• 제목/요약/키워드: Gas pass

검색결과 192건 처리시간 0.025초

GMAW 공정 중 용접 변수들이 용접 폭에 미치는 영향에 관한 연구 (The Effects of Welding Process Parameters on Weld bead Width in GMAW Processes)

  • 김일수;권욱현;박창언
    • Journal of Welding and Joining
    • /
    • 제14권4호
    • /
    • pp.33-42
    • /
    • 1996
  • In recent years there has been a significant growth in the use of the automated and/or robotic welding system, carried out as a means of improving productivity and quality, reducing product costs and removing the operator from tedious and potentially hazardous environments. One of the major difficulties with the automated and/or robotic welding process is the inherent lack of mathematical models for determination of suitable welding process parameters. Partial-penetration, single-pass bead-on-plate welds were fabricated in 12mm AS 1204 mild steel flats employing five different welding process parameters. The experimental results were used to develop three empirical equations: curvilinear; polynomial; and linear equations. The results were also employed to find the best mathematical equation under weld bend width to assist in the process control algorithms for the Gas Metal Arc Welding(GMAW) process and to correlate welding process parameters with weld bead width of bead-on-plates deposited. With the help of a standard statistical package program. SAS, multipe regression analysis was undertaken for investigating and modeling the GMAW process, and significance test techniques were applied for the interpretation of the experimental data.

  • PDF

적외선 열화상 응력측정법에 의한 동적 응력집중계수 예측 (Estimation of Dynamic Stress Concentration Factor by Infrared Thermography Stress Analysis)

  • 최만용;강기수;박정학;안병욱;김경석
    • 한국정밀공학회지
    • /
    • 제25권5호
    • /
    • pp.77-81
    • /
    • 2008
  • Structural components subjected to high frequency vibrations, such as those used in vibrating parts of gas turbine engines, are usually required to avoid resonance frequencies. Generally, the operating frequency is designed at more than resonance frequencies. When a vibrating structure starts or stops, the structure has to pass through a resonance frequency, which results in large stress concentration. This paper presents the transient thermoelastic stress analysis of vibrating cantilever beam using infrared thermography and finite element method (FEM). In FEM, stress concentration factor at the 2nd resonance vibration mode is calculated by the mode superposition method of ANSYS. In experiment, stress distributions are investigated with infrared thermography and dynamic stress concentration factor is estimated. Experimental result is agreed with FEM result within 10.6%. The advantage of this technique is a better immunity to contact problem and geometric limitation in stress analysis of small or micro structures.

고체추진제 비-정상연소의 선형 안정성해석 (A Linear Stability Analysis of Unsteady Combustion of Solid Propellants)

  • 이창진;김성인;변영환
    • 한국추진공학회지
    • /
    • 제2권1호
    • /
    • pp.59-66
    • /
    • 1998
  • 고체 추진제 연소불안정에 관한 해석은 준-정상 1차원 해석인 QSHOD(Quasi-Steady Homo-geneous One-Dimension)에 의하여 단순화된 지배방정식을 이용하여 응축영역을 해석하는 것이 일반적이다. 이때 외부교란에 대한 기체영역과 표면반응 영역의 응답은 화학반응이 발생하지 않는 고체영역의 응답에 비하여 매우 빠르므로 준-정상적인 거동을 한다. 본 연구에서는 복사열전달에 의한 열속(heat flux)이 고체 추진제의 표면에 존재하며 이 중의 일부가 고체영역으로 흡수될 때 표면에서의 선형교란을 고려한 ZN(Zeldovich-Novozhilov) 방법을 이용하여 연소불안정 현상을 이론적으로 해석하여 연소불안정 현상을 설명할 수 있는 연소 응답함수를 구하였다. 응답함수는 T-burner의 실험결과를 예측할 수 있음을 보여주었다.

  • PDF

스티커 침을 이용한 경혈지압이 척추수술 후 배변에 미치는 영향 (The Effectiveness of Meridian Acupressure Intervention Using Sticker Needles to Bowel Movement on Post Spinal Operative Patients)

  • 김양금;이향련
    • 동서간호학연구지
    • /
    • 제11권1호
    • /
    • pp.33-41
    • /
    • 2005
  • This study was conducted to identify the effect of meridian acupressure on defecation of patients with post spinal operation. The nonequivalent control group posttest only design was used. The data were obtained from 77 post spinal operative patients, 34 in the experimental 43 in control group in Y Hospital, Seoul, Korea. The neurosurgical unit A and B ward, assigned by matched sample by the name of operation such as laminectomy and posterior lumbar interbody fusion are performed. Meridian acupressure meant the method that an examiner presses response points distributed in the pass of energy vessel. In this study, meridian acupressure program was performed on as points in order of Hegue (LI-4), Zhigou (TE-6), Zusanli (S-36), Shangjuxu (S-37), Xiajuxu (S-39), Tianshu (S-25), Taichong (L-3) which was known to be related to large intestine. Data were collected from 1, July 2003 to 1, September 2003. Meridian acupressure program was carried out for 20 minutes 4 hours after operation twice daily. In order to evaluate the effect of meridian acupressure intervention, they were asked time of bowel recovery, gas passing, and defecation though questionnaire method. Data were analyzed by the SPSS/ WIN 11.0 program. The results of this study were summarized as follows; 1. Homogeneity tests of general characteristics and operation related characteristics of the experimental group and the control group were performed. General characteristics included age, sex, defecation habit, eating pattern, fluid intake, life style, activity, usage of laxative and etc. 2. Hypotheses were verification as follows; 1) Recovery of bowel sound of the experimental group who received meridian acupressure intervention was faster than that of the control group after spinal operation (t=-6.770,P=.000). 2) Time of gas passing of the experimental group who received meridian acupressure program was faster than that of the control group after spinal operation (t=-8.003, P=.000). 3) Time to defecation of the experimental group who received meridian acupressure program was faster than that of the control group after spinal operation (t=-9.026, P=.000). 4) Abdominal discomfort due to defecation of the experimental group who received meridian acupressure program was lesser than that of the control group after spinal operation (t=-3.431, P=.001). From these results, meridian acupressure intervention was effective for recovery of bowel sound, reduce time to gas passing, time to defecation and lessen abdominal discomfort due to defecation on post spinal operative patients. And therefore this intervention can probably considered on clinical practice.

