• 제목/요약/키워드: Gas Plant

검색결과 1,868건 처리시간 0.023초

마이크로 가스 터빈용 연소기의 연료 노즐의 유량 분배에 관한 수치 해석적 연구 (Numerical Study on Flow Distribution of Fuel Nozzles for a Combustor in a Micro Gas Turbine)

  • 김태훈;도규형;한용식;김명배;최병일
    • 한국연소학회지
    • /
    • 제19권4호
    • /
    • pp.8-13
    • /
    • 2014
  • Flow distribution of fuel nozzles for a combustor in a micro gas turbine is numerically investigated. The fuel supply system for the present study has 12 single nozzles with a diameter of several hundred micrometers. A uniform temperature distribution of a combustor outlet should be achieved for maximizing the lives of the turbine blades and nozzle guide vanes. For this, it is very important to uniformly supply fuel to a combustor. In order to investigate flow distributions of fuel nozzles, numerical models for fuel nozzles are made and solved by a commercial code, ANSYS FLUENT. An effect of a fuel nozzle diameter and fuel flow rates on flow distribution of fuel nozzles is numerically investigated. As a result, non-uniformity is increasing as a diameter of a single fuel nozzle increases. Finally, an appropriate diameter of a single fuel nozzle is suggested.

폐플라스틱의 열분해 유화기술 개발 (Process Development of Pyrolysis Liquefaction for Waste Plastics)

  • 노남선;신대현;박소원;이경환;김광호;전상구;조봉규
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.118-125
    • /
    • 2006
  • The target of this work was the process development of demonstration plant to produce the high quality alternative fuel oil by the pyrolysis of mixed plastic waste. In the first step of research, the bench-scale units of 70 t/y and the pilot plant of 360 t/y had been developed. Main research contents in this step were the process performance test of pilot plant of 360 ton/year and the development of demonstration plant of 3,000 t/y, which was constructed at Korea R & D Company in Kimjae City. The process performance of pilot plant of 360 t/y showed about 80% yield of liquid product, which was obtained by both light gas oil(LGO) and heavy gas oil(HGO), The boiling point range distribution of LO product that was mainly consisting of olefin components in PONA group appeared at between that of commercial gasoline and kerosene. On the other hand, HO product was mainly paraffin and olefin components and also appeared at upper temperature distribution range than commercial diesel. Gas product showed a high fraction of $C_3\;and\;C_4$ product like LPG composition, but also a high fraction of $CO_2$ and CO by probably a little leak of process.

  • PDF

하수처리시설의 에너지 자립화 방안 연구 (Study on Energy Independence Plan for Sewage Treatment Plant)

  • 김영준;이종연;강용태
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.49-55
    • /
    • 2010
  • The objectives of this study are to analyze the energy independence plan and to propose a suitable sewage treatment plant in Korea. The total amount of electricity consumption for public sewage treatment plant was estimated as 1,812 GWh in 2007. It was estimated that total 16 sewage treatment plants with renewable energy systems produced electricity of 15 GWh per year, which could replace 0.8% of total electricity used for sewage treatment. It was found that domestic sewage treatment plants with power generation plants by digestion gas were installed in 7 places and produced electricity of 13 GWh per year. It was also found that the power generation plants by digestion gas were the most cost-effective for sewage treatment plant out of the renewable energy systems based on the benefit-cost analysis.

후처리를 이용한 $CO_2$ 포집이 화력 발전설비 성능에 미치는 영향 해석 (Analysis of the Influence of Post-Combustion $CO_2$ Capture on the Performance of Fossil Power Plants)

  • 탁상현;김동섭;장영수;이대영;김민성
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.545-552
    • /
    • 2010
  • Research and development efforts to reduce $CO_2$ emission are in progress to cope with global warming. $CO_2$ emission from fossil fuel fired power plants is a major greenhouse gas source and the post-combustion $CO_2$ capture is considered as a short or medium term option to reduce $CO_2$ emissions. In this study, the application of the post-combustion $CO_2$ capture system, which is based on chemical absorption and stripping processes, to typical fossil fuel fired power plants was investigated. A coal fired plant and a natural gas fired combined cycle plant were selected. Performance of the MEA-based $CO_2$ capture system combined with power plants was analyzed and overall plant performance including the energy consumption of the $CO_2$ capture process was investigated.

