The Effect of Temperature on the Breakthrough of Charcoal Tube During Vinyl Chloride Monomer Sampling (공기중 염화비닐단량체 포집시 온도가 파과현상에 미치는 영향)

  • Park, Youn Jung;Lee, Sang Hoi;Kim, Chi Nyon;Won, Jong Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.115-123
    • /
    • 1998
  • Vinyl chloride monomer exists as gas phase at normal temperature and reacts with oxygen and strong oxidant in the air to form oxidized materials. Because of being easily synthesized, it is used as a main source at the synthetic reaction process of PVC synthesis factories. Ministry of Labor regulates its usage as a carcinogen and its exposure level as 1 ppm. But the amount of VCM production in PVC and VCM production process hasn't been exactly estimated. In addition, facilities of this factory are located in outdoor. Therefore, this study was designed to investigate effects of temperature on breakthrough of charcoal tube at a fixed concentration and temperature during VCM sampling based on NIOSH and OSHA methods which were used as methods of occupational environment measuring and analysis. During the sampling of VCM, methods of OSHA and NIOSH require flow rate of 0.05 lpm and sampling volume of $3{\ell}$, $5{\ell}$ respectively, at this time carbon molecular sieve tube and coconut shell charcoal tube are used to observe the breakthrough along with concentration and temperature. As a result, significant difference between average adsorbed amounts of OSHA methods but that of NIOSH methods cannot be found. NIOSH method is likely to be effected by high temperature and normal temperature in high concentration. Breakthrough is not found in the method of OSHA at different conditions of temperature and concentration. As the result of this study we could verify that breakthrough occurred in the process of sampling VCM with NIOSH methods. Therefor in summer time, breakthrough should be considered and research on the breakthrough volume should be done. It is considered the research about the specificity of the coconut shell charcoal and carbon molecular sieve sorbent should be done when sampling VCM in comming days.

  • PDF

Desulfurization of Sulfur Compounds in City-gas using Metal Salt Impregnated Zeolite (금속이온이 담지 된 제올라이트를 이용한 도시가스 내 부취제 제거)

  • Song, Hirn-Ill;Ko, Chang Hyun;Kim, Jae Chang;Kim, Jong-Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.143-148
    • /
    • 2007
  • In hydrogen production for fuel cell by reforming city-gas, sulfur compounds, odorant in city-gas, are detrimental to reforming catalyst and fuel cell electrodes. We prepared metal salt impregnated ${\beta}-zeolite(BEA)$ to remove sulfur compound in city-gas by adsorption. The sulfur breakthrough adsorption capacity was changed depending on the concentration and species of metal salt. $AgNO_3$ impregnated BEA showed the highest sulfur breakthrough capacity among adsorbents used in this experiment(41.1 mg/g). But metal salt impregnated BEA such as $Ni(NO_3)_2/BEA$, $Fe(NO_3_)_3/BEA$, $Co(NO_3)_2/BEA$ showed a certain amount of sulfur adsorption capacity comparable to $AgNO_3/BEA$. Adsorption temperature effect, desorption study, and x-ray photoelectron spectroscopy analysis revealed that the dominant interaction between metal impregnated adsorbent and sulfur compounds was not chemisorption but physisorption.

Adsorption Characteristics of Acetone, Benzene, and Metylmercaptan in the Fixed Bed Reactor Packed with Activated Carbon Prepared from Waste Citrus Peel (폐감귤박으로 제조한 활성탄을 충전한 고정층 반응기에서 아세톤, 벤젠 및 메틸메르캅탄의 흡착특성)

  • Kam, Sang-Kyu;Kang, Kyung-Ho;Lee, Min-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.28-36
    • /
    • 2018
  • Adsorption experiments of three target gases such as acetone, benzene, and methyl mercaptan (MM) were carried in a continuous reactor using the activated carbon prepared from waste citrus peel. In a single gas system, the breakthrough time obtained from using the activated carbon (WCAC) prepared from waste citrus peel. In a single gas system, the breakthrough time obtained from the breakthrough curve decreased with increasing the inlet concentration and flow rate, but increased with respect to the aspect ratio (L/D). Adsorbed amounts of the target gases by WCAC increased as a function of the inlet concentration and aspect ratio. However, adsorbed amounts with the increase of the flow rate were different depending upon target gases. Results from the breakthrough time and adsorbed amount showed that the affinity for WCAC was the highest in benzene, followed by acetone and then MM. On the other hand, in the binary and ternary systems, the breakthrough curve showed a roll-up phenomenon where the adsorbate having a small affinity for WCAC was replaced with the adsorbate with a high affinity. The adsorption of acetone on WCAC was more strongly affected when mixing with the nonpolar benzene than that of using sulfur compound MM.