  • PDF

Effects of Systemic and Focal Hypoxia on the Activities of Rostral Ventrolateral Medullary Neurons in Cats

  • Yan, Hai-Dun;Kim, Charn;Kim, Ji-Mok;Lim, Won-Il;Kim, Sang-Jeong;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • 제30권1호
    • /
    • pp.105-116
    • /
    • 1996
  • Rendering the brain ischemic would evoke the cerebral ischemic reflex which is characterized by an arterial pressor response, apnea and bradycardia. Since the rostral ventrolateral medulla (RVLM) is known to play a key role in the maintenance of normal cardiopulmonary activity, during the cerebral ischemic reflex some cardiac related cells should be excited and respiration related cells inhibited. In this context, the responses of RVLM neurons to systemie and focal hypoxia were analyzed in the present study. Twenty-five adult cats of either sex were anesthetized with ${\alpha}-chloralose$ and the single neuronal activities were identified from RVLM area. For the induction of focal hypoxia in the recording site, sodium cyanide was applied iontophoretically and for systemic hypoxia the animal was ventilated with nitrogen gas for a twenty-second period. Cellular activities were analyzed in terms of their discharge pattern and responses to the hypoxia by using post-stimulus time and single-pass time histograms. Of eighteen cardiac related cells recorded from the RVLM area, twelve cells were excited by iontophoresed sodium cyanide and of twenty-five respiration related cells, fourteen cells were excited by iontophoresed sodium cyanide. Remaining cells were either inhibited or unaffected. Eight of fifteen cells tested with iontophoresed sodium lactate were excited and remaining seven cells were inhibited. Systemic hypoxia induced by nitrogen gas inhalation elevated the arterial blood pressure, but excited, inhibited or unaffected the single neuronal activities. Some cells showed initial excitation followed by inhibition during the systemic hypoxia. Bilateral vagotomy resulted in a decrease of arterial pressor response to the systemic hypoxia, and a slight decrease in the rhythmicity related to cardiac and/or respiratory rhythms. The single neuronal responses to either systemic or focal hypoxia were not affected qualitatively by vagotomy. From the above results, it was concluded that the majority of the cardiac- and respiration- related neurons in the rostral ventrolateral medulla be excited by hypoxia, not through the mediation of peripheral chemoreceptors, and along with the remaining inhibited cells, all these cells be involved in the mediation of cerebral ischemic reflex.

  • PDF

혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구 (An Experimental Study of The J-T Cryocooler with Mixed Refrigerant)

  • 이경수;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

플라즈마발생기의 이온분율 측정 장치 설계 및 제작 (The design and fabricationt for ion fraction measurement of plasma generator)

  • 이찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

하나로 수조 방사선 준위의 저감 특성 (Reduction Characteristics of Pool Top Radiation Level in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.49-54
    • /
    • 2002
  • HANARO, 30 MW of research reactor, was installed at the depth of 13m in an open pool. The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the cote. The rest, $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to prevent the radiated gas from being lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection, and increased the radiation lovel on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2 m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated at a higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated by Visual Basic Program. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss increased. And it was verified that the radiation level above was reduced mote safely by increasing the capacity of heater.

하나로 수조 방사선 준위의 저감 특성 (Reduction Characteristics of Pool Top Radiation Level in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.221-226
    • /
    • 2001
  • HANARO, 30MW of research reactor, was installed at the depth of 13m of open pool, The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the core. The rest $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to protect that the radiated gas was lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection and increased the radiation level on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated with higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss was increased. And it was verified that the radiation level above was reduced more safely by increasing the capacity of heater.

  • PDF

5% 황산용액에서 배기밸브 보수 용접부의 부식 특성에 미치는 용접방법과 용접봉의 영향-1 (Effect of Welding method and Welding Material to Corrosion Property of Repair Weld Zone for Exhaust Valve in 5% H2SO4 Solution -1)

  • 김진경;조황래;이명훈;김윤해;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.744-752
    • /
    • 2007
  • Recently a fuel oil of the diesel engine in the ship is being changed with low quality as the oil price is higher more and more. Therefore the wear and corrosion in all parts of the engine like cylinder liner ring groove of piston crown, spindle and seat ring of exhaust valve are increased with using of heavy oil of low quality In particular the degree of wear and corrosion in between valve spindle and seat ring are more serious compared to the other parts of the engine due to operating in severe environment such as the high temperature of exhaust gas and repeating impact. Thus the repair weld to the valve spindle and seat ring is a unique method to prolong the life of the exhaust valve in an economical point of view In this study. corrosion property of both weld metal zone and base metal was investigated with some electrochemical methods such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram and polarization resistance etc. in 5% $H_2SO_4$ solution. in the case of being welded with some welding methods and welding materials to the exhaust valve specimen as the base metal. In all cases. the values of hardness of the weld metal zone were more high than that of the base metal. And their corrosion resistance were also superior to the base metal. The weld metal of A2F(AC SMAW: 2 pass welding with foreign electrode) showed a relatively good results to the corrosion resistance as well as the hardness compared to the ether welding methods and welding materials. Moreover it indicated that hardness of the weld metal by the domestic electrode was considerably high compared to that of the foreign electrode.