• 제목/요약/키워드: Gas flowmeter

검색결과 39건 처리시간 0.025초

차압을 이용한 터빈유량계 성능 진단 (Diagnosis on performance of turbine flowmeter using differential pressure in the meter)

  • 하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

적응 필터를 이용한 공동진동주파수 추정에 의한 기체 유량측정 (Estimation of Cavity Vibration Frequency Using Adaptive Filters for Gas Flow Measurement)

  • 남현도
    • 조명전기설비학회논문지
    • /
    • 제17권5호
    • /
    • pp.134-140
    • /
    • 2003
  • 본 논문에서는 공동진동현상을 이용해서 보수비 및 생산 원가를 절감 할 수 있는 기체 유량 측정 기법을 개발하고, 잡음이 있는 환경에서 공동진동주파수를 추정하여 유속 및 유량을 측정하는 기법을 제안하였다. 공동진동주파수를 이용한 기체 유량계인 cavity flowmeter는 기체가 흐르는 관에 설치된 공동으로부터 고유의 진동음을 발생시킨 후 마이크로폰을 이용하여 그 음을 측정한다. 측정된 신호는 적응필터를 이용하여 잡음을 제거한 후 공동진동주파수를 추정하며 이를 이용하여 유속 및 유량으로 계산된다. 여러 가지 측정 변수를 고려하여 계산된 유량의 정확성을 분석하기 위하여 표준 유량계와 제작된 기체 유량 측정 장치를 주파수에 따라 비교 분석하였다. 주위의 잡음이 있을 경우 공동진동주파수 추정에 영향을 받을 수 있음을 고려하여 잡음을 효과적으로 제거할 수 있는 방법으로 NLMS 알고리즘을 적용한 적응 필터를 TMS320C32를 이용하여 구현하였다. 실제 제작된 기체유량 계측 시스템을 이용하여 실험한 결과 표준 유량계와 다소 오차를 보였으나 공동진동 주파수와 유량값 사이의 선형성을 확인할 수 있었다. 공동의 크기나 모양 등을 개선하면 더욱 정확한 결과를 얻을 수 있으리라 기대된다.

수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구 (A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station)

  • 이화영;장현우;이민경;김정환;이재훈
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.30-36
    • /
    • 2022
  • 수소 충전소를 이용한 에너지원의 상거래에 있어 부정확한 계량에 의한 과 충전 등의 사고 예방과 정확한 계량을 통한 수소 상거래의 투명성 확보를 위해서는 높은 정확도의 유량계가 필요하다. 본 연구에서는 코리올리 방식 유량계 시작품을 개발하였으며, 계량 성능 검증을 위하여 기존에 운영 중인 충전소를 대상으로 공정변경을 통한 계량 성능 비교 실험 중 발생할 수 있는 사고의 예방을 위하여 위험성 평가를 수행하였다. 실증실험용 계량설비 설치를 위한 공정 변경 구간을 정의하고 HAZOP을 실시하였다. 또한 실증 실험 중 밸브오 개방 예방 등 실험자 안전성 확보를 위한 JSA도 병행하였다. HAZOP을 통하여 도출된 위험 요소를 개선하기 위한 방안을 수립하였으며 JSA를 통해 인적오류를 최소화하고 작업자의 안전성 확보할 수 있는 작업 절차를 수립하였다. 이와 같은 위험성 평가 결과를 반영하여 계량시스템 설치를 위한 설계 변경 및 시스템 제작을 완료하였으며 개발된 계량기 시작품의 성능비교 실험을 통해 안전성을 확인할 수 있었다. 개발된 시작품 유량계는 70MPa의 운전 조건에서 총 30회 유량 측정 실험 결과 평균 오차는 -1.58% ~ 3.96%로 나타났다. 이와 같은 계량오차는 상업용으로 설치 운영 중인 유량계와 동등 수준의 성능을 가진 것으로 분석되었다.

MCFC용 Steam Reformer 개질성능 분석 및 운전평가 (The Performance & Operation Analysis of a Steam Reformer for MCFC)

  • 서혜경;고준호;임희천
    • 한국수소및신에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.149-159
    • /
    • 2000
  • This paper is concerned with the performence of a steam reformer for 25kW class MCFC, which is compared with the theoretically calculated results at various operating conditions. The theoretical $H_2$ production amount and $CH_4$ conversion rate are calculated with variations of temperature and steam/carbon (S/C) ratio using fortran program, and the actual values are measured from flowmeter and gas chromatography. As a result of the comparison of theoretical and actual values, the theoretical $H_2$ production amount is calculated by $24.4m^3/hr$ at the normal operating condition(LNG $9m^3/hr$, S/C ratio 5, absolute pressure $2.77kg/cm^2$, $610^{\circ}C$), but the actual production amount is only $19.4m^3/hr$, which is 79.5% of the theoretical value. Nevertheless, at the normal operating condition, the reformer for 25kW class MCFC performed well for a 2,100 hr long run operation, constantly producing $H_2$.