환경에너지 종합타운 조성 타당성에 관한 연구 (Study on Pertinence for Environmental Energy Complex Town Construction)

  • 김영준;이종연;강용태
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.164-171
    • /
    • 2011
  • The objectives of this study are to propose a suitable treatment facility for waste energy recovery after analyzing the waste generation and disposal situation in Jejudo, to establish the plan to install the solar photovoltaics and wind power plant considering the site conditions and finally to establish the environmental energy town plan in conjunction with the existing facilities. The food waste biogas plant is selected as the treatment capacity of 200 ton/day. It is estimated that the biogas plant will produce the electricity of 7,594 MWh per year, which will reduce the greenhouse gas of 4,177 $tCO_2$ per year. The solar photovoltaics and wind power plant will produce the electricity of 13,410 MWh per year, which will reduce the greenhouse gas of 7,375 $tCO_2$ per year. Environmental energy town will give us the reduction of operating cost by centralized treatment of residues and byproducts, and by efficient utilization of produced energy.

암모니아 반응기의 분해 효율 최적화를 통한 암모니아 분해 및 수소 정제 공정 모델 연구 (Optimization of Ammonia Decomposition and Hydrogen Purification Process Focusing on Ammonia Decomposition Rate)

  • 조대명;박종화;유돈상
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.594-600
    • /
    • 2023
  • In this study, a process model and optimization design direction for a hydrogen production plant through ammonia decomposition are presented. If the reactor decomposition rate is designed to approach 100%, the amount of catalyst increases and the devices that make up the entire system also have a large design capacity. However, if the characteristics of the hydrogen regeneration process are reflected in the design of the reactor, it becomes possible to satisfy the total flow rate of fuel gas with the discharged tail gas flow rate. Analyzing the plant process simulation results, it was confirmed that when an appropriate decomposition rate is maintained in the reactor, the phenomenon of excess or shortage of fuel gas disappears. In addition, it became possible to reduce the amount of catalyst required and design the optimized capacity of the relevant processes.

排氣가스로 만든 人工酸性雨에 의한 植物의 形態的 症狀 (Plant morphological symptom caused by simulated acidic rain made by fuel gases)

  • Chang, Nam-Kee;Yun-Sang Lee;Soo-Jin Yi
    • The Korean Journal of Ecology
    • /
    • 제16권1호
    • /
    • pp.17-26
    • /
    • 1993
  • We investigated the ph change of water caused by several fuel gases regarded as the main cause of the air pollution, To find out the main cause of increase of the acidity of the rain. We measured it while injrcting each fuel gas directiy to the distilled water. It was observed that bunker-c oil gas and anthracite coal gas were the main cause to make the ph of the solution lowest. We examined the effects of simulated acidic water solutions on several plant species. Simulated acidic rain made by bunker-c oil gas has significant symptom on the saxifraga stolonifera and commelina communis, while no injury was observed on plants exposed to simulated rainfall made by anthracite coal gas.

  • PDF

발전용 가스터빈에서 발생하는 연소진동 특성 및 이상연소진동의 저감 (Characterization of Combustion Oscillation and Reduction of Abnormal Oscillation in a Power Generation Gas Turbine)

  • 서석빈;안달홍;정재화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1682-1685
    • /
    • 2004
  • Gas Turbine combustors for power plant can be reduced NOx emissions using lean premixed combustion technology. But the combustors are likely to occur combustion oscillations which damage operation reliability and mechanical life of the gas turbines. In this paper, characterizations of oscillation in a gas turbine combustor for power plant are presented. Combustion dynamics occur $1{\sim}1.5$ psi in amplitude with low frequency less than 140Hz during normal operation. An abnormal high level dynamics, 2.0 psi amplitude occur at 125 Hz frequency. Abnormal combustion oscillation is reduced by modulation of fuel supply valve control schedule.

  • PDF

Fe-EDTA계 액상촉매 산화법에 의한 분뇨처리장 악취제거에 관한 연구 (Studies on the Deodorization in the Nightsoil Treatment Plant with liquid Phase Catalytic Oxidation Method by Utilization of Fe-EDTA)

  • 이인화
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.105.1-113
    • /
    • 1992
  • The present study was performed to develop the removal system of the offensive gases, including hydrogen sulfide of acid gas, ammonia or amice of base gas, from the nightsoil treatment plant. In order to remove the offensive gases, the Fe-EDTA system liquid phase catalytic oxidation method with the bubble lift column reactor was employed. From the results obtained, it was confirmed that the offensive gases can be deodorized simultaneously and also hydrogen sulfide of acid gas, ammonia of base gas completely removed at pH 6.45. In addition, as input gases feed rate the efficiency of acid gas did not change but the efficiency of base gases decreased to approximately 90 % at pH 6, 0. From the result of particle size analyzer, it was found that the particle sizes including sulfur and other impurites grew up to $21{\mu}m$ over 72hour reaction time.

  • PDF

가스터빈 복합 열병합 발전의 최적 운전조건에 관한 연구 (A Study for the Optimal Operating Conditions of the Gas Turbine Based Combined Cycle Cogeneration Power Plant)

  • 조영빈;손정락;노승탁
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1582-1590
    • /
    • 2004
  • The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine.