• Title/Summary/Keyword: Gas Spring

Search Result 219, Processing Time 0.03 seconds

Estimation of the Spring and Summer Net Community Production in the Ulleung Basin using Machine Learning Methods (기계학습법을 이용한 동해 울릉분지의 봄과 여름 순군집생산 추정)

  • DOSHIK HAHM;INHEE LEE;MINKI CHOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.29 no.1
    • /
    • pp.1-13
    • /
    • 2024
  • The southwestern part of the East Sea is known to have a high primary productivity compared to those in the northern and eastern parts, which is attributed to nutrients supplies either by Tsushima Warm Current or by coastal upwelling. However, research on the biological pump in this area is limited. We developed machine learning models to estimate net community production (NCP), a measure of biological pump, with high spatial and time scales of 4 km and 8 days, respectively. The models were fed with the input parameters of sea surface temperature, chlorophyll-a, mixed layer depths, and photosynthetically active radiation and trained with observed NCP derived from high resolution measurements of surface O2/Ar. The root mean square error between the predicted values by the best performing machine model and the observed NCP was 6 mmol O2 m-2 d-1, corresponding to 15% of the average of observed NCP. The NCP in the central part of the Ulleung Basin was highest in March at 49 mmol O2 m-2 d-1 and lowest in June and July at 18 mmol O2 m-2 d-1. These seasonal variations were similar to the vertical nitrate flux based on the 3He gas exchange rate and to the particulate organic carbon flux estimated by the 234Th disequilibrium method. To expand this method, which produces NCP estimate for spring and summer, to autumn and winter, it is necessary to devise a way to correct bias in NCP by the entrainment of subsurface waters during the seasons.

A Study on the Design of the Free-Piston Stirling Engine/Alternator (자유 피스톤 스털링엔진/발전기의 설계 인자 연구)

  • Park, Seongje;Hong, Yongju;Ko, Junseok;Kim, Hyobong;Yeom, Hankil;In, Sehwan;Kang, Insu;Lee, Cheongsu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.6
    • /
    • pp.648-655
    • /
    • 2014
  • This paper describes the continuing effort to develope a single acting free-piston Stirling engine/alternator combination for use of the household cogeneration. Free piston Stirling engines(FPSE) use variations of working gas pressure to drive mechanically unconstrained reciprocating elements. Stirling cycle free-piston engines are driven by the Stirling thermodynamic cycle which is characterized by an externally heated device containing working gas that is continuously re-used in a regenerative, reversible cycle. The ideal cycle is described by two isothermal process connected by two constant volume processes. Heat removed during the constant volume cooling process is internally transferred to the constant volume heating process by mutual use of a thermal storage medium called the regenerator. Since the ideal cycle is reversible, the ideal efficiency is that of Carnot. Free-piston Stirling engine is have no crank and rotating parts to generate lateral forces and require lubrication. The FPSE is typically comprised of two oscillating pistons contained in a common cylinder. The temperature difference across the displacer maintains the oscillations, and the FPSE operate at natural frequency of the mass-spring system. The power is generated from a linear alternator. The purpose of this paper is to describe the design process of the single acting free-piston Stirling engine/alternator. Electrical output of the single acting free-piston Stirling engine/alternator is about 0.95 kW.

Study on Seasonal Variation Characteristics of Forest Phytoncide in Ulsan Metropolitan Trails (계절에 따른 울산지역 산책로의 피톤치드 특성연구)

  • Park, Heung Jai;Yu, Bong Gwan;Park, Sun Ho;Lee, Jin Yeol;Hahm, Yoo Sik;Jeong, Seong Wook;Byeon, Ki Yeong;Kim, So Hee;Jung, Im Su;Lee, Mi Lim
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1415-1419
    • /
    • 2013
  • This study was conducted to investigate the seasonal variation characteristics of phytoncide in trail of Ulsan Metropolitan. Air samples were collected from May to December 2011. They were collected using Tenax Ta tube and phytoncides were detected and quantified using a Gas Chromatograph Mass Spectrometer (GC/MSD). This study are summarized as follows; The seasonal concentrations of phytoncide are Munsu Mt. 272.3 ${\mu}g/m^3$, Samho Mt. 192.4 ${\mu}g/m^3$, Shinbul Mt. 50.9 ${\mu}g/m^3$, Sibli Bamboo forest 22.4 ${\mu}g/m^3$ and Joongbu Fire Station 24.4 ${\mu}g/m^3$. In Munsu Mt., Samho Mt. and Shinbul Mt. major component ratio is ${\alpha}$-Pinene > ${\beta}$-Pinene+Myrcene >Limonene >Camphene > ${\gamma}$-Terpinene > ${\alpha}$-Terpinene. Bamboo forest and Joongbu fire station major component ratio is ${\alpha}$-Pinene >Limonene > ${\beta}$-Pinene+Myrcene >Camphene > ${\alpha}$-Terpinene. The variation of seasonal concentration is summer >spring >fall >winter. The phytoncide concentration of coniferous forest(Munsu Mt., Samho Mt.) is higher than broadleaf forest(Shinbul Mt.).

A Study on Design of the Linear Generator in the Double Acting Stirling Engine (양방향 스털링엔진의 선형발전기 설계에 관한 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.638-644
    • /
    • 2015
  • This paper describes the continuing effort to analysis and design on dynamic and electrical behavior of gamma-type free piston Stirling engine/generator with dual-opposed linear generator for domestic micro-CHP (Combined Heat and Power) system. The double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric sinusoidal displacement and are connected with moving magnet type linear generators for power generation. To operate Stirling engine/generator, combustion heat of natural gas is supplied to hot-end and heat is rejected from cold-end by cooling water. The temperature difference across the displacer induces the oscillating motion, and it can be explained with mass-spring vibration system. The purpose of this paper is to describe the design process of linear generator for the double acting free-piston Stirling engine.

Characteristics of Contamination and Fate for PCDD/Fs in Ambient Air, Cheongju (청주지역 대기 중 PCDD/Fs 오염특성 및 거동)

  • Kim, Kyoung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.294-299
    • /
    • 2009
  • To investigate the pollution levels and behavior of PCDD/Fs in ambient air, gaseous and particulate phase concentrations were measured at Cheongju city in 2008. The samples were collected at 3 sites (industrial, residential/commercial and rural region) by season (winter, spring and summer). The concentrations and TEQ concentrations of PCDD/DFs ranged from 0.73 to 2.43 pg/$m^3$ and from 0.007 to 0.122 pg TEQ/$m^3$, respectively. These levels were similar or lower than that of other domestic researches (from n.d. to 2.149 pg TEQ/$m^3$). The concentration of PCDD/Fs in particulate phase (from 54% to 98% against total concentration) were higher than that of gas phase. As a results of comparison of congener patterns and statistical analysis, PCDD/Fs was mainly influenced by a combustion process in ambient air, Cheongju city.

Composition of Organic Compounds in the Ambient PM10 of the Anmyon Island (안면도 미세먼지 내 유기성분들의 분포 특성)

  • Lee, Ji Yi;Hwang, Eun Jin;Lim, Hyung Bae;Kim, Yu Won;Kim, Eun Sil;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.187-197
    • /
    • 2013
  • To understand the characteristics of organic aerosol(OA) at the background atmosphere of Korea, an observation of atmospheric PM10 was conducted at a Global Atmospheric Watch(GAW) station operated by the Korean Meteorological Administration at Anmyon Island during 2010. Various organic compounds were analyzed from 26 samples by using a gas chromatography-mass spectrometer. Water soluble organic carbon(WSOC) was also analyzed by using a total organic carbon(TOC) analyzer. Among 6 classes with 68 target compounds detected, the classes of n-alkanoic and alkenoic acids ($326.67{\pm}75.40ngm^{-3}$) and dicarboxylic acids ($323.74{\pm}361.89ngm^{-3}$) were found to be major compound classes in the atmosphere of Anmyon Island. Compared to the previous results reported for 2005 spring samples at Gosan site, the concentrations of organic compounds at Anmyon Island were 3-10 times higher than Gosan site due to the difference of location and sampling period. The concentrations of organic compounds were varied with the atmospheric conditions. Significant increase of the concentrations of dicarboxylic and carboxylic acids in the smog episode indicated that secondary oxidation of organic compounds was major factor to increase OA concentration during smog episode in the Anmyon Island. It was found that the compositions of the OA measured at Anmyon Island were dependent on the air parcel trajectories.

A Study on the Elderly Households' Needs for Housing Modification (노인가구 특성에 따른 주거개조요구에 관한 연구)

  • Lee, Kwang-Soo;Park, Soo-Been
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.278-283
    • /
    • 2009
  • This study aims to figure out the old people's needs for modification of their housing to maintain an independent lifestyle despite their health status and living arrangements. The total of 438 residents take part in the questionnaire survey research through the quota sampling method grouped by age (60-64 group, 65-69 group, 70-74 group, and over 75 group), sex (male and female), and house type (apartment houses and others). The results are as follows. (1) The old people's most inspired modification needs in interior spaces are remodeling the heating controls in the living room and the bedroom, ventilation facilities and storage spaces in the kitchen, non-slip tile flooring and ventilation facilities in bathroom, an easy door-lock, non-slip tile flooring, a draft cut-off, and storage spaces in the entrance. Besides they require emergency alarm, easy door and window locks, fire and gas alarm, and furniture with easy handling. It is necessary to supply the aged with the appropriate heating controls for their sensitivity to heat, with enough storage spaces for the increased possessions, and with diverse safety systems reflected blunting of mobility and sensibility. (2) As they grow older, the aged require more remote controls and safety facilities such as emergency alarm, easy locks and furniture with distinguishable colors. Male elderly is more concerned with safety, while female elderly do with convenience due to their different time spending in the house. The elderly residents in the apartment houses require the heating controls, a draft cut-off, and storage space less than other types of houses. Thus modification of the heating controls, a draft cut-off, and storage space are regards as basic needs for the elderly residents in non-apartment houses.

  • PDF

Seasonal Size Distribution of Atmospheric Particles in Iksan, Korea

  • Kang, Gong-Unn;Kim, Nam-Song;Rhim, Kook-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.6
    • /
    • pp.543-555
    • /
    • 2006
  • During a twenty-day period in 2005, a nine-stage Andersen cascade impactor was used to determine the seasonal size distribution of atmospheric particles and its inorganic ion species sampled for 24hr in Iksan city, located southwest of the Korean peninsula. Samples were analyzed for major water-soluble ion species using Dionex-100 ion chromatograph. Average fine and coarse mass concentrations of atmospheric particles were, respectively, 31.4 and $82.6{\mu}g\;m^{-3}$ in spring and 35.8 and $73.4{\mu}g\;m^{-3}$ in fall-winter during the sampling period of 2005, while measurements of 69.8 and 9.9 were obtained in the sampling period of summer, The size distribution of particulate mass concentration during the non-Asian dust period was generally bimodal, whereas the size distribution of particulate mass concentration during the Asian dust period was unimodal due to the significant increase of coarse particles, which originated from long-range transport of soil dust particles from loess regions of the Asian continent. Among ionic species, $SO{_4}^{2-},\;NH{_4}^+,\;K^+$ were mainly distributed in fine particles due to their characteristics of emission sources and gas-to-particle conversion, while $Na^+,\;Mg^{2+}\;and\;Ca^{2+}$ were dominantly in coarse particles. However, $NO_3{^-}\;and\;Cl^-$ were distributed in both coarse particles and fine particles. Although $SO{_4}^{2-}$ was mainly distributed in fine particles, the size distributions of $SO{_4}^{2-}$ in coarse mode were significantly increased during the Asian dust events compared to those during the non-Asian dust period. $Ca^{2+}$ showed the most abundant species in the atmospheric particles during the Asian dust period. $NH{_4}^+$ was found to mainly exist as $(NH_4)_2SO_4$ in fine particles.

A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve (산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰)

  • Lee, JoongYoup;Han, SangYeop;Lee, SooYong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • The oxidizer shutoff valve of a gas generator controls the mass flow rate of the propellant of a rocket engine using pilot pressure and spring the force of the valve. The developing oxidizer shutoff valve can be shut off if the pilot pressure is removed from the actuator. Therefore, force balancing is necessary to analyze the characteristics of the forces with respect to the opening and closing of the valve in order to evaluate its performance. In light of this, the valve has been designed to adjust the control pressure required to open the poppet and to determine the working fluid pressure at which the valve starts to close. Under cryogenic flow test as a tests level of C.R.T(Control Random Test), the chattering phenomena occurred due to much leakage of a metal seat section. The pressure for chattering of the oxidizer valve is predicted at about 11 bar using force balancing analysis.

Variations of Trace Gases Concentrations and Their Relationship with the Air Mass Characteristic at Gosan, Korea (제주도 고산에서의 미량기체 농도변화와 공기괴 특성과의 관계)

  • Kim, In-Ae;Li, Shan-Lan;Kim, Kyung-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.584-593
    • /
    • 2008
  • The surface $O_3,\;CO,\;NO_x,\;and\;SO_2$ were measured at Gosan in Jeju Island from May 2004 to April 2005. Over this period, the mean concentrations $({\pm}s.d.)$ of each gas was 40.06 $({\pm}16.01)$ ppbv for $O_3,\;264.92({\pm}115.73)ppbv\;for\;CO,\;1.98({\pm}2.73)ppbv\;for\;SO)_2,\;and\;4.64 ({\pm}3.24) ppbv\;for\;NO_x$. The monthly variations and the diurnal variations of these gases show that the Gosan site is situated in a relatively clean region. However, there were episodic simultaneous peaks in CO and $SO_2$, especially in winter and early spring. Using cluster analysis with air mass back- ward trajectory analysis, we suggest that these episodes are due to the influence of transportation of polluted air mass from polluted regions. In the cluster, which was under the dominant influence of clean maritime air mass, low levels of $O_3,\;CO,\;and\;SO_2$ were observed. The levels of these species were elevated in the other two clusters which had the air mass influenced by polluted continental regions. In addition, ratios of the chemical species such as $CO/NO_x,\;SO_2/NO_x,\;and\;CO/SO_2$ revealed the somewhat different characteristics of emission sources influencing each cluster. The differences in concentration of trace gases among clusters with different origin and transport pathways imply that Gosan is under the effect of pollution transported from other regions.