• Title/Summary/Keyword: Gas Sampling System

Search Result 119, Processing Time 0.037 seconds

Aerosol Filtration/Sampling Device Based on Irrigated Rotating Wires

  • M. J. Shaw;M. R. Kuhlman;;J. A. Gieseke
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.265-267
    • /
    • 2000
  • The objective of this study is to analyze, design and evaluate a new gas cleanup or sampling system that will remove erosive, corrosive, and fouling contaminants present in an effluent stream as either solid or liquid particles providing a clean gas stream. The gas clean-up or sampling system considered in this study is an irrigated, rotating element device. The device consists of a central disk-like hub from which emanate radially wires or cylindrical elements. (omitted)

  • PDF

On the Sampling and Transport of Radioactive Aerosols from Waste Thermal Process

  • Yang, Hee-Chul;Kim, Joon-Hyung;Yong Kang
    • Nuclear Engineering and Technology
    • /
    • v.29 no.4
    • /
    • pp.269-279
    • /
    • 1997
  • The errors associated with incorrect sampling and transport of radioactive aerosol from radwaste thermal process off-gas are analyzed and the conditions of representative sampling and correct transport of radioactive aerosol for off-gas system evaluation are discussed. An estimation method of sampling errors for individual radionuclides is proposed and applied to simulated vitrification melter aerosols. Prediction methods for particle deposition in sample transport tube under laminar as well as turbulent flow conditions are also described by example calculations with simulated incinerator off-gas From the results of example calculations and plots, instrumental and operational conditions of radioactive aerosol sampling system with minimized errors and correction methods for nonideal sampling and transport are recommended.

  • PDF

The Use of Gas Chromatograph for the Measurement of Engine Exhaust Gas Composition (엔진 배기가스 성분 측정 을 위한 Gas Chromatograph 의 이용)

  • 김승수;정영교
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.743-749
    • /
    • 1985
  • In this study the usefulness of Gas Chromatograph for the measurement of engine exhaust gas composition was confirmed. It was found that the composition of standard gas which was used for the calibration of Gas Chromatograph should not be greatly different from that of exhaust gas. Although self-evident, it cannot be overemphasized that utmost attention should be paid to prevent even a minute amount of air being mixed into the gas throughout the sampling process.

Procedures for Analyzing Ethylene by Gas Chromatograph (Gas Chromatograph를 이용한 에틸렌 분석 기술)

  • 이승구
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s01
    • /
    • pp.33-39
    • /
    • 1989
  • Ethylene gas classified as one of five major plant hormones plays an important role in various plant metabolism. The precise analysis of ethylene production of plants or plant parts is a valuable research procedure because knowledge of ethylene production facilitates measures of the physiological activity within the tissue. This paper describes procedures for analyzing ethylene from plant tissues by gas chromatography and discusses problems associated with extracting gas samples either by introducing a vacuum to plant samples or by using a hypodermic syringe. Introduced are a continuous flow system for efficient analysis and an automated system for sampling, analyzing, calculating and recording ethylene production data.

  • PDF

Filter-based Correction for Positive Sampling Artifacts in the Determination of Ambient Organic Carbon (여과지를 이용한 유기탄소의 측정 오차 보정)

  • Kang, Byung-Wook;Yeon, Ik-Jun;Cho, Byung-Yeol;Park, Sang-Chan;Lee, Hak-Sung;Jeon, Jun-Min;Na, Kwang-Sam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.63-72
    • /
    • 2011
  • This study describes the impact of positive sampling artifact caused by a filter-based sampling in the determination of ambient organic carbon (OC). Three different sampling media combinations were employed for this investigation: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), and (3) quartz filter and quartz filter behind Teflon filter (Q-QBT). The measurement of ambient OC was carried out at a semi-urban site near oceanside at the end of November of 2008. It was found that Q-alone sampling configuration resulted in a higher OC than QBQ and Q-QBT by 14% and 28%, respectively due to no correction for positive artifact caused by adsorption of gas-phase OC onto the filter. A lower quantity of OC was collected from the backup quartz filter on QBQ than that from Q-QBT. A possible explanation is that the front quartz filter of QBQ was not fully saturated with gas-phase OC during the sampling period, allowing smaller amount of gas-phase OC to reach the backup quartz filter. The contribution of positive artifact to $PM_{2.5}$ mass was approximately 2.15 ${\mu}g/m^3$ which is equivalent to 6% in terms of Q-QBT sampling configuration. The positive artifact was found to be more dominated during summer than during winter, showing temperature dependence. It was concluded that Q-QBT sampling configuration offers less impact of positive artifact on ambient OC sampling than QBQ in quantification of OC.

CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO (하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석)

  • Cho, SungHwan;Lee, JongHyeon;Kim, DaeYoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.327-336
    • /
    • 2020
  • The high-flux advanced neutron application reactor (HANARO) is a research reactor with thermal power of 30 MW applied in various research and development using neutrons generated from uranium fission chain reaction. A degasifier tank is installed in the ancillary facility of HANARO. This facility generates gas pollutants produced owing to internal environmental factors. The degasifier tank is designed to maintain the gas contaminants below acceptable levels and is monitored using an analyzer in the gas sampling panel. If condensate water is generated and flows into the analyzer of the gas sampling panel, corrosion occurs inside the analyzer's measurement chamber, which causes failure. Condensate water is generated because of the temperature difference between the degasifier tank and analyzer when the gas flows into the analyzer. A heating system is installed between the degasifier tank and gas sampling panel to suppress condensate water generation and effectively remove the condensate water inside the system. In this study, we investigated the efficiency of the heating system. In addition, the variations in the pipe temperature and the amount of average condensate water were modeled using a wall condensation model based on the changes in the fluid inlet temperature, outside air temperature, and heating cable-setting temperature.

Development of a Portable Electronic Nose System (I) - System Development - (휴대용 전자코 시스템 개발 (I) - 시스템 개발 -)

  • Lee, Jeong-Woo;Kim, Seong-Min
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.333-339
    • /
    • 2008
  • The purpose of this study was to develop a portable electronic nose system to measure volatile components of agricultural and food products. Also, a graphical operating software to control the electronic nose system and to acquire signals through the Internet was developed. An array of five commercial metal oxide gas sensors was used to detect various volatile gas components of target samples. Transient and steady state signals were analyzed to extract variables related to sample states, To find optimal operating conditions of the system, several experiments were performed with different gas chambers, vacuum pumps, gas sampling temperatures, and sample container sizes. The patterns of gas sensor signals were analysed to find effects of the various conditions.

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF

A Research on the Status of Greenhouse Gas Emission Factors from Livestock Sector to Create a National Greenhouse Gas Inventories (국가 온실가스 인벤토리 축산부문 작성을 위한 온실가스 배출계수 개발 현황에 관한 연구)

  • Lee, Jin Eui;Lee, Hyun Ju;Park, Kyu Hyun;Choi, Byong Yang;Ra, Chang Six
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.21-34
    • /
    • 2011
  • In this study, researches on the development of country specific greenhouse gas measurement and sampling methods from the livestock sector were reviewed. Research on greenhouse gas emission factors was started in early 2000 but was not actively involved in the development of livestock sector based emission factor: since 2009, works are underway for the development of livestock sector based emission factor. Most of the research on greenhouse gas emission in the field of animal studies were done by National Institute of Animal Science, because of the uniqueness of the research laboratories. Methods of emission measurement are still not internationally certified and therefore, measurement and sampling methods for Korea livestock sector are being studied, consulting the worldwide research trends. Flux chamber method are commonly using in Korea for green house gas emission factors measurement. In recent years, continuous measurement of the microclimate was introduced to measure greenhouse gases from livestock manure storage facilities and the micrometeorology method should be adapted as recommended by Intergovernmental Penal on Climate Change (IPCC) Guideline.