Browse > Article

Development of feasible program of exchange period for chemical cartridge in the workplace (II) - Method of using odor threshold  

Han, Don-Hee (Department of Occupational Health and Safety Engineering, Inje University)
Kang, Min-Sun (Department of Occupational Health and Safety Engineering, Inje University)
Yi, Gwang Yong (Occupational Safety & Health Research Institute, KOSHA)
Publication Information
Journal of Korean Society of Occupational and Environmental Hygiene / v.19, no.2, 2009 , pp. 102-112 More about this Journal
Abstract
The greatest concern of vapor/gas respirators is when to exchange chemical cartridges, but it is very difficult to estimate the breakthrough time of them in the workplace spot due to so many factors influencing on breakthrough. There needs to study on estimating cartridge exchange period available practically in the spot, even if it is not precise. In the previous study, authors suggested the method on estimating service-life of chemical cartridges using cartridges discarded after use. This followed study was to estimate exchange period for chemical cartridges using comparison of concentrations between Korean Occupational Exposure Limits (KOELs) and odor thresholds of chemicals. Chemicals were divided into four groups, I, II, III and IV groups. Group I chemicals are relatively safe if cartridges are just or slightly delayed exchanged when smelling since odor thresholds were less than 0.5 times KOELs. Odor threshold of Group II chemicals are 0.5~2.0 times KOELs and potentially hazardous if cartridges are exchanged when smelling. Those chemicals should be conducted program on estimating service-life of cartridges, which was just previously published (J Kor Soc Occup Environ Hyg 2008;18(3) 204-215). Group III chemicals (odor thresholds are more than 2.0 times KOELs) and Group IV chemicals (odorless or no data for smelling) must be performed the above mentioned program before cartridges. Even if this method on cartridge exchange using odor threshold is practically widely used in the workplace spot in the present, program on estimating service-life of cartridges is recommended for all chemicals to reduce potentially hazards.
Keywords
Odor threshold; service-life of cartridge; breakthrough; vapor/gas respirator;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 김덕기, 신창섭. 작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측 -모사에 의한 정화통과 샘플관의 파과시간-, 한국산업안전학회지 1996;11(2): 89-95
2 정해동, 백남원. 복합유기용제에 노출된 호흡용보호구용 정화통의 파과에 관한 연구. 한국산업위생학회지 1996;6(1): c
3 한국산업안전보건연구원 . 2009년 2월 10일 접속, http://oshri.kosha.or.kr/information/info_data
4 Tanaka, S, Y Tsuda, S Kitamura, M Shimada, H Arito, Y Seki. A simple method for detecting breakthroughs in used chemical cartridges, Am. Ind. Hyg. Assoc. J. 1991;62(2): 168-171   DOI   ScienceOn
5 Yoon, YH, JH Nelson, J Lara, C Kamel, D Fregeau. A theoretical interpretation of the service life of respirator cartridges for the binary acetone/m-xylene system, Am. Ind. Hyg. Assoc. J.1991;52(2): 65-74   DOI   ScienceOn
6 Yoon, YH, JH Nelson, J Lara. Respirator cartridge service-life:Exposure to mixtures, Am. Ind. Hyg. Assoc. J. 1996;57(9):809-819   DOI   PUBMED   ScienceOn
7 Nelson, GO and CA Harder. Respirator cartridge efficiency studies:V - Effect of solvent vapor. Am. Ind. Hyg. Assoc. J.1974;35(7): 391-410   DOI   ScienceOn
8 Cohen, HJ, SP Levine, RP Garrison. Development of a field method for determination the service lives of respirator cartridges - Part IV: Results of field validation trials. Am. Ind. Hyg. Assoc. J. 1991 52(7): 263-270   DOI   ScienceOn
9 한국산업안전공단. 화학물질 노출에 의한 보호구 사용 실태 조사 및 관리방안 연구(보건분야연구자료 연구원 2008-1-2) 2008: 108-109
10 한돈희, 이진헌. 최신산업위생관리. 신광문화사 2007: 546-547
11 Rajhans, GS and BP Pathak. Practical guide to respirator usage in industry, 2nd ed., Butterworth-Heinemann, 2001
12 박두용, 박지영, 윤충식. 가스 및 유기용제용 호흡용보호구의 정화통에 대한 수명예측방법의 정확도 및 타당성 검증연구. 한국산업위생학회지 1999;9(2): 19-31
13 한돈희, 이상영. 작업장에서 사용 가능한 방독마스크 정화통교체주기 프로그램의 개발(I)-폐정화통을 이용한 파과시간예측실험. 한국산업위생학회지 2008;18(3): 204-215
14 김기환, 김덕기, 신창섭. 작업현장의 환경조건에 따른 방독 마스크 정화통의 수명예측(II). 한국산업안전학회지 1996;11(4): 72-78
15 American Industrial Hygiene Association (AIHA). Respiratory Protection Committee: Respiratory Protection -A manual and guideline-, 3rd ed., AIHA Press, Fairfax, VA 22031, 2001
16 Nelson, GO and AN Correia. Respirator cartridge efficiency studies:VII - Summary and conclusions, Am. Ind. Hyg. Assoc. J.1976);37(9): 514-525   DOI   ScienceOn