• Title/Summary/Keyword: Gas Tank

Search Result 681, Processing Time 0.024 seconds

Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State (포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석)

  • Lee, Jin-Ho;Hwang, Se-Yun;Lee, Sung-Je;Lee, Jang Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.299-308
    • /
    • 2022
  • This study was conducted to predict the tendency for heat exchange and boil-off gas (BOG) in a liquefied hydrogen tank under sloshing excitation. First, athe fluid domain excited by sloshing was modeled using a multiphase-thermal flow domain in which liquid hydrogen and hydrogen gas are in the saturated state. Both the the volume of fluid (VOF) and Eulerian-based multi-phase flow methods were applied to validate the accuracy of the pressure prediction. Second, it was indirectly shown that the fluid velocity prediction could be accurate by comparing the free surface and impact pressure from the computational fluid dynamics with those from the experimental results. Thereafter, the heat ingress from the external convective heat flux was reflected on the outer surfaces of the hydrogen tank. Eulerian-based multiphase-heat flow analysis was performed for a two-dimensional Type-C cylindrical hydrogen tank under rotational sloshing motion, and an inflation technique was applied to transform the fluid domain into a computational grid model. The heat exchange and heat flux in the hydrogen liquid-gas mixture were calculated throughout the analysis,, whereas the mass transfer and vaporization models were excluded to account for the pure heat exchange between the liquid and gas in the saturated state. In addition, forced convective heat transfer by sloshing on the inner wall of the tank was not reflected so that the heat exchange in the multiphase flow of liquid and gas could only be considered. Finally, the effect of sloshing on the amount of heat exchange between liquid and gas hydrogen was discussed. Considering the heat ingress into liquid hydrogen according to the presence/absence of a sloshing excitation, the amount of heat flux and BOG were discussed for each filling ratio.

Study of the Characteristics of Hydrogen-Gas Filling Process of Ultra-Light Composite Tanks for Fuel-Cell Vehicles (연료전지자동차용 초경량 복합재료 탱크의 수소 충전 특성 연구)

  • Yoo, Gye-Hyoung;Kim, Jong-Lyul;Lee, Taek-Su;Lee, Joong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.813-819
    • /
    • 2011
  • In this research, we investigated the hydrogen-gas filling characteristics of ultra-light composite tanks that have a plastic or aluminum liner inside the composite shell. The study was performed for different gas and tank temperatures. The temperature changes at various positions in the Type-4 tank during hydrogen-gas filling were monitored in order to understand the effects of the filling conditions. The results were compared with those obtained for a Type-3 tank. As the filling speed was increased, a quicker temperature rise was observed, and the temperature distribution over the entire region showed significant discrepancies.

Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection (코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, the stress and deformation characteristics of corner protection in which is fabricated in an insulation area have been analyzed using a finite element method. The proposed corner protection may increase the strength and leakage safeties of conventional LNG storage system. The stress and deformation of LNG storage tank system are computed for an insulation panel box, membrane inner tank, and prestressed concrete outer tank. The FEM computed results indicate that the stress and displacement of new membrane LNG tank system with a corner protection between an inner tank and an outer tank are reduced in comparison to those of a conventional membrane LNG tank. This is explained that the strength safety of LNG membrane tank system may be increased due to a strength stiffness of a corner protection.

  • PDF

Cause Analysis of Cone Roof Tank Collapse during Plant Construction (플랜트 공사 중 발생한 Cone Roof Tank 붕괴 사고 원인 분석)

  • Kim, Seung-Han;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • This study is on safety improvement measures through analysis of accident cases during plant storage tank construction. Storage tank is a general term for artificial ground facility constructed to store oil, water, gas, and other chemicals. Some companies have clustered storage tanks (tank farm). The construction methods vary according to the component and types of fluids. Because most of the construction procedures include lifting heavy weight materials using heavy construction equipment and are carried out at high places, storage tank construction contains more risk factors than normal aerial construction. Recently, major accidents such as storage tank collapse have occurred often, and cost many lives due to the characteristics of the structure. In this study we would like to analyze the cause of these accidents and propose measures to improve safety.

Flow analysis of fermenter, digester and dryer environmental in energy facilities (환경 에너지 시설 내 발효조, 소화기 및 건조기 유동해석)

  • Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.13 no.4
    • /
    • pp.28-33
    • /
    • 2019
  • In this study, the flow analysis of fermentation tank, digester and dryer, which are the main equipment in environmental energy facilities, was carried out. Numerical analysis was carried out with the size of the actual plant, and 3D modeling program CATIA V5 R16, grid generation program Gambit, and general purpose flow analysis package ANSYS-FLUENT (v13) were used. Simulation results of the carrier gas flow analysis in the STD dryer using the computational fluid dynamics program showed that the carrier gas smoothly circulated between the shells of the dryer and the flow was uniformly distributed without stagnation or flow. It is also predicted that rotational flow due to shell rotation is active. The average flow velocity of carrier gas in the STD dryer was estimated to be about 0.196m / s, and the average temperature of the carrier gas was calculated to be 424K. Due to the relatively slow carrier gas velocity and high average temperature, the water content of the sludge can be effectively lowered.

The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (I) (기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(I))

  • Kim Y.K.;Hong S.H,;Oh B.T.;Yoon I.S.;Kim J.H.;Kim S.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.13-17
    • /
    • 2003
  • A membrane unit for Liquefied Natural Gas (LNG) storage tank is a structural member which is designed specifically for preventing undesirable LNG leakage. Membrane units have to endure gas and liquid pressures by LNG and thermal stresses by the contact with cryogenic liquid of $-162^{\circ}C$. It is of importance to assure the strengths of membrane by experimental stress analysis under the temperature of LNG. In this paper, we proposed measurement system using commercial electrical strain gage and mechanical extension meter designed for this study.

  • PDF

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • v.5 no.2
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

Experimental Analysis of Corbel Part Behaviour in Inground LNG Storage Tank (지하식 저장탱크 Corbel부 실험적 거동 분석)

  • Yoon I.S.;Kim J.K.;Kim Y.K.;Kim J.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.56-60
    • /
    • 2006
  • The connection part (corbel) between bottom slab and side wall in inground LNG storage tank has hinge conditions partly fixed by using anchor bars to reduce stress concentration. The corbel deforms in both radial and vertical directions under load conditions of the LNG tank such as LNG temperature, hydraulic pressure, etc. Membrane is an important part from the viewpoint of design because the deformation of the corbel is transformed directly to the membrane and superposed with other deformations. Behavior of the corbel has been investigated through various sensors to measure temperature, load and displacement. And the test data have been compared with finite element results analysis to propose a more reasonable design of LNG storage tank.

  • PDF