention time of one day, characteristics of ASBR was the gas production(12$\ell$/day ), the methane content of produced gas(60%), the efficiency of COD removal(92%) and 55 removal(30%). With the real wastewater and at a hydraulic retention time of one day, the gas production and the efficiency of COD removal of the ASBR decreased with the proportion of real wastewater. The gas production and the efficiency of COD removal with real wastewater only was decreased to 70% and 87% of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. With real wastewater only as a substrate in the ASBR, the gas production was decreased with an increase of HRT, but the efficiency of COD removal increased with HRTI like the usual trend reported. As a conclusion, the wastewater of the red- bean Processing industry could be treated by anaerobic digestion successfully in the ASBR.Anaerobic treatment of wastewater of the red- bean processing industry was carried out and discussed an anaerobic sludge bed reactor( ASBR) as a preliminary study to evaluate applicability of given processes. The dimension of reactor were same as 0.09m- ID$\times $1.5m- height. The type of substrate and the hydraulic retention time( HRT) were considered as experimental variables. The synthetic wastewater with glucose in the laboratory, the wastewater from the red bean processing industry mixed with synthetic wastewater with variation of mixing percent were fed as substrate. The hydraulic retention time was changed from one day to five days. The gas production, the methane content in produced gas, efficiencies of COD removal and 55 removal were evaluated as principal characteristics. With synthetic wastewater as a substrate and at a hydraulic retention time of one day, characteristics of ASBR was the gas production(12$\ell$/day ), the methane content of produced gas(60%), the efficiency of COD removal(92%) and 55 removal(30%). With the real wastewater and at a hydraulic retention time of one day, the gas production and the efficiency of COD removal of the ASBR decreased with the proportion of real wastewater. The gas production and the efficiency of COD removal with real wastewater only was decreased to 70% and 87% of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. With real wastewater only as a substrate in the ASBR, the gas production was decreased with an increase of HRT, but the efficiency of COD removal increased with HRTI like the usual trend reported. As a conclusion, the wastewater of the red- bean Processing industry could be treated by anaerobic digestion successfully in the ASBR.

  • PDF

활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석 (Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode)

  • 임기택;김용진;한방우;우창규;신원규;김학준
    • 한국입자에어로졸학회지
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

침엽수를 이용한 암모니아 가스 제거효율 연구 (Study of ammonia-gas removal′s characteristics using wood-material)

  • 박영규
    • 환경위생공학
    • /
    • 제19권2호
    • /
    • pp.7-14
    • /
    • 2004
  • This paper was investigated to clarify the possibility of ammonia-gas removal by essential oil. First of all, the chemical analysis was performed to analyze the composition of an essential oil by GC-MS. The monoterpenes in an essential oil react with ammonia by neutralization and their reaction mechanism was elucidated. Based on their chemical neutralized reaction, the removal efficiencies of ammonia gas were studied to derive the optimal conditions in the scrubber tower such as optimal temperature and pH. The experimental result shows that the removal efficiency of ammonia gas was achieved over 80 % by the misty aerosol dispersion of scrubber tower.

바이오가스 마이크로 터빈 발전용 전처리시스템 전산유동해석 (Computational Fluid Dynamics Analysis of the Pretreatment System for Livestock BIO-GAS MGT Power Generation)

  • 허광범;박정극;임상규;김재훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.260-263
    • /
    • 2008
  • KEPCO(Korea Electric Power Corporation) is performing the nation's first biogas-MGT project as an effort to encourage the utilization of wasted biogas which contains useful CH4. The goals of this project are to develop the Pretreatment system of Livestock bio-gas and set up the biogas-MGT co-generation system. The project will not only utilze flared biogas as precious energy but also improve the economics of the plant a lot. The pretreatment system mainly consists of sulfur removal tower, biogas compressor and many filtering systems. A computational fluid dynamics study in the bio gas sulfur removal tower and sulfur absorption filter was carried out. Understanding of the flow in the sulfur removal tower and sulfur adsorption filter obtained by this study can be used to identify the problems in the sulfur removal tower and to improve the sulfur removal efficiency of the sulfur removal tower. Resistance material modeling is used to simulate the sulfur adsorption filter, and the resistance coefficient was adjusted to reflect the experimental pressure loss value. And the pressure loss change with the flowrate is predicted

  • PDF

MOLECULAR SCALE MECHANISM ON EVAPORATION AND REMOVAL PROCESS OF ADHERENT MOLECULES ON SURFACE BY BURNT GAS

  • Yang, Y.J.;Lee, C.W.;Kadosaka, O.;Shibahara, M.;Katsuki, M.;Kim, S.P.
    • International Journal of Automotive Technology
    • /
    • 제7권2호
    • /
    • pp.121-128
    • /
    • 2006
  • The interaction between adherent molecules and gas molecules was modeled in the molecular scale and simulated by the molecular dynamics method in order to understand evaporation and removal processes of adherent molecules on metallic surface using high temperature gas flow. Methanol molecules were chosen as adherent molecules to investigate effects of adhesion quantity and gas molecular collisions because the industrial oil has too complex structures of fatty acid. Effects of adherent quantity, gas temperature, surface temperature and adhesion strength for the evaporation rate of adherent molecules and the molecular removal mechanism were investigated and discussed in the present study. Evaporation and removal rates of adherent molecules from metallic surface calculated by the molecular dynamics method showed the similar dependence on the surface temperature shown in the experimental results.

복합방전형 오존발생기의 오존생성 및 NO 가스 제거특성 (Ozone Generation and NO Gas Removal Characteristics a Hybrid Discharge Type Ozonizer)

  • 송현직;이상석;신용철;김민회;박찬규;이광식;임창호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.278-280
    • /
    • 2006
  • A hybrid discharge type ozonizer, which is superposed silent and surface discharges, has been designed and manufactured to apply for Nitrogen Oxides(NO) gas removal. The ozonizer consists of three electrodes, and is classified three types of ozonizer by changing applied voltage. Investigation was carried out variance with the flow rate of supplied oxygen gas, discharge power and the sorts of superposed discharge type ozonizer. Moreover, $NO(1200[ppm])/N_2$ gas removal investigation was also conducted to apply for environment improvement field. Two kinds of NO gas removal investigations were conducted. It distinguishes the investigations into NO gas reaction method. According to these studies, maximum removal rate of 100[%] in NO gas was obtained, and 8334[ppm] and 3249[mg/h] of maximum ozone concentration and generation were also obtained respectively.

  • PDF