• 제목/요약/키워드: Gas Sampling System

검색결과 119건 처리시간 0.032초

TDLAS 시스템을 이용한 유해 배기가스의 농도 계측 (The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System)

  • 차학주;김민수;신명철;김세원;전광민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Wound-State Monitoring for Burn Patients Using E-Nose/SPME System

  • Byun, Hyung-Gi;Persaud, Krishna C.;Pisanelli, Anna Maria
    • ETRI Journal
    • /
    • 제32권3호
    • /
    • pp.440-446
    • /
    • 2010
  • Array-based gas sensors now offer the potential of a robust analytical approach to odor measurement for medical use. We are developing a fast reliable method for detection of microbial infection by monitoring the headspace from the infected wound. In this paper, we present initial results obtained from wound-state monitoring for burn patients using an electronic nose incorporating an automated solid-phase microextraction (SPME) desorption system to enable the system to be used for clinical validation. SPME preconcentration is used for sampling of the headspace air and the response of the sensor module to variable concentrations of volatiles emitted from SPME fiber is evaluated. Gas chromatography-mass spectrometry studies prove that living bacteria, the typical infectious agents in clinical practice, can be distinguished from each other by means of a limited set of key volatile products. Principal component analysis results give the first indication that infected patients may be distinguished from uninfected patients. Microbial laboratory analysis using clinical samples verifies the performance of the system.

하수처리 공정별 아산화질소(N$_2$O) 배출계수 산정 (Estimate of Nitrous Oxide Emission Factors from Municipal Wastewater Treatment Plants)

  • 양형재;박정민;김민정
    • 대한환경공학회지
    • /
    • 제30권12호
    • /
    • pp.1281-1286
    • /
    • 2008
  • 하수처리과정에서 온실가스인 N$_2$O가 발생하는데, N$_2$O의 지구온난화 기여율은 CO$_2$의 310배에 달한다. 본 연구에서는 하수처리공정에 따라 온실가스 배출계수가 어떤 차이를 보이는지를 분석하기위해 운전 중인 4개의 하수처리공정을 대상으로 조사하였다. 배출계수 산정을 위한 시료채취는 Flux Chamber를 이용하였으며, N$_2$O 정량은 6 port gas sampling valve가 장착된 Agilent사의 GC로 분석하였으며, 검출기는 ECD를 사용하였다. 하수처리공정별 오염물질 유입 부하에 대한 N$_2$O 배출계수 산정결과 5-stage공정은 0.94 g-N$_2$O/kg-TN으로 가장 낮았으며, 다음으로 활성슬러지공정이 2.65 g-N$_2$O/kg-TN, Denipho공정이 9.30 g-N$_2$O/kg-TN, 그리고 SBR공정이 26.73 g-N$_2$O/kg-TN으로 가장 높게 나타났다. 하수처리에서 N$_2$O 배출량 감소를 위해서는 조사대상 시설 중 5-stage 공정이 가장 적절한 것으로 평가하였다.

무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구 (A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method)

  • 황성수;오준석;김기동;오영삼;최경식;김학은
    • 한국가스학회지
    • /
    • 제19권1호
    • /
    • pp.12-17
    • /
    • 2015
  • CNG(Compressed Natural Gas)충전소의 주요 핵심설비는 압축기이며, 대부분의 압축기는 윤활이 필요하다. CNG압축기의 윤활유(oil)는 충전 중에 압력 레귤레이터, 엔진 연료공급시스템 등에 전이(Carry-over)되어 천연가스차량의 성능에 부정적인 영향을 미친다. 따라서 이러한 문제를 사전에 방지하기 위해서는 전이되는 오일의 양을 정량적으로 측정하여 공급되는 압축천연가스의 품질관리를 강화하는 것이 필요하다. 본 연구에서는 CNG오일전이를 측정하기 위해 중량법(Gravimetric method)을 사용한 샘플링 튜브 및 샘플링 장비를 개발하였다. 또한, CNG 충전소 6개소를 대상으로 CNG를 채취하였으며, 오일전이를 정량적으로 분석하였다. 측정된 전체 오일전이양은 2.569에서 6.509ppm 이었으며, 측정된 결과를 선행연구 결과와 비교 검증하였다.

GMA용접의 용접신호 모니터링에 관한 연구 (A study on monitoring of welding signals in gas metal arc welding)

  • 신정식;김재웅;나석주
    • Journal of Welding and Joining
    • /
    • 제9권3호
    • /
    • pp.34-40
    • /
    • 1991
  • An automatic welding system was constructed with a personal computer to capture the welding data in addition to vision seam tracking for the gas metal arc welding process. The monitoring of welding signals is composed of the acquisition of welding voltage and current, obtained by using two differential amplifiers and A/D converters, and processing of the measured data. Using interrupt handing circuit for time sharing, two jobs of seam tracking and monitoring were performed at the required sampling time. Relations between welding signals and various welding circumstances were analyzed from the experimental results.

