• Title/Summary/Keyword: Gas Supply

Search Result 1,269, Processing Time 0.031 seconds

Experimental Results of New Ion Source for Performance Test

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

Sexual Behavior and Sex Pheromone Gland of the Apple Leafminer, Phyllonorycter ringoniella(Lepidoptera: Gracillariidae) (사과굴나방(Phyllonorycter ringoniella)의 생식행동과 성페로몬샘 구조)

  • 정창훈;부경생
    • Korean journal of applied entomology
    • /
    • v.36 no.4
    • /
    • pp.323-330
    • /
    • 1997
  • The apple leafminer, Phyllonorycrer ringoniella (Lepidoptera: Gracillariidae), is the most important pest on apple leaves and is not easy to be controlled with insecticides because of leafmining habit of its larvae. This study was undertaken to develop an artificial diet for mass rearing of the moth, and to look at their reproductive behavior. For developing an artificial diet the problem of diet contamination with microorganisms and how to supply artificial diet to first instar larvae have to be solved first. Artificial oviposition trial was successful with shadowy bottomside of various papers sprayed with apple leaf extracts. The highest activity of both calling and mating was observed within 30 min. after the onset of photophase and 3- to 4-day -old adults showed the highest mating rate. A ring-shaped sex pheromone gland was found at the intersegmental membrane between the 8th and 9th abdominal segments of the female. (E, 2)-4,lOtetradecadienyl acetate was identified as the major component from the femall gland extracts by the gas chromatography (GC) and GC-mass spectrometry. Additionally it was thought that (a-10-tetradecenyl acetate could be the second component of their sex pheromone.

  • PDF

Concise Bedside Surgical Management of Profound Reperfusion Injury after Vascular Reconstruction in Severe Trauma Patient: Case Report

  • Chung, Hoe Jeong;Kim, Seong-yup;Byun, Chun Sung;Kwon, Ki-Youn;Jung, Pil Young
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.204-208
    • /
    • 2016
  • For an orthopaedic surgeon, the critical decisions to either amputate or salvage a limb with severe crushing injury with progressive ischemic change due to arterial rupture or occlusion can become a clinical dilemma at the Emergency Department (ED). And reperfusion injury is one of the fetal complications after vascular reconstruction. The authors present a case which was able to save patient's life by rapid vessel ligation at bedside to prevent severe reperfusion injury. A 43-year-old male patient with no pre-existing medical conditions was transported by helicopter to Level I trauma center from incident scene. Initial result of extended focused assessment with sonography for trauma (eFAST) was negative. The trauma series X-rays at the trauma bay of ED showed a multiple contiguous rib fractures with hemothorax and his pelvic radiograph revealed a complex pelvic trauma of an Anterior Posterior Compression (APC) Type II. Lower extremity computed tomography showed a discontinuity in common femoral artery at the fracture site and no distal run off. Surgical finding revealed a complete rupture of common femoral artery and vein around the fracture site. But due to the age aspect of the patient, the operating team decided a vascular repair rather than amputation even if the anticipated reperfusion time was 7 hours from the onset of trauma. Only two hours after the reperfusion, the patient was in a state of shock when his arterial blood gas analysis (ABGA) showed a drop of pH from 7.32 to 7.18. An imminent bedside procedure of aseptic opening the surgical site and clamping the anastomosis site was taken place rather than undergoing a surgery of amputation because of ultimately unstable vital sign. The authors would like to emphasize the importance of rapid decision making and prompt vessel ligation which supply blood flow to the ischemic limb to increase the survival rate in case of profound reperfusion injury.

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.

Changes in the Concentrations of the Tap Water Chlorination By-Products by Heating during Cooking, and Human Ingestion Exposure (조리시 가열에 따른 수돗물 중 염소소독부산물의 농도 변화와 인체 섭취 노출)

  • 김희갑;이수형
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.1_2
    • /
    • pp.35-43
    • /
    • 1999
  • A number of disinfection by-products (DBPs) are formed as a result of the addition of chlorine into the public water supply and some of them have been suggested to cause adverse health effects on humans. However, the estimation of human ingestion exposure to each DBP has been performed simply by multiplying the concentration of a chemical in the cold tap water by the volume of water consumed during a given period of time. However, a questionnaire concerning water consumptions administered to sixty people residing in Chunchon showed that the volume of tap water consumed accounted for approximately 70% of the total volume of water consumed and that of heated water represented approximately 94% of tap water ingested. Heating durations for water-containing foods (e. g., soups and pot stews) and heated beverages (e. g., barley tea) were grouped into 10, 20, 30, and 35 minutes. Based on these time frames, an aluminum pot containing one liter of tap water was heated for the above respective time periods using a gas range to determine the variations of the concentrations of individual DBPs by heating. The pH and total residual chlorine were measured before and after heating. Collected water samples were carried to the laboratory and analyzed for eight DBPs and total organic carbon. Chloroform, bromodichloromethane, chloral hydrate, 1, 2-dichloro-2-propanone, 1, 1, 1-trichloropropanone, and dichloroacetonitrile were not detected following heating for 10 minutes and longer. The concentration of dichloroacetic acid (DCAA) was elevated with heating duration, resulting in the averages of 2.0, 3.1, 4.7, and 12 times the initial concentration, respectively, for 10, 20, 30, and 35 minute heating periods. On the other hand, the concentration of trichloroacetic acid (TCAA) decreased with heating duration, with 0.65, 0.40, 0.34, and 0.19 times lower than the initial concentration. Therefore, it is suggested that ingestion exposure to DCAA increases with heating duration but that ingestion exposure to TCAA decreases. In addition, while the amount of DCAA was elevated at the initial time periods (10 or 20 minutes) and then slowly decreased, that of TCAA was rapidly decreased. In conclusion, water-heating processes during cooking influence the concentrations of individual DBPs in the tap water, with lower levels for volatile DBPs and TCAA, and higher levels for DCAA. Therefore, concentration change needs to be taken into consideration in the estimation of human ingestion exposure to DBPs.

  • PDF

A Study on Effect of a Combined Plasma EGR System upon Soot CO and $CO_2$ Emissions in Turbo Intercooler Common-rail Diesel Engines (터보 인터쿨러 커먼레일 디젤기관의 매연, CO 및 $CO_2$ 배출물에 미치는 플라즈마 EGR 조합시스템의 영향에 관한 연구)

  • Bae, Myung-Whan;Ku, Young-Jin;Lee, Bong-Sub;Youn, Il-Joong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.1-11
    • /
    • 2006
  • The aim in this study is to develop the combined EGR system with a non-thermal plasma reactor for reducing exhaust emissions and improving fuel economy in turbo intercooler ECU common-rail diesel engines. In this study, the characteristics of soot, CO and $CO_2$ emissions under four kinds of engine loads are experimentally investigated by using a four-cycle, four-cylinder, direct injection type, water-cooled turbo intercooler ECU common-rail diesel engine with a combined plasma exhaust gas recirculation(EGR) system operating at three kinds of engine speeds. The EGR and non-thermal plasma reactor system are used to reduce $NO_x$ emissions, and the non-thermal plasma reactor and turbo intercooler system are used to reduce soot and THC emissions. The plasma system is a flat-to-flat type reactor operated by a plasma power supply. The fuel is sprayed by pilot and main injections at the variable injection timing between BTDC $15^{\circ}$ and ATDC $1^{\circ}$ according to experimental conditions. It is found that soot emissions with increasing EGR rate are increased, but are decreased as the applied electrical voltage of the non-thermal plasma reactor is elevated at the same engine speed and load. Results also show that CO and $CO_2$ emissions are increased as EGR rate is elevated, and CO emissions are increased, but $CO_2$ emissions are decreased as the applied electrical voltage of the non-thermal plasma reactor is elevated at the same engine speed and load.

Oxygen Transfer System in Biological Fluidised Bed Using the Deep Shaft as Aeration Device (생물학적(生物學的) 유동층(流動層)을 이용(利用)한 폐수처리(廢水處理)에 있어서의 심층(深層) 폭기장치(曝氣裝置)에 의한 산소전달(酸素傳達) 시스템)

  • Kim, Hwan Gi;Ahn, Song Yeob;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.13-24
    • /
    • 1988
  • This paper is concentrated on the development of oxygen transfer system by U-tube deep shaft in biological fluidised bed process. The depth of the shaft is 32 m, it is composed of downcomer and riser. Not only flow pattern and oxygen transfer in the deep shaft but also oxygen limitation in biofilm and oxygen utilization in biological fluidised bed are investigated. In this investigation, driving force for liquid circulation in the deep shaft is affected by air injection depth and gas hold-up in downcomer. Flow pattern of the deep shaft is revealed to plug flow. When flow velocity in the deep shaft is maintained to 0.52 m/sec, $K_La$ value is peak at 25~30 m depth in riser. The efficiency of dissolved oxygen supply which passed from the deep shaft to biological fluidised bed is estimated to 56~81 % in the organic wastewater treatment using the deep shaft and when dissolved oxygen concentration is 9.2 mg/l and over, limiting factors of flux and substrate within biofilm are organic materials. Terefore, organic loadings could be increase without decreasing of BOD removal efficiency.

  • PDF

Combustion Characteristics of CH4 Nonpremixed Flame with Recession Distance (메탄 비예혼합 화염의 후퇴거리에 따른 연소특성)

  • Kim, Jun-Hee;Ku, Kun-Woo;Hong, Jung-Goo;Lee, Choong-Won;Kim, In-Su;Cheong, In-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.285-291
    • /
    • 2012
  • A lot of research on the stability of nonpremixed flames has focused on the fuel-nozzle and quarl geometries. Of the work carried out, only a small amount has focused on the stability of the nonpremixed flame according to the recession distance and air-nozzle geometry. Therefore, in this study, a coaxial-diffusion-type gas burner with a swirler is designed for the systematic investigation of the combustion characteristics of a $CH_4$ flame depending on the recession distance and secondary air-nozzle geometry. 1st air is flowed through the swirler, and 2nd air is flowed through each nozzle. It is shown that the secondary air velocity greatly influences the flame length and shape. There is an optimum recession distance for each nozzle for the best combustion efficiency. In this study, it is shown that the optimized recession distance is nearly half the outer diameter of the air-supply nozzle.

A System Simulation Model of Proton Exchange Membrane Fuel Cell for Residential Power Generation for Thermal Management Study (가정용 연료전지 시스템의 열관리 해석을 위한 시스템 운전 모델 개발)

  • Yu, Sang-Seok;Lee, Young-Duk;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.19-26
    • /
    • 2010
  • A PEMFC(proton exchange membrane fuel cell) is a good candidate for residential power generation to be coped with the shortage of fossil fuel and green house gas emission. The attractive benefit of the PEMFC is to produce electric power as well as hot water for home usage. The thermal management of PEMFC for RPG is to utilize the heat of PEMFC so that the PEMFC can be operated at its optimal efficiency. In this study, thermal management system of PEMFC stack is modeled to understand the dynamic response during load change. The thermal management system of PEMFC for RPGFC is composed of two cooling circuits, one for controling the fuel cell temperature and the other for heating up the water for home usage. The different operating strategy is applied for each cooling circuit considering the duty of those two circuits. Even though the capacity of PEMFC system (1kW) is enough to supply hot domestic water for residence, heat-up of reservior takes some hours. Therefore, in this study, time schedule of the simulation reflects the heat-up process. Dynamic responses and operating strategies of the PEMFC system are investigated during load changes.

Repeated Fed-Batch Fermentation of Wheat Flour Solution by Mixed Lactic Acid Bacteria (혼합 젖산균을 이용한 밀가루 용액의 반복 유가식 발효)

  • Kim, Sang-Yong;Noh, Bong-Soo;Oh, Deok-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.343-347
    • /
    • 1997
  • Effect of culture conditions on the fermentation of wheat flour solution by mixed lactic acid bacteria of Lactobacillus brevis, L. fermentum and L. plantarum was investigated. The optimum temperature for the fermentation of wheat flour solution was $35^{\circ}C$ because pH decreased the lowest value and TTA (total titrable acidity) increased the highest value at this temperature. In aerobic condition, fermentor was purged with air at 1.0 vvm and was purged with nitrogen gas at 1.0 vvm in anaerobic condition. The decrease of pH and the increase of TTA in aerobic condition were higher than those in anaerobic condition. In aerobic condition, the optimum condition of oxygen supply was found to be oxygen transfer rate coefficient of $60\;hr^{-1}$ which corresponded to agitation speed of 250 rpm in a 5 L fermentor. Repeated fed-batch cultures were performed using pH-stat in order to increase the productivity of fermented wheat flour. With increasing the repeated fraction of culture volume, mean cycle time increased but maximum operation time decreased. However, the volume of produced broth per culture volume per time and total volume of produced broth per culture volume were maximum at the repeated fraction of culture volume of 20%. In a repeated fed-batch fermentation of wheat flour solution using mixed lactic acid bacteria, the culture condition was optimum at temerature of $35^{\circ}C$, aeration rate of 1.0 vvm, oxygen transfer rate coefficient of $60\;hr^{-1}$, and repeated fraction of culture volume of 20%.

  • PDF