• Title/Summary/Keyword: Gas loop

Search Result 232, Processing Time 0.024 seconds

Dynamic Behavior of an Internal Loop Reactor during Scale-up (내부순환반응기의 Scale-up에 따른 동력학적 특성의 변화)

  • 최윤찬;박영식
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.25-31
    • /
    • 1997
  • The variations of gas hold-up, overall volumetric oxygen mass transfer coefficients and liquid circulation velocity in an internal loop reactor were investigated to manifest scale-up effect. The relationship between superficial gas velocity and gas hold-up were found as Ugr = 0.045 $\varepsilon$r in the pilot-scale and Ugr = 0.056 $\varepsilon$r in the bench-scale reactor. The overall volumetric oxygen mass tractsfer coefficient, KLa was slightly increased in the pilot-scale than in the bench-scale reactor. Flow regime was changed from the bubble flow to the churn-turbulent flow when the superficial gas velocity reached to 3.5 - 4 cm/sec in the pilot-scale.

  • PDF

Study on the Characteristics of Turbopump+Gas generator Closed-loop coupled test (터보펌프+가스발생기 폐회로 연계시험 특성 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.38-41
    • /
    • 2009
  • For the technology development of LOx/kerosene liquid rocket engine, turbopump-gas generator closed-loop coupled tests using 30tonf main engine components such as turbopump and gas generator except combustion chamber are performed. In the engine system operation environment, simulating combustion chamber by flow control units, the chill-down procedure, startup characteristics, nominal operability and smooth shutdown of turbopump+gas generator closed-loop coupled Test Plant are successfully confirmed. The serviceability of the turbopump and gas generator are evaluated. The feed-back control system for the turbopump rotational speed and gas generator mixture ratio are also verified. The results of closed-loop coupled test will be used as the technology development for the liquid rocket engine.

  • PDF

Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Open Loop Test (터보펌프 조립체-가스발생기 연계 개회로 시험에서의 시동특성 분석)

  • Moon, Yoon-Wan;Kim, Seung-Han;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.15-18
    • /
    • 2008
  • This study fulfilled analysis of startup characteristics of Turbo pump unit-Gas generator open loop test from the viewpoint of simulation. The test results were investigated and the calculated results were compared to test results. The curve for RPM developing predicted by simulation agreed well with test result. The slope of transient combustion pressure of gas generator correspond with test result.

  • PDF

Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Closed Loop Test (터보펌프 조립체-가스발생기 연계 폐회로 시험에서의 시동특성 분석)

  • Moon, Yoon-Wan;Kim, Seung-Han;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.19-22
    • /
    • 2008
  • This study fulfilled analysis of startup characteristics of Turbo pump unit-Gas generator closed loop test from the viewpoint of simulation. The test results were investigated and the calculated results were compared to test results. The curve for RPM developing predicted by simulation agreed well with test result. The slope of transient combustion pressure of gas generator correspond with test result.

  • PDF

High-Temperature Structural Analysis on the Medium-Scale PHE Prototype under the Test Condition of Small-Scale Gas Loop (소형가스루프 시험조건에서 중형 공정열교환기 시제품의 고온구조해석)

  • Song, Kee-nam;Hong, S-D;Park, H-Y
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.1
    • /
    • pp.33-38
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to a chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute has established a small-scale gas loop for the performance test on VHTR components and recently has manufactured a medium-scale PHE prototype made of Hastelloy-X. A performance test on the PHE prototype is scheduled in the gas loop. In this study, high-temperature structural analysis modeling, and macroscopic thermal and structural analysis of the medium-scale PHE prototype by imposing the established displacement boundary constraints in the previous research were carried out under the gas loop test condition. The results obtained in this study will be compared with performance test results.

Design of Rankine Steam Cycle and Performance Evaluation of HT Boiler for Engine Waste Heat Recovery (엔진 폐열 회수를 위한 랭킨 스팀 사이클 설계 및 HT Boiler의 성능 평가)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Lee, Dong-Hyuk;Lee, Heon-Kyun;Kim, Tae-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.21-29
    • /
    • 2012
  • A dual loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop (HT loop) only recovers the heat of the exhaust gas. A low temperature loop (LT loop) recovers the residual heat from the HT loop, the coolant heat and the remaining exhaust gas heat. The two separate loops are coupled with a heat exchanger. This paper has dealt with a layout of the dual loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the HT boiler, a core part of a HT loop, have been presented. The prototype of the HT boiler was evaluated by experiment. For the performance evaluation of the HT boiler, inlet temperature of the HT boiler working fluid was set equal to the temperature degree of sub-cool of $5^{\circ}C$ at the condensing pressure. The exit condition was the degree of super-heat set at $5^{\circ}C$. The characteristics of the HT boiler such as heat recovery and pressure drops of fluids were evaluated with varying flow rates and inlet temperatures of exhaust gas under various evaporating pressure conditions.

Gas turbine Control using Neural-Network 2-DOF PID Controller

  • Kim, Dong-Hwa
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.03a
    • /
    • pp.61-66
    • /
    • 1998
  • Since a gas turbine is made use of generating electricity for peak time, it is a very important to operate a peak time load with safety. The main components of a gas turbine are the compressor, the combustion chamber and the turbine. So, there also must be modeled a component of gas turbines for the control with safety but it is not easy. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply Neural-Network 2-DOF PID controler to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

High-Temperature Structural Analysis Model of the Process Heat Exchanger for Helium Gas Loop (II) (헬륨가스루프 시험용 공정열교환기에 대한 고온구조해석 모델링(II))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Seong-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1455-1462
    • /
    • 2010
  • PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the helium gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the hightemperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the helium gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype.

A Study on the Automatic Synthesis of Signed Directed Graph Using Knowledge-based Approach and Loop Verification (지식 기반 접근법과 Loop 검증을 이용한 부호운향그래프 자동합성에 관한 연구)

  • Lee Sung-gun;An Dae-Myung;Hwang Kyu Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 1998
  • By knowledge-based approach, the SDG(Signed Directed Graph) is automatically synthesized, which is commonly used to represent the causal effects between process variables. Automatic synthesis of SDG is progressed by two steps : (1)inference step uses knowledge base and (2)verification step uses Loop-Verifier. First, Topology and Knowledge Base are constructed by using the information on equipment. And then, Primary-SDG is synthesized by Character Pattern Matching between Variable-Relation-Representation generated by using Topology and Variable-Tendency-Data contained in Knowledge Base. Finally, a modified SDG is made after the Primary-SDG is verified by Loop-Verifier.

  • PDF

Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region (초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.