Measurement of mass Transfer Coefficients for Adsorptive Bulk Gas Separation with Velocity Variations (기체속도가 변하는 벌크기체의 흡착공정에서 물질전달계수의 측정)

  • Min, Jun-Ho;Choi, Min-Ho;Suh, Sung-Sup
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.310-318
    • /
    • 1999
  • The concentration breakthrough curves were examined to predict mass transfer coefficients of nitrogen and oxygen in adsorption column for design data of PSA process. Experimental breakthrough curves for bulk gas flow were compared with theoretical simulation results. For quantitative analysis of the adsorption, coupled Langmuir isotherm was considered and LDF model was used to describe the mass transfer effect. In the experimental and theoretical results, it was found that mass transfer coefficient was not affected by flow rate but strongly affected by pressure. As a result of this tendency, mass transfer resistance in this system was proved to belong to the macropore diffusion controlling region and the mass transfer coefficients could be expressed by exponential functions of pressure change. The mass transfer coefficients for one component, nitrogen or oxygen, were successfully applied to breakthrough curves for bulk mixed gases. The experimental curves were reasonably in consistent with the theoretical curves and the error time was less than 5 percent.

  • PDF

Development of feasible program of exchange period for chemical cartridge in the workplace (II) - Method of using odor threshold (작업장에서 사용 가능한 방독마스크 정화통 교체주기 프로그램의 개발(II) - 냄새 서한도(odor threshold)를 이용하는 방법)

  • Han, Don-Hee;Kang, Min-Sun;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2009
  • The greatest concern of vapor/gas respirators is when to exchange chemical cartridges, but it is very difficult to estimate the breakthrough time of them in the workplace spot due to so many factors influencing on breakthrough. There needs to study on estimating cartridge exchange period available practically in the spot, even if it is not precise. In the previous study, authors suggested the method on estimating service-life of chemical cartridges using cartridges discarded after use. This followed study was to estimate exchange period for chemical cartridges using comparison of concentrations between Korean Occupational Exposure Limits (KOELs) and odor thresholds of chemicals. Chemicals were divided into four groups, I, II, III and IV groups. Group I chemicals are relatively safe if cartridges are just or slightly delayed exchanged when smelling since odor thresholds were less than 0.5 times KOELs. Odor threshold of Group II chemicals are 0.5~2.0 times KOELs and potentially hazardous if cartridges are exchanged when smelling. Those chemicals should be conducted program on estimating service-life of cartridges, which was just previously published (J Kor Soc Occup Environ Hyg 2008;18(3) 204-215). Group III chemicals (odor thresholds are more than 2.0 times KOELs) and Group IV chemicals (odorless or no data for smelling) must be performed the above mentioned program before cartridges. Even if this method on cartridge exchange using odor threshold is practically widely used in the workplace spot in the present, program on estimating service-life of cartridges is recommended for all chemicals to reduce potentially hazards.

Study on Accuracy and Validity Tests for Various Prediction Models for Gas and Vapor Respirator Cartridge Service Lives (가스 및 유기용제용 호흡보호구의 정화통에 대한 수명예측방법의 정확도 및 타당성 검증연구)

  • Park, Doo Yong;Park, Ji Young;Yoon, Chung Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.19-31
    • /
    • 1999
  • Most breakthrough tests are conducted at higher concentration levels compared to those in the field of air-purifying respirator applications. For example, typical challenge concentrations for breakthrough tests agains tcarbon tetrachloride are ranged between 250-1000 ppm although applicable concentrations range for air-purifying cartridge is 5-50 ppm for carbon tetrachloride. However, no guarantee has been made that isotherms derived from the experiment at high challenge concentrations could estimate adsorption capacity at the lower concentration range where workers wear usually air-purifying respirators. Three models of adsorption isotherms (Freundlich, Langmuir and Dubinin/Radushkevich(D/R) isotherms) that have been commonly applied for respirator cartridge testing were evaluated. Adsorption capacity at each challenge concentration was calculated from the Reaction Kinetic equation fitted for the breakthrough data. These data were used for derivation of three isotherms. In general, the D/R isotherm has given the best agreement between estimated adsorption capacities and experimentally measured. If the challenge concentration of 100 ppm is included for derivation of models, Freundlich and D/R models could succes sfully produced good estimations for adsorption capacities at 50 ppm level. Estimated adsorption capacities by both models ranged in 94 - 109 % of the experimentally measured. However, Langmuir model gives underes timation in all cases.

  • PDF

Adsorption Characteristics of Activated Carbons According to Impregnation Concentrations and Inlet CO2 Gas Concentrations (함침농도와 CO2 가스 유입농도에 따른 활성탄의 흡착특성)

  • Lee, Dong-Hwan;Kam, Sang-Kyu;Lee, Song-Woo;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1403-1407
    • /
    • 2010
  • The adsorption characteristics of $CO_2$ gas on impregnated activated carbons with MEA (Mono-ethanolamine) and AMP (2-Amino 2-methyl 1-propanol) were studied to improve the adsorption ability of $CO_2$ gas on activated carbon. The equilibrium adsorption capacity of $CO_2$ gas was increased by increment of impregnation concentration up to 40 %, but decreased above 50 %. The adsorption capacity of activated carbon impregnated with AMP was higher than activated carbon impregnated with MEA. The breakthrough was fast according to increment of inlet concentration of $CO_2$ gas.

A Study on VOCs Adsorption Properties Using Fine-fiber (극세섬유를 이용한 VOCs흡착 특성에 관한 연구)

  • An, Hyung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.35-40
    • /
    • 2010
  • This study is to develop of an adsorbent for the removing of human body harmful benzene, toluene, and p-xylene as VOCs. Thus, this study researched the adsorption efficiency of the commercial ACF and the reactivated ACF by KOH/ACF to molar 1: 1. As the results, the effects have shown to enlarge with the increasing of VOCs concentration for adsorptive breakthrough time and breakthrough percentage on each substance. Also, the study have investigated as a similar tendency in case of desorption efficiency for toluene and p-xylene at constant concentration as 125PPM and 0.5$\ell$/min volume flow rate. But in case of benzene, it has been investigated to have rather lower desorption efficiency re-activation ACF than commercial ACF.

Gas Injection Experiment to Investigate Gas Migration in Saturated Compacted Bentonite (포화 압축 벤토나이트 내 기체 이동 현상 관측을 위한 기체 주입 시험)

  • Jung-Tae Kim;Changsoo Lee;Minhyeong Lee;Jin-Seop Kim;Sinhang Kang
    • Tunnel and Underground Space
    • /
    • v.34 no.2
    • /
    • pp.89-103
    • /
    • 2024
  • In the disposal environment, gases can be generated at the interface between canister and buffer due to various factors such as anaerobic corrosion, radiolysis, and microbial degradation. If the gas generation rate exceeds the diffusion rate, the gas within the buffer may compress, resulting in physical damage to the buffer due to the increased pore pressure. In particular, the rapid movement of gases, known as gas breakthroughs, through the dilatancy pathway formed during this process may lead to releasing radionuclide. Therefore, understanding these gas generation and movement mechanism is essential for the safety assessment of the disposal systems. In this study, an experimental apparatus for investigating gas migration within buffer was constructed based on a literature review. Subsequently, a gas injection experiment was conducted on a compacted bentonite block made of Bentonile WRK (Clariant Ltd.) powder. The results clearly demonstrated a sharp increase in stress and pressure typically observed at the onset of gas breakthrough within the buffer. Additionally, the range of stresses induced by the swelling phenomenon of the buffer, was 4.7 to 9.1 MPa. The apparent gas entry pressure was determined to be approximately 7.8 MPa. The equipment established in this study is expected to be utilized for various experiments aimed at building a database on the initial properties of buffer and the conditions during gas injection, contributing to understanding the gas migration phenomena.

Adsorption Characteristics of Toluene Vapor in Fixed-bed Activated Carbon Column (고정층 활성탄 흡착반응기에서 기상 톨루엔의 흡착특성)

  • Lim Jin-Kwan;Lee Song-Woo;Kam Sang-Kyu;Lee Dong-Whan;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • Adsorption characteristics of toluene vapor, which is one of important source of volatile organic compounds (VOCs), by activated carbon were investigated using a fixed bed adsorption column. The operating parameters such as breakthrough curve, adsorption capacity, mass transfer zone (MTZ), and length of unused bed (LUB) were studied. The experimental results showed that the breakthrough time decreased with increasing inlet toluene concentration and gas flow rate. MTZ and LUB increased with the increase of inlet concentration, gas flow rate, and particle size of activated carbon. The adsorption capacity increased with the increase of inlet toluene concentration, while it decreased with increasing particle size. However, it was kept at constant value regardless of the increase of gas flow rate. Adsorption isotherm of toluene vapor could be represented by the Freundlich adsorption equation fairly well. From the adsorption experiments using some VOC gases such as toluene, xylene, butyl acetate. butanol and acetone, it was also found that the adsorption capacity was higher in the case of gas with higher boiling point and lower vapor pressure.