• Title/Summary/Keyword: Gas Station

Search Result 475, Processing Time 0.025 seconds

A Study on the Calculation and Application of the Risk in the Hydrogen Stations (수소충전소의 위험도 산출 및 적용에 대한 고찰)

  • Seo, Doo-Hyoun;Kim, Tae-Hun;Rhi, Kwang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.1-9
    • /
    • 2020
  • In Korea, hydrogen stations are being promoted and commercialized. However, the risk assessment for the hydrogen station is not clear. In particular, it is not clear how to calculate the risk and acceptable criteria for a hydrogen station. Therefore, in this study, three hydrogen stations being installed were selected and general risks were calculated and the social risk of each hydrogen station was calculated. In general, the method of risk assessment is individual/social risk. This is an individual's death rate considering the frequency of accidents, And the likelihood of death according to the number of nearby residents. These can be used to calculate the level of risk for a hydrogen station. However, this method of calculate risks is the criteria for judging whether it is acceptable are unclear. For this reason, this study investigated the allowable standards for foreign risks and considered that they were acceptable by applying the risks of selected domestic hydrogen stations.

Genotoxic Effects on Gas Station Attendants in South-southeastern México due to Prolonged and Chronic Exposure to Gasoline

  • Rebeca I. Martinez-Salinas;Irene Sanchez-Moreno;Juan J. Morales Lopez;Benito Salvatierra Izaba;Everardo Barba Macias;Anahi Armas-Tizapantzi;Arturo Torres-Dosal
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.236-241
    • /
    • 2024
  • Background: Gasoline, a complex mixture of volatile organic compounds is classified as possibly carcinogenic to humans. Gasoline station attendants, consistently exposed to its hazardous components, may face genotoxic effects. This study aimed to assess the influence of varying work shift durations on DNA damage in gasoline station attendants. Methods: Ninety individuals from three locations in southern México were studied. Peripheral blood mononuclear cells (PBMCs) were isolated, and DNA damage was assessed using the comet assay. Demographic, occupational, and lifestyle data were collected. Statistical analyses included t-tests, ANOVA, and Pearson correlation. Results: Significant differences in DNA damage parameters were observed between exposed and unexposed groups. The impact of tobacco, alcohol, and exercise on DNA damage was negligible. Extended work shifts (12 and 24 hours) showed heightened DNA damage compared to 8-hour shifts and the unexposed group. A novel finding revealed a modest but significant correlation between DNA damage and job seniority. Conclusion: The study highlights the intricate relationship between occupational exposure to gasoline components, DNA damage, and work shift lengths. Extended shifts correlate with heightened genotoxic effects, emphasizing the importance of personalized safety measures. The significant correlation between DNA damage and job seniority introduces occupational longevity as a determinant in the genetic health of gasoline station attendants. This discovery has implications for implementing targeted interventions and preventive strategies to safeguard workers' genetic integrity throughout their years of service. The study calls for further exploration of unconsidered factors in understanding the multifactorial nature of DNA damage in this occupational setting.

The Quantitative Risk Analysis in Rail Transport of Propylene (프로필렌의 철도 수송에 따른 정량적 위험성 평가)

  • Lee, Jae-Hean;Song, Dong-Woo;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.38-44
    • /
    • 2010
  • This treatise analyzed the risk of propylene transported by railroad through quantitative analysis. As a result of survey on propylene transportation route, Iksan station, Suncheon station and Jeonju station were selected as object regions those were expected to have high accident risks. This treatise deduced the scenario of accident and the occurrence rate in accordance with the type of accident possibly to be happening during propylene transportation through ETA( Event Tree Analysis), and expressed the level of personal, social risks after calculating the level of demage influencing over surroundings based on the evaluation for the expected accident damage through PHAST 6.53.

Development of $20\;Nm^3$/hr Hydrogen Generator for Hydrogen Fueling Station (수소스테이션용 $20\;Nm^3$/hr급 수소제조장치 개발)

  • Oh, Young-Sam;Baek, Young-Soon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • In this study, $20\;Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was manufactured and tested. The design of $20\;Nm^3/hr$ scale compact hydrogen generator was upgraded on the base of $5\;Nm^3/hr$ scale plate hydrogen generator concept stacking the plate reactors. Ideas for improving system efficiency such as heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor, reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design etc. were applied. From the performance test, we can learn that the $20\;Nm^3/hr$ scale compact hydrogen generator can be operated steadily at 100% road condition and the methane conversion of over 94%(at S/C=3.75) was obtained. This result shows that the concept of plate type hydrogen generator can be scale-up to the $20\;Nm^3/hr$ scale and fit for hydrogen generator for on site hydrogen station application.

