• Title/Summary/Keyword: Gas conduction

Search Result 203, Processing Time 0.021 seconds

A Study on The Effects of AC Corrosion on Underground Gas Pipeline Running Parallel with High Power Cables (Case II) (편력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구(II))

  • Bae, Jeong-Hyo;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.74-79
    • /
    • 2002
  • We have been analyzed the interference problems already in steady state, especially AC corrosion when the gas pipeline is burred with power cable in the same submarine tunnel. In the next stage, we analyze the induced voltage in a fault condition of 154[kV] underground T/L. This paper presents the results of them which are limitation of safety voltage. meodeling of power cables, gas pipeline and grounding systems, analysis of induced voltage in a fault condition, and protection of Power line system.

Proton Conduction in Y2O3-doped SrZrO3 (Y2O3가 도핑된 SrZrO3에서의 프로톤전도도)

  • 백현덕
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.7
    • /
    • pp.635-641
    • /
    • 2002
  • Electrical conduction of $SrZrO_3$ doped with $Y_2O_3$ was measured as a function of gas atmosphere and temperature by impedance spectroscopy. Hydrogen dissolution, due to an enhanced driving force in the presence of oxygen, results in protonation by water incorporation. Proton conductivity increased with water vapor pressure, ${P_w}^{1/2}$. In the pure hydrogen atmosphere, the dissolution of hydrogen,$H_2(g)=2H_{i}$ +2e', is supposed to be driven by a reduced activity of electrons, ascribable to their trapping in oxygen vacancies. The activation energy of electrical conductivity was 50 kJ/mol, in wet argon atmosphere in the temperature range of $600~900^{\circ}C$, similar to those reported for proton conduction in the literature. Grain boundary effect in proton conduction was substantial in the 10% doped case at temperatures lower than $700^{\circ}C$.

Ozone Generation Characteristics in Dielectric Barrier Discharge (유전체 장벽 방전내에서 오존발생 특성)

  • Lee, Hyeong-Ho;Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.673-678
    • /
    • 2000
  • The dielectric barrier discharge(DBD) is a common method to create a nonthermal plasma in which electrical energy is used to create electrons with a high average kinetic energy. The unique aspect of dielectric barrier discharges is the large array of short lifetime(10ns) silent discharges created over the surface of the dielectric. A silent discharge is generated when the applied voltage exceeds the breakdown voltage of the carrier gas creating a conduction path between the applied electrode and grounded electrode. As charge accumulates on the dielectric, the electric field is reduced below the breakdown field of the carrier gas and the silent discharge self terminates preventing the DBD cell from producing a thermal arc. In fact, the most significant application of dielectric barrier discharges is to generate ozone for contaminated water treatment. Therefore, experiments were perfomed at 1∼2[bar] pressure using a coaxial geometry single dielectric barrier discharge for ozone concentrations and energy densities. The main result show that the concentration and efficiency of ozone are influenced by gas nature, gas quantity, gas pressure, supplied voltage and frequency.

  • PDF

Electrical Resistivity Monitoring of Gas Hydrate Formation (가스하이드레이트 형성 과정의 비저항 모니터링)

  • Lee, J.Y.;Lee, J.H.;Lee, D.S.;Lee, W.S.;Kim, S.J.;Huh, D.G.;Kim, H.T.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.186-187
    • /
    • 2008
  • Electrical resistivity in hydrate-bearing sediments is sensitive to porosity, gas hydrate saturation, gas content, pore fluid composition, and temperature, so electrical measurements such as well logs and electromagnetic surveys have been used to explore gas hydrate-bearing formation. The high pressure tomography cell is designed considering the effect of electrode configuration and electrical shielding on tomography measurements and the safety. The evolution of electrical conductivity during $CO_2$ hydrate formation and dissociation reflects the combined effects of concurrent changes that include ionization of dissolved $CO_2$, temperature-dependent ionic mobility, changes in the degree of saturation, ion exclusion, surface conduction, and porosity changes. Measurements during hydrate formation and dissociation require careful analysis to properly interpret signatures, in particular when out-of plane conductivity anomalies prevail.

  • PDF

DEVELOPMENT OF MARS-GCR/V1 FOR THERMAL-HYDRAULIC SAFETY ANALYSIS OF GAS-COOLED REACTOR SYSTEMS

  • LEE WON-JAE;JEONG JAR-JUN;LEE SEUNG-WOOK;CHANG JONGHWA
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.587-594
    • /
    • 2005
  • In an effort to develop a thermal-hydraulic (TH) safety analysis code for Gas-cooled Reactors (GCRs), the MARS code, which was primarily developed for TH analysis of water reactor systems, has been extended here for application to GCRs. The modeling requirements of the system code were derived from a review of major processes and phenomena that are expected to occur during normal and accident conditions of GCRs. Models fur code improvement were then identified through a review of existing MARS code capability. Among these, the following priority models necessary fur the analysis of limiting high and low pressure conduction cooling events were evaluated and incorporated in MARS-GCR/V1 : 1) Helium (He) and Carbon Dioxide ($CO_2$) as main system fluids, 2) gas convection heat transfer, 3) radiation heat transfer, and 4) contact heat transfer models. Each model has been assessed using various conceptual problems for code-to-code benchmarks and it was demonstrated that MARS-GCR/V1 is capable of capturing the relevant phenomena. This paper describes the models implemented in MARS-GCR/V1 and their verification and validation results.

Electromagnetic Characteristics of MHD Machine (MHD 기기의 전자기적 특성 고찰)

  • Jang, S.M.;Kim, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.266-268
    • /
    • 1998
  • The linear MHD(magnetohydro-dynamic) machine obtains the linear motion by replacing the solid conducting secondary of LIM with the ionized gas, plasma or the liquid metal. The electromagnetic pump which is a kind of MHD machine is divided into induction pump and conduction pump. This paper shows the classification and development trends of MHD machines and the characteristics of double sided flat linear induction pump (DFLIP).

  • PDF

DEVELOPMENT OF A CORE THERMO-FLUID ANALYSIS CODE FOR PRISMATIC GAS COOLED REACTORS

  • Tak, Nam-Il;Lee, Sung Nam;Kim, Min-Hwan;Lim, Hong Sik;Noh, Jae Man
    • Nuclear Engineering and Technology
    • /
    • v.46 no.5
    • /
    • pp.641-654
    • /
    • 2014
  • A new computer code, named CORONA (Core Reliable Optimization and thermo-fluid Network Analysis), was developed for the core thermo-fluid analysis of a prismatic gas cooled reactor. The CORONA code is targeted for whole-core thermo-fluid analysis of a prismatic gas cooled reactor, with fast computation and reasonable accuracy. In order to achieve this target, the development of CORONA focused on (1) an efficient numerical method, (2) efficient grid generation, and (3) parallel computation. The key idea for the efficient numerical method of CORONA is to solve a three-dimensional solid heat conduction equation combined with one-dimensional fluid flow network equations. The typical difficulties in generating computational grids for a whole core analysis were overcome by using a basic unit cell concept. A fast calculation was finally achieved by a block-wise parallel computation method. The objective of the present paper is to summarize the motivation and strategy, numerical approaches, verification and validation, parallel computation, and perspective of the CORONA code.

NITROGEN DOPED DIAMOND LIKE CARBON FILM SYNTHESIZED BY MICROWAVE PLASMA CVD

  • Urao, Ryoichi;Hayatsu, Osamu;Satoh, Toshihiro;Yokota, Hitoshi
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.549-555
    • /
    • 1996
  • Diamond Like Carbon film is amorphous film which is considered to consist of three coordinate graphite structure and tetrahedron coordinate diamond structure. Its hardness, thermal conductivity and chemical stability are nearly to one of diamond. It is well known to become semi-conductor by doping of inpurity. In this study Diamond Like Carbon film was synthesized by Microwave Plasma CVD in the gas mixture of hydrogen-methan-nitrogen and doped of nitrogen on the single-crystal silicon or silica glass. The temperature of substrate and nitrogen concentration in the gas mixture had an effect on the bonding state, structural properties and conduction mechanism. The surface morphology was observed by Scanning Electron Microscope. The strucure was analyzed by laser Raman spectrometry. The bonding state was evaluated by electron spectroscopy. Diamond Like Carbon film synthesized was amorphous carbon containing the $sp^2$ and $sp^3$ carbon cluster. The number of $sp^2$ bonding increased as nitrogen concentration increased from 0 to 40 vol% in the feed gas at 1233K substrate temperature and at $7.4\times10^3$ Pa. Increase of nitrogen concentration made Diamond Like Carbon to be amorphous and the doze of nitragen could be controlled by nitrogen concentration of feed gas.

  • PDF

CHANDRA SPECTROSCOPY OF SUPERNOVA REMNANT 3C 391

  • CHEN YANG;SU YANG;SLANE PATRICK O.;WANG Q. DANIEL
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.211-214
    • /
    • 2005
  • We performed a spatially resolved spectroscopic study of the thermal composite supernova remnant 3C 391 by the Chandra observation. Broad- and narrow-band X-ray images show a southeast-northwest elongated morphology and unveil a highly clumpy structure of the remnant. The spectral analysis for. the small-scale features indicates normal metal abundance and uniform temperature for the interior gas. The properties of the hot gas are largely in agreement with the cloudlet evaporation model as a main mechanism for the 'thermal composite' X-ray appearance, though radiative rim and thermal conduction may also be effective. An unresolved X-ray source, with a power-law spectrum, is observed on the northwest border. The equivalent width images reveal a faint finger-like protrusion in Si and S lines out of the southwest radio border.

An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas (헬륨을 이용한 열유속센서 검정방법의 실험적 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF