• Title/Summary/Keyword: Gas Radiation

Search Result 623, Processing Time 0.026 seconds

Characteristics of Low-power Microwave Induced Plasma Emission Spectrum and Detection of $CO_2$ (저출력 마이크로파 유도 플라스마 방출스펙트럼의 특성과 $CO_2$ 분석)

  • Noh, Seung Man;Park, Chang Joon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.4
    • /
    • pp.235-242
    • /
    • 1996
  • A surfatron-type microwave induced plasma (MIP) cavity has been constructed, which can be easily interfaced with a gas chromatograph. Various plasma gases such as He, Ar and N2 were used to generate the MIP and small amounts of CO2 gases were injected through the MIP to obtain characteristic spectrum of each plasma gas and to study feasibility of the MIP as a soft ionization source. Since He and Ar plasmas have high metastable state energy, it was not possible to detect sample gas in molecular state. With N2 plasma, however, a strong emission of molecular ions could be detected owing to its low metastable state energy.

  • PDF

Assessment of occupational radiation exposure of NORM scales residues from oil and gas production

  • EL Hadji Mamadou Fall;Abderrazak Nechaf;Modou Niang;Nadia Rabia;Fatou Ndoye;Ndeye Arame Boye Faye
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1757-1762
    • /
    • 2023
  • Radiological hazards from external exposure of naturally occurring radioactive materials (NORM) scales residues, generated during the extraction process of oil and gas production in southern Algeria, are evaluated. The activity concentrations of 226Ra, 232Th, and 40K were measured using high-purity gamma-ray spectrometry (GeHP). Mean activity concentration of 226Ra, 232Th and 40K, found in scale samples are 4082 ± 41, 1060 ± 38 and 568 ± 36 Bq kg-1, respectively. Radiological hazard parameters, such as radium equivalent (Raeq), external and internal hazard indices (Hex, Hin), and gamma index (Iγ) are also evaluated. All hazard parameter values were greater than the permissible and recommended limits and the average annual effective dose value exceeded the dose constraint (0.3 mSv y-1). However, for occasionally exposed workers, the dose rate of 0.65 ± 0.02 mSv y-1 is lower than recommended limit of 1 mSv y-1 for public.

Bubble Behavior and Radiation for Laser-Induced Collapsing Bubble in Water (물 속에서 레이저에 의하여 생성된 기포의 거동 및 복사현상)

  • Karng, Sarng-Woo;Byun, Ki-Taek;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1282-1287
    • /
    • 2004
  • The bubble behavior and the radiation mechanism from a laser-induced collapsing bubble were investigated theoretically using the Keller-Miksis equation for the bubble wall motion and analytical solutions for the vapor inside bubble. The calculated time dependent bubble radius is in good agreement with observed ones. The half-width of the luminescence pulse at the collapse point, which was calculated under assumption that the light emission mechanism is black body radiation from the vapor bubble agreed well with observed value of several nanoseconds. The gas content inside the vapor bubble was too small to produce the light emission due to bremsstrahlung.

  • PDF

Radiation-Induced Oscillatory Instability in Diffusion Flames (복사 열손실로 인한 확산 화염의 맥동 불안정에 관한 연구)

  • Sohn, Chae Hoon;Kim, Jong Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1185-1191
    • /
    • 1999
  • Radiation-induced oscillatory instability in diffusion flames is numerically investigated with nonlinear dynamics considered. As the simplest flame model, a diffusion flame established in the stagnant mixing layer is employed with optically thin gas-phase radiation and unity Lewis numbers for all species. Attention is focused on the radiation-induced extinction regime, which occurs at large $Damk\ddot{o}hler$ number. Once the steady flame structure is obtained for a prescribed value of the initial $Damk\ddot{o}hler$ number, transient solution of the flame is calculated after a finite amount of the $Damk\ddot{o}hler$-number perturbation is imposed on the steady flame. Transient evolution of the flame exhibits three types of flame-evolution behaviors, namely decaying oscillatory solution, diverging solution to extinction and stable limit-cycle solution. A dynamic extinction boundary is identified for laminar flamelet library.

Convection and Non-Gray Radiation in a Tube with Circumferential Fins and Circular Disks (배플이 있는 튜브 내에서의 대류와 비회복사)

  • Lee, Jae-Yong;Seo, Tae-Beom;Kim, Chong-Bo
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The effect of radiation heat transfer was investigated under various operating conditions in a circular tube with circumferential fins and circular disks. Using a finite volume technique(FVM) for steady laminar flow, the governing equations were derived in order to simulate the flow and temperature fields. In addition, the P-1 approximation and the Weighted Sum of Gray Gas Model(WSGGM) were used for the radiation transport equation(RTE). From the results, radiation heat transfer was significant compared to convection heat transfer. These results will be applied to the design of the heat exchanger for a condensing bolier, which were developed for domestic heating.

