• 제목/요약/키워드: Gas processing system

검색결과 314건 처리시간 0.026초

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.

이차포장을 통한 유과의 저장성 연장 (Extending the Shelf-life of Yukwa Using Secondary Packaging)

  • 정준재;이근택
    • 한국식품과학회지
    • /
    • 제42권4호
    • /
    • pp.452-458
    • /
    • 2010
  • 본 연구는 유과의 품질과 저장성 향상을 위한 포장기술개선을 목적으로 이차포장의 효과를 확인하기 위하여 실시되었다. 유과의 포장은 단일필름인 OPP(P1)를 사용하여 일차포장을 하였고, 다층접합필름인 OPP/LLDPE(P2), PET/NY/CPP(P3), PET/AL/NY/CPP(P4)를 각각 사용하여 각각 이차포장을 하였다. 포장된 유과는 $25^{\circ}C$에서 12주 동안 저장하면서 품질 변화와 저장수명을 조사하였다. 모든 포장군들 중 산가는 P1에서 1.26 mg KOH/g으로 가장 높은 값을 기록했지만, 저장말기까지 법적 기준치인 2.0 mg KOH/g보다는 낮게 나타났다. 산가는 저장기간 중 계속 증가하였는데 포장재의 투과도가 낮은 이차포장군일수록 증가추세가 완만하였다. 과산화물가는 P3에서 32.91 meq/kg으로 가장 높은 값을 기록하였다. 색의 변화에서는 전반적으로 Hunter 'L'값이 감소하고 Hunter 'a'와 'b'값은 증가하는 경향을 보였으며 저장기간 중 P1에서의 색차가 가장 두드러졌다. 유과의 물성은 각 항목에서 P1은 경도, 검성, 탄력성과 응집성, P2은 부서짐성 품질의 변화가 가장 컸던 것으로 나타났다. 또한 수분차단성이 가장 높은 P4에서 모든 물성의 변화가 가장 낮게 나타났다. 관능검사 시 P1 등을 제외한 이차포장군에서 10주까지도 외형의 변화가 두드러지지 않았음이 관찰되었다. 유과의 조직감을 결정하는 수분함량은 5%이하로 감소되면 관능검사 시 조직감이 나쁘게 나타난 것으로 관찰되었다. 결론적으로 OPP필름으로 일차포장하는 것보다 산소와 수증기차단성이 높은 필름으로 이차포장할 경우 조사된 모든 품질지표가 개선되고 저장성이 향상되었으며 차단성이 높은 처리구일수록 그 효과가 높았다. 유과의 이차포장에 따라 포장비용이 증가되겠지만 제품의 품질유지기간 연장 및 반품율 저하, 그리고 소비자 만족도 제고에 따른 상품성 및 브랜드가치 향상 등 긍정적 효과를 감안하여 목적하는 저장유통기간에 부합되는 최적의 이차포장방법을 적용하는 것이 바람직할 것으로 판단된다.

가연성 액체 혼합물의 인화 위험성에 관한 연구 (A Study on Flammability Risk of Flammable Liquid Mixture)

  • 김주석;고재선
    • 한국재난정보학회 논문집
    • /
    • 제16권4호
    • /
    • pp.701-711
    • /
    • 2020
  • 연구목적: 본 연구에서는 두 물질의 혼합물(가연물+가연물)에서의 인화 위험성의 증가 또는 감소를 실험적으로 확인하고, 혼합물의 위험성을 제시하는 목적이 있기에 액체 혼합물의 인화 위험성을 실험적으로 확인하였다. 연구방법:인화점 실험방법 및 결과처리는 원유 및 석유 제품 인화점 시험 방법으로 사용되고 있는 테그밀폐식 시험방법인 KS M 2010-2008을 기준으로 실험하였다. 본 실험에 사용한 장비의 제조사는 일본의 TANAKA사에서 생산한 장비로 KS M 2010의 시험규격을 만족하는 시험장비로 인화점을 측정하였고, 점화원으로는 LP가스를, 냉각수로는 물을 사용하였다. 또한 인화점 측정시 냉각수의 온도는 약 2℃의 냉각수를 사용하여 실험을 진행하였다. 연구결과:실험결과로는 먼저 가연성+가연성 혼합물의 경우 두 물질의 인화점 차이가 크지 않으면 인화점의 변화가 거의 없었고, 두 물질의 인화점 차이가 낮으면 인화점이 높은 물질의 증가에 따라 인화점이 증가하는 경향을 보였으나, 톨루엔과 메탄올의 경우, 혼합물에서 인화점이 낮은 물질보다 더 낮은 인화점을 보였다. 또한 도료용 희석제의 경우, 혼합물로 이루어져서 그 물질의 인화점을 예상하기가 쉽지 않았지만 실험적으로 측정해 본 결과 -24℃~7℃사이로 측정되었다. 결론: 본 연구에서의 결과는 기존의 위험물안전관리법에서의 위험물 판정 기준에 대한 세부 내용의 실효성 확보 및 위험물 판정의 신뢰성 및 재현성 확보를 목적으로 인화성 혼합물에 대한 실험적 연구를 통해서 혼합물에 대한 위험성 판단 기준을 제시하였고, 향후 소방현장에서 단속되는 인화성 액체 대한 실험적 판정 기준에 대한 참고적인 자료를 제공할 수 있을 것이다. 또한 본 연구로 시험방법별 차이 실험에 대한 노하우를 축적한다면 위험물의 위험성 평가 연구에 있어 기초 자료이자 위험물 판정 관한 연구의 기반으로 활용될 수 있기를 기대한다.