• 제목/요약/키워드: Gas Resistance

검색결과 1,351건 처리시간 0.029초

IC소자용 질화 텅스텐 박막의 면저항 특성 (The Sheet Resistance Properties of Tungsten Nitride Thin films for Intergrated Circuit)

  • 이우선;정용호;김남오;정종상;유병수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.94-97
    • /
    • 1997
  • We investigated the sheet resistance properties of tungsten nitride thin films deposited by RF and DC sputtering system. It deposited at various conditions that determine the sheet resistance. The properties of the sheet resistance of these films were measured under various conditions. Sheet resistance analysed under the flow rate of the argon gas and contents of nitrogen from nitrogen-argon gas mixtures. We found that these sheet resistance were largely depend on the temperature of substrate, gas flow rate and RF power. Very high and low sheet resistance of tungsten films obtained by DC sputtering. As the increase of contents of nitrogen gas obtained from nitrogen-argon gas mixture, tungsten nitride thin films deposited by the reactive DC sputtering and the sheet resistance of these films were increased.

  • PDF

가스보일러용 STS 304의 부식특성에 미치는 용수의 비저항의 영향 (Effect of the Specific Resistance of Water on Corrosion Characteristics of STS 304 for Gas Boiler)

  • 임우조;김환식;윤병두
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.323-328
    • /
    • 2007
  • This paper was studied on the effect of the specific resistance of water on corrosion characteristics of STS 304 for gas boiler. The electrochemical polarization test of STS 304 for gas boiler was carried out. And the polarization resistance, uniform corrosion, corrosion behavior by impressed potential and corrosion sensitivity of STS 304 with specific resistance were considered. The main results are as following: 1) With being low the specific resistance of water, the polarization resistance and corrosion potential of STS 304 decreases, while corrosion current density increases. 2) Under constant impressed potential, the corrosion sensitivity of STS 304 is large with being low the specific resistance due to synergy effect of Cl ion.

$SF_6$ 가스차단기의 아크저항에 관한 연구 (A Study On The Arc Resistance of $SF_6$ Gas Circuit Breaker)

  • 정진교;이우영;김규탁
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1566-1570
    • /
    • 2007
  • [ $SF_6$ ] gas circuit breakers are widely used for short circuit current interruption in EHV(Extra High Voltage) or UHV(Ultra High Voltage) power systems. To develop $SF_6$ gas circuit breakers, the arc resistance value is necessary to compare experimental results to numerical ones. The arc resistance value can be obtained from a breaking test with a $SF_6$ gas circuit breaker. The direct testing or synthetic testing facility is widely used to verify the breaking ability for $SF_6$ gas circuit breakers. We employed the simplified synthetic testing facility to test a $SF_6$ gas circuit breaker prototype. The arc resistance characteristic was measured and calculated under the various experimental conditions. This arc resistance value can be used for verifying the numerical results from arc simulation in a circuit breakers.

스테인레스강의 가스질화 후 내식특성에 미치는 열처리조건의 영향 (Effects of Heat Treatment on Corrosion Resistance Properties of Gas Nitrided Stainless Steels)

  • 김한군;김용현
    • 열처리공학회지
    • /
    • 제22권5호
    • /
    • pp.298-306
    • /
    • 2009
  • Gas nitriding and post oxidation were performed on stainless steels and SACM 645 steel. With increasing gas nitriding time, the increasing rate of nitrided layer was most rapid on SACM 645 steel and the nitriding depth of nitrided layer was most narrow on STS 304 steel among three steels. Corrosion resistance was increased with post oxidation on stainless steels and with increasing time the effect of corrosion resistance was decreased to compare with relatively short gas nitriding time. An improvement effect of corrosion resistance was consisted of predominantly on austenitic stainless steel by post oxidation after gas nitriding among three steels and it was relatively less influenced on martensitic stainless steel.

슈퍼 듀플렉스 용접부에 미치는 보호가스의 영향 (The effect of shielding gases on the characteristics of super duplex weld metal)

  • 홍인표;이철환;김유기;김대순
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.209-211
    • /
    • 2005
  • Super duplex stainless steels have been used for offshore oil and gas piping systems which are subject to corrosion atmosphere, because they have excellent resistance to Stress Corrosion Cracking (SCC) and Pitting corrosion and high strength/weight ratio. Normally, the welding for duplex stainless steels has been peformed using GTAW with Ar shielding gas. However, in case of using Ar as shielding gas, the corrosion resistance at root weld metal will be deteriorated due to loss of nitrogen from weld deposit during welding. It is wellknown that the corrosion resistance of super duplex stainless can be restored by addition of nitrogen as shielding gas. In this study, we made super duplex welding with using several kinds of shielding and purging gases and investigated the relationship between shielding gas and corrosion resistance. Consequently, it was shown that corrosion resistance of weld deposit can be restored by addition of $N_{2}$ as shielding gas.

  • PDF

3%Cr-Mo-V강의 2단 가스질화처리를 통한 표면경화 및 내마모성 연구 (A Study on Wear Resistance and Surface Hardening of 3%Cr-Mo-V Steel by Two-step Gas Nitriding)

  • 정길봉
    • 열처리공학회지
    • /
    • 제22권6호
    • /
    • pp.361-367
    • /
    • 2009
  • The two-step gas nitriding was adopted to increase the depth of surface hardening in 3%Cr-Mo-V steel. The two-step gas nitriding consisted of Step I; $520^{\circ}C{\times}20\;hrs$ and Step II; $550^{\circ}{\times}70\;hrs$. The layer of two-step gas nitriding showed better uniformity and deeper nitriding layer than one-step gas-nitriding layer. The maximum surface hardness showed the value of 850 Hv. The maximum depth of nitrogen permeation showed $750\;{\mu}m$ (350 Hv). X-ray diffraction analysis showed that compound layer was mainly consisted of CrN and $\varepsilon-Fe_3N$ phases. These phases were presumed contributing to surface hardening and wear resistance. However, the corrosion resistance of gas-nitrided Cr-Mo-V steel were not improved in the solution of 1 N HCl and NaOH. Therefore, it is necessary that the continuous study for improvement of corrosion resistance hereafter.

열해석을 이용한 가스 실린더 캐비닛의 내화성능 최적설계 (Optimum Design on Fire Resistance of Gas Cylinder Cabinets using Thermal Analysis)

  • 남민서;김지유;김의수
    • 한국가스학회지
    • /
    • 제26권1호
    • /
    • pp.34-40
    • /
    • 2022
  • 특정 고압가스 등을 사용하기 위해 배관과 안전장치 등이 일체로 구성된 가스 실린더 캐비닛은 화재 발생 시 고온의 열로 인한 급격한 압력상승으로 실린더 폭발 및 파편 비산 등의 위험성을 가지고 있다. 이러한 위험성은 용기 내부에 충전된 가스의 유출을 초래하여 중독, 질식 등의 2차 피해를 발생시킬 가능성이 크므로 내부 용기로 인한 피해를 줄이기 위해서는 가스 실린더 캐비닛의 내화성능 확보가 매우 중요하다. 국외의 경우 가스 실린더 캐비닛이 화염에 노출되는 상황에서 일정 시간동안 내부의 실린더를 보호할 수 있도록 미국 NFPA code, 유럽 EN-14470-2 등에서 가스 실린더 캐비닛 내화시험 기준을 규정하고 있다. 하지만 국내의 경우 내압성능과 기밀성능 기준만 명시되어 있고, 그 대상은 배관계로 한정되어 있으며 국외보다 가스 실린더 캐비닛의 내화성능을 위한 연구 및 규정이 미흡한 실정이다. 이에 본 연구에서는 국내 가스 실린더 캐비닛의 내화성능 기준 확립을 위해 유한요소해석 프로그램인 ANSYS를 이용하여 열해석을 수행함으로써 화재 발생 시 구조, 재질 측면에서의 최적 조건을 도출하고자 한다.

비저항에 따른 가스보일러용 304스테인리스강재의 손상거동에 관한 연구 (Study on the Damage Behavior of 304 Stainless Steel for Gas Boiler with Specific Resistance)

  • 윤병두;임우조;정기철
    • 한국가스학회지
    • /
    • 제9권4호
    • /
    • pp.6-10
    • /
    • 2005
  • 이 논문은 비저항에 따른 가스보일러용 오스테나이트계 스테인리스강(STS304)재의 손상거동에 관해 연구하기 위하여, 비저항에 따른 전기화학적 분극시험을 수행하였다. 그리고 비저항에 따른 가스보일러용 STS304강의 양극분극특성 및 손상거동인 공식양상을 고찰하였다. 비저항이 감소할수록 STS304강의 부동태유지전류밀도는 증가하고 부동태영역은 작아지고 있으며, 관통전위는 낮아지고 있다 또한 비저항이 가장 높은 $74{\Omega}{\cdot}m$중에서 손상거동인 공식양상은 거의 나타나지 않고, 비저항이 낮아질수록 손상거동인 공식양상은 더욱 성장되고, 공식수가 점점 증가하는 경향을 보이고 있다.

  • PDF

Thick-film ammonia gas sensor with high sensitivity and excellent selectivity

  • Lee, Kyuchung;Ryu, Kwang-Ryul;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제2권1호
    • /
    • pp.22-25
    • /
    • 2004
  • A highly sensitive ammonia gas sensor using thick-film technology has been fabricated and examined. The sensing material of the gas sensor is FeOx-$WO_{3}-SnO_{2}$ oxide semiconductor. The sensor exhibits resistance increase upon exposure to low concentration of ammonia gas. The resistance of the sensor is decreased, on the other hand, for exposure to reducing gases such as ethyl alcohol, methane, propane and carbon monoxide. A novel method for detecting ammonia gas quite selectively utilizing a sensor array consisting of an ammonia gas sensor and a compensation element has been proposed and developed. The compensation element is a Pt-doped $WO_{3}-SnO_{2}$gas sensor which shows opposite direction of resistance change in comparison with the ammonia gas sensor upon exposure to ammonia gas. Excellent selectivity has been achieved using the sensor array having two sensing elements.

가스사출시 가스흐름방향의 예측 및 제어 (Control of Gas Direction in Gas Assisted Injection Molding)

  • Soh, Young-Soo
    • 유변학
    • /
    • 제11권2호
    • /
    • pp.153-158
    • /
    • 1999
  • 가스사출시 두개이상의 가스흐름가능방향이 존재 할 때 가스는 선택적인 방향으로 흐르게는데 여기에서는 이 가스흐름 방향을 예측하는 방법을 제시하였다. 지금까지는 가스흐름방향은 가스의 하류에 있는 수지의 저항값, 즉 압력손실필요량을 비교하여 예측되어 왔는데 이방법은 대부분의 경우에 정확한 예측력을 가지고 있었다. 그러나 수지의 저항값 또는 압력손실필요량을 비교하는 방법이 실제에는 경우에따라 맞지 아니하였다. 이 연구에서는 수지속도비교가 압력손실필요량비교 보다 한단계위의 판단기준(criterion)이 되는 것을 설명하고 그예를 들어 증명 하고 있다. 압력손실필요량비교 대신 수지속도비교방법을 쓰면 예외없이 모든 경우 정확하게 가스흐름방향을 예측을 할수 있다.

  • PDF