  • PDF

Effects of Gas Background Temperature Difference(Emissivity) on OGI(Optical Gas Image) Clarity (가스의 배경 온도 차이(방사율)가 OGI(Optical Gas Image)의 선명도에 미치는 영향)

  • Park, Su-Ri;Han, Sang-Wook;Kim, Byung-Jick;Hong, Cheol-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2017
  • Currently gas safety management in the industrial field has been done by LDAR as contact method or methane leak detector as non-contact method. But LDAR method requires a lot of man-power and methane leak detector have the limitation of methane only. Therefore the Research on the OGI(optical gas image) has big attention by industry. This research was undertaken to see the effect of background temperature difference of gas cloud on the clarity of OGI. The background temperature control panel was constructed to cool down the background temperature. OGI was taken at the various methane gas ejection rate and the designed temperature difference. The experimental results showed that the OGI(when the temperature difference is $-6^{\circ}C$) is more clear thane the OGI(when the temperature difference is zero). To quantify the clarity difference, MATLAB's RGB analysis method was employed. The RGB value of the OGI at ${\Delta}T-6^{\circ}C$ was 20% lower than the OGI at ${\Delta}T0^{\circ}C$. The clarity difference by T difference can be explained by the total radiation law. When the background temperature of the gas is lower than the air temperature, the radiation energy coming into the OGI lens is increasing. As the energy is increasing, the OGI image becomes clear.

Study on Diminution of Pesticide Residues in Citrus Fruits by γ-Irradiation (감마선 조사에 의한 감귤의 잔류농약 저감화 연구)

  • Yang, Hee Sun;Park, Yong Dae;Jin, Chang Hyun;Choi, Dae Seong;Jeong, Il Yun
    • Journal of Radiation Industry
    • /
    • v.3 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • The citrus fruits were irradiated at different doses (25~200 kGy) to remove pesticides such as diuron, dichlorbenil, trifluralin, dimetoate, chlorothalonil, fenitrothion, bromacil, phenthoate and norflurazon, and the rates of degradation were detected by using gas chromatography electron capture detector (GC-ECD). The limit of detection (LOD) was in the range of 0.007~0.105 ppm. The limit of quantification (LOQ) was in the range of 0.024~0.352 ppm, and the recoveries of 9 pesticides were in the range of 71.5~106.5%. The results demonstrated that the ${\gamma}$-irradiation was effective method to remove pesticides such as diuron, dichlorbenil, trifluralin, dimetoate, chlorothalonil, fenitrothion, and norflurazon. However, the bromacil and phenthoate showed lower removal rates in the rate of 40.5 and 54.8%, respectively, at 200 kGy irradiation.

Visualization of Laser-Produced, Xe Gas Plasma in EUV Light Sources for the Lithography (EUV 리소그라피 광원용 레이저 생성 Xe 가스 플라즈마의 가시화)

  • Jin Yun-Sik;Jeong Sun-Sin;Kim Jong-Uk;Kim Chang-Beom;Kim Yong-Ju
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.106-107
    • /
    • 2002
  • Extreme ultraviolet (EUV) radiation of wavelength $\lambda$~10 nm or photon energy hv~100 eV is presently a blank region in the electromagnetic spectrum where applications are concerned. This is because no powerful sources were available until when intense-laser-produced plasmas are available. Both a new laboratory-sized source of EUV radiation and its new applications in lithography of semiconductor devices have been developed. (omitted)

  • PDF

"There's no Place like Home: The Sejong Suite"

  • Rossi, Graziano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.47.3-48
    • /
    • 2020
  • I will present the Sejong Suite, an extensive collection of state-of-the-art high-resolution cosmological hydrodynamical simulations spanning a variety of cosmological and astrophysical parameters, primarily developed for modeling the Lyman-Alpha forest. Adopting a particle-based implementation, we follow the evolution of gas, dark matter (cold and warm), massive neutrinos, and dark radiation, and consider several combinations of box sizes and number of particles. Noticeably, for the first time, we simulate extended mixed scenarios describing the combined effects of warm dark matter, neutrinos, and dark radiation, modeled consistently by taking into account the neutrino mass splitting. Along the way, I will also highlight some new results focused on the matter and flux statistics.

  • PDF

A Study for Optimal filling Condition in Outer Enclosure of Metal Halide Lamp (메탈 할라이드 램프 외관의 최적 봉착조건에 관한 연구)

  • Chee, Chol-Kon;Lee, Sung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.296-299
    • /
    • 1987
  • The purpose of this paper is to increase the lamp efficacy by filling the optimal Nitrogen gas pressure in the outer enclosure of metal halide lamp. This study presents a new model of Langmuir in the outer enclosure of discharge lamp. In this paper, in the first place, the diameter of Langmuir sheath and the total gab loss were calculated. Secondly, the each gas loss was computed if the arbitrary gas pressure is filled, With the calculated data, flash over which affects the lamp efficacy, lamp life and color rendering was considered. In case of the established discharge lamp, the gab pressure has been filled by experience only roughly. The gas loss is converted into the radiation output. Therefore, the lamp efficacy is improved by reducing the gas loss.

  • PDF