Consequence Analysis of Hydrogen Filling Stations based on Cascade Compressing Systems (케스케이드 방식 압축시스템 기반의 수소충전소에 대한 정성적 위험성평가)

  • Ahn, Byeong-Jun;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.13-21
    • /
    • 2021
  • Because of the recent expansion of hydrogen vehicle supply, the installation of hydrogen filling station is expected to gradually expand. This study attempts to predict the damage scale and propose a safer design form based on the scenario that assumes the worst case of a hydrogen station. A Flacs solver using computational fluid dynamics (CFD) was used to predict the damage scale, and the accuracy was verified by comparing it with the experimental results of previous researchers. The damage scale prediction was conducted for hydrogen leakage and explosion, and the prediction target was the KR model based on the measured values. And as a comparative review model, a roofless model was selected without a ceiling. As a result of analyzing the two models, it was possible to confirm the accumulation and retention of hydrogen gas up to 60 vol% or more in the KR model, whereas in the case of the Roofless model, the phenomenon of discharge and diffusion to the outside of the charging station by riding the wall after leakage. I was able to check. In conclusion, it was reviewed that the type of hydrogen charging station without ceiling is more advantageous for safety than the hydrogen filling station model.

Quantitative Safety Assessment for Hydrogen Station Dispenser (수소 충전소 충전기의 정량적 안전성 평가)

  • Rhie, Kwang-Won;Kim, Tae-Hun;Lee, Taeck-Hong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.3
    • /
    • pp.272-278
    • /
    • 2006
  • This study is quantitatively assessing of safety about dispenser of hydrogen station because it is hydrogen energy to efficient safety use. The large leakage of hydrogen gas is the most important accident among others occurrence possibility in hydrogen station. It had written FT by top event and calculated unavailability, m-cutsets, leakage frequency, etc with FTA after each base event collect reliability data by reliability data handbook, THERP-HRA and estimation of the engineering.

Development of the Safety Cabinet for Respiratory High-Pressure cylinder according to Consequence Analysis of Physical Explosion Damage (호흡용 고압용기 파열 피해영향 분석에 따른 안전충전함 개발)

  • Jang, Kap Man;Kim, Jeong Hwan;Jang, Yu Ri;Lee, Jin Han;Jo, Young Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.80-88
    • /
    • 2016
  • A fire station and scuba have operated filling facilities for respiratory high-pressure cylinder without getting authority or reporting according to High-Pressure Gas Safety Control Act. They need facility improvement and special management to make provision for the time of accident during filling process. The Government have strived to correct illegal operations and suggested an alternative, establishing and operating the safety cabinet. It insures a safety being distance from danger caused by overpressure and a safety provoked by the protective wall equals or superiors. The safety cabinet is required to have an internal structure that smoothly distribute overpressure at the time of rupture. Plus, it needs to minimize fragments. It is also equipped with the performance of protective wall that makes overpressure to outside vent on the place where there is no person (top or bottom). This study calculated the consequence of physical explosion damage and built a prototype of safety cabinet. In addition, through the gas burst test, it derives for the ways to mitigate the physical explosion damage.

Experimental Study on the Designed Ventilation Effect on the Smoke Movement at Rescue Station fire in Railway Tunnel (터널 내 화재발생시 구난역 내의 연기 거동에 미치는 설계된 환기 영향에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.163-167
    • /
    • 2008
  • In this study, the 1/35 reduced-scale model experiment were conducted to investigate designed ventilation effect on the smoke movement at rescue station fire in railway tunnel. A model tunnel with 2 mm thick, 10 m long, 0.19 m high and 0.26 m was made by using Froude number scaling law. The cross-passages installing escape door at the center were connected between incident tunnel and rescue tunnel. The n-heptane pool fires with heat release rate 698.97W were used as fire source. The fire source was located at the center and portal of incident tunnel as worst case. A operating ventilation system extracted smoke amount of 0.015 cms(cubic meters per second). The smoke temperature and CO gas concentration in cross-passage were measured to verify designed ventilation system. The result showed that, at center fire case without ventilation, smoke did not propagate to rescues station. In portal fire case, smoke spreaded to rescues station without ventilation. But smoke did not propagated to rescues station with designed ventilation.

  • PDF