  • PDF

내경 1.77 mm관내 R-22와 R-410A의 응축열전달 (The Condensation Heat Transfer of R-22 and R-410A in an Inner Diameter Tube of 1.77 mm)

  • 손창효;노건상
    • 한국가스학회지
    • /
    • 제12권1호
    • /
    • pp.48-53
    • /
    • 2008
  • 본 연구는 세관내 R-22와 R-410A의 응축 열전달 계수를 실험적으로 조사하였다. 냉매 순환루프의 주요 구성품은 수액기, 변속 액펌프, 질량유량계, 증발기(예열기), 응축기(시험부)로 구성된다. 시험부는 평활, 수평 동관으로 내관의 내경과 외경이 각각 1.77 mm와 3.38 mm이다. 냉매 질량유속은 $450{\sim}1050\;kg/(m^2s)$이고, 입출구 평균건도는 $0.05{\sim}0.095$이다. 주요 실험결과를 요약하면, 응축 열전달 계수는 질량유속과 건도이 증가할수록 증가하였고, R-410A의 응축 열전달 계수가 R-22에 비해 약간 높았다. 종래의 상관식과 비교한 결과, 저건도와 저질량유속을 제외하고는 실험값과 종래의 상관식으로 예측한 값의 차이가 큰 것으로 나타났다.

  • PDF

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.

급성산-염기 균형장해때의 국소 혈류량 변화 (Local blood flow in acute respiratory and metabolic acid-base distrubances in dog)

  • 김삼현;이영균;김우겸
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.101-109
    • /
    • 1984
  • The influences of acute respiratory and metabolic acid-base disturbances on the carotid, renal and coronary blood flow were measured in dogs. Respiratory acidosis was induced by artificial respiration with 8% CO2 -02 gas mixture and respiratory alkalosis was induced by hyperventilation under the control of respirator. Metabolic acidosis and metabolic alkalosis were induced by intravenous infusion of 0.3N hydrochloric acid and 0.6M sodium bicarbonate solution. To observe the effect of hyperkalemia, isotonic potassium chloride solution was infused. CVI electromagnetic flowmeter probes were placed on the left common carotid artery, left renal artery and left circumflex coronary artery. Each flow was recorded on polygraph. 1. The carotid blood flow showed rapid showed rapid and marked increase in acute respiratory acidosis. Even in the cases when arterial blood pressure was lowered during the state of respiratory acidosis, carotid blood flow increased. By the infusion of hydrochloric acid, carotid blood flow increased slowly and returned to the previous label after discontinuation of the infusion. Carotid blood flow also increased by the infusion of large amount of sodium bicarbonate, but it might be the combined effect of expansion of extracellular fluid and compensatory elevation of carbon dioxide tension. 2.The renal blood flow remained unchanged during the acute acid-base disturbances, suggesting effective autoregulation. Renal blood flow, however, increased very slowly when the infusion of potassium chloride continued for a long period. 3.Although less marked than the carotid blood flow, the coronary blood flow increased in the acute respiratory and metabolic acidosis. In asphyxiated condition, coronary blood flow increased most markedly and this might be the combined effect of hypoxia, hypercapnea, and lowering of pH. In summary, the carotid blowflow showed more marked change in the acute respiratory and metabolic acidosis than the renal and coronary blood flow. Respiratory and metabolic components of acid-base disturbances may influence the local blood flow concomitantly, there being more differences in the individual responses, but respiratory component manifested more rapid and marked effect than metabolic component.

  • PDF

단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가 (A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents)

  • 황성민;김기웅;강찬석;이성주;이용호
    • Progress in Superconductivity
    • /
    • 제13권2호
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.

투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정 (The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter)

  • 김진섭;김종범;김재호;이나영;정성희
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.13-20
    • /
    • 2008
  • 석유 및 정유관련 산업에서 다중상(multi-phase flow) 유체의 배관 내 흐름은 일반적인 현상의 하나이다. 그러나 각각의 상에 대한 정확한 유량측정은 항상 정확한 결과획득을 얻는데 장애의 근원으로 작용하였다. 일반 상업용 유량계는 일정 이상의 기포가 포함된 유체 흐름의 경우 유량계측에 상당한 오차를 유발한다. 본 연구에서는 ${\gamma}$-ray attenuation 기법을 이용하여 clamp-on 타입으로 배관 외부에서 다중상 유체흐름의 유량 측정을 수행하였다. 사용된 밀봉 감마선원으로는 $^{137}Cs$ 20 mCi와 17 mCi 두 개의 동위원소를 사용하였으며, 감마선 검출기로는 $2"{\times}2"$ NaI(Tl) 섬광계수관을 이용하였다. 방사선 검출기로부터 데이터를 수집하고 각각의 데이터에 대해 푸리에 변환과 필터링을 통해 노이즈를 최소화하였다. 복원된 신호에 대해 상호상관함수(cross correlation function)를 적용하여 두 검출기 사이의 통과시간(transit time)을 측정함으로써 유량을 산정하였다. 배관 내 기포함량 측정을 통해 유량을 보정해줌으로써 측정유량의 정확도를 높였다. 두 선원간의 거리가 4D(D; inner diameter) 그리고 본 실험의 측정조건(N/S: $0.12{\sim}0.15$, sampling time ${\Delta}\;t$: 4msec) 하에서 기포량(단면적 대비 $6.1\;%{\sim}9.2\;%$) 보정을 통해 산정된 유량은 계측오차가 실제 평균유량 대비 1.7 % 이하인 정확도를 보였다. 또한 두 밀봉 감마선원 간의 거리가 가까울수록 통과시간 측정에 정확도가 향상되므로 보다 정확한 유량측정이 가능하였다. 본 연구를 통해 다중상 혼합유체의 유량을 밀봉감마선원과 상호상관 기법으로 이용하여 계측할 수 있음을 확인하였다. 방사성동위원소의 선택 및 계측시스템의 최적화 조건 등에 대한 추가연구가 수행된다면 석유화학 산업과 같은 장치산업의 유지관리 측면에 경제적으로 크게 기여할 수 있을 것으로 판단된다.