  • PDF

Simultaneous Measurements of Gaseous Nitrous Acid and Particulate Nitrite Using Diffusion Scrubber/Steam Chamber/Luminol Chemiluminescence

  • Chang, Won-Il;Choi, Jung-Ho;Hong, Sang-Bum;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권8호
    • /
    • pp.1525-1532
    • /
    • 2008
  • An instrument was developed for the simultaneous determination of gas- and aerosol-phase nitrous acid (HONO). Gaseous HONO (HONO(g)) was sampled by a diffusion scrubber and particulate nitrite ($NO_2\;^-$(p)) was collected by a particle growth chamber. The collected samples were analyzed in time-sharing manner, based on the peroxynitrite-induced luminol chemiluminescence. The automated system was found to be sensitive with 13 pptv of detection limit, fast with 4 min. of sampling frequency, and simple and affordable to construct and operate. The system was optimized by adjusting the experimental parameters. The system was applied to the field measurement of gas- and particle-phase HONO during the springtime of 2004 in Gwangju, South Korea. HONO(g) concentrations varied diurnally from 200 pptv around 3 P.M. to 800 pptv at 5 A.M. The variation of $NO_2\;^-$(p) was not significant with the maximum of 240 pptv at 11 P.M. and the minimum of 170 pptv at 4 P.M., not displaying distinct characteristics.

온실가스 배출량 산정 방법에 따른 N2O 배출량 비교 (Comparison of N2O Emissions by Greenhouse Gas Emission Estimation Method)

  • 강소영;조창상;김승진;강성민;윤현기;전의찬
    • 한국기후변화학회지
    • /
    • 제6권3호
    • /
    • pp.175-184
    • /
    • 2015
  • In this study GC and PAS were used to calculate $N_2O$ concentration of exhaust gas from Wood Chip combustion system. Fuel supplied to the incinerator was collected and analyzed and then the analysis result was used to calculate $N_2O$ emissions. Tier 3 and Tier 4 Method were used to calculate the $N_2O$ emissions. Plant's Specific emission factor of $N_2O$ by Tier 3 Method was 0.35 kg/TJ, while default emission factor of Wood?Wood Waste proposed by 2006 IPCC G/L was 4 kg/TJ. So the $N_2O$ emission factor of this study was 3.65 kg/TJ lower compared to the IPCC G/L. The total emissions calculated by Plant's specific emission factor was 4.22 kg during the measuring period, but by Tier 4 Method it was 7.88 kg. This difference in emissions was caused by the difference of continuous measuring and intermittent sampling. It would be necessary to apply continuous measuring to calculate emissions of $Non-CO_2$ gas whose the density distribution is relatively high. However currently, according to the target management guideline of greenhouse gas and energy, the continuous measuring method to calculate greenhouse gas emission is applied only to $CO_2$. Therefore for reliable greenhouse gas emission calculation it would be necessary to apply continuous measuring to calculate $Non-CO_2$ gas emission.

LAN을 이용한 혈액가스 검사결과 전송시스템 (Development of Automatic Data Transmitting System of Atrial Blood Gas Results via LAN)

  • 김남현;허재만;김지혜;김도년;김원기;장병철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.103-104
    • /
    • 1992
  • Automatic transmission of data from the blood analyzer to the request site is one of the most important part in hospital computerization. We have developed a system to automatically transmit the data from the atrial blood gas analyzer. In this system, HOST computer, FILE server, LAN(Local Area Network), 3270 Emulator and Multi-port card were integrated. Also, 3 blood gas analyser(NOVA Inc., USA) were connected to a single multi-port card which is attached in a personal computer for data acquisition. When specimen is collected from sampling sites, it is transfered to the lab. After analysis, the result is transmitted to the personal computer via serial communication between machine and multi-port card using interrupt method. Then, the patient's information (Name, Sex, etc.) is obtained from the HOST computer througth the emulator. The combined data(patient information & lab data) is transmitted to the each request site via LAN automatically. From the collected data, patient's previous data could be reviewed, and it could be used for the various statistics and the flow chart for clinical research. Also, we found that this system reduces the personal labor.

  • PDF

LPG 연료계통 부품의 이물질 원인분석에 관한 연구 (A Study on Contaminants Analysis of Components in LPG Fuel System)

  • 김재곤;임의순;정충섭
    • 한국자동차공학회논문집
    • /
    • 제21권3호
    • /
    • pp.126-133
    • /
    • 2013
  • Recently, it was reported that complaints about problems being experienced with the performance of vehicles operating on autogas in Korea. The problem was being assumed due to contaminants in LPG and an oily material which was being deposited in vaporizer, injector in LPG fuel system. This study is focused on the analysis of contaminant of automobile parts on LPG fuel system. The sampling points of contaminants are injectors, fuel filters, vaporizer in automobile equipment and it was also investigated by GC-MS, ICP-AES, SIMDIS and EDS. According to results, it was presumed that this contaminants had been analyzed plasticizers with hydrocarbons with high boiling point, Fe from steel corrosion, greases from gas station.

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E1호
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).