• Title/Summary/Keyword: Gas Hazard

Search Result 262, Processing Time 0.034 seconds

Health Risk Assessment and Analysis on the Volatile Organic Compounds in Some Workplace (모작업장에서 휘발성 유기오염물질의 분석과 근로자들의 건강위해성 평가)

  • Lee, Hyo-Min;Kim, Myung-Soo;Choi, Shi-Nai;Yoon, Eun-Kyung;Park, Jong-Sei
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.530-539
    • /
    • 1997
  • This study was conducted to assess the health risk on the volatile organic compounds such as toluene, xylene, and styrene in painting workplace. It was monitored through personal air sampling during working time in selected 5 workplaces and analysed using gas chromatography. For the settlement of exposure situation, there were regarded working conditions such as working hours, yearly working days, and working years. Also, Monte-Carlo simulation was used for the induction of hazard index using toxicity value from IRIS(Integrated risk information system) database. The results of risk assessment were summarized as follows. 1. The air concentration of toluene was $7.096{\pm}15,644ppm,\;2.586{\pm}4.275ppm\;for\;xylene,\;1.914{\pm}5.320ppm$ for styrene in blast painting workplaces. The level of toluene was different significantly compared with the level of xylene and styrene. 2. Computated chronic daily intake values of 95th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 9.616, 3.567, 2.782 mg/kg/day, respectively. 3. Computated hazard index values of 75th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 3.5, 1.0 and 1.6, respectively. Adverse health effects on the toluene, xylene and styrene would be expected by working exposure in selected 5 workplaces since the hazard indices of three compounds were exceeded 1 in the surroundings of 75th percentile though having the low emerged frequency.

  • PDF

Dynamic Behavior of Buried Pipelines Constructed by Domestic and USA Specifications (국내 및 미국 시방서에 따라 시공된 지중매설관의 동적거동)

  • Jeon, Sang-Soo;Kim, Jae-Min
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Lifeline Damages induced by earthquake loading brings not only a structure damage but the communication problems by the interruption of various energy utilities such as electric power, gas, and water resources. Earthquake loss estimation systems in USA and Japan, called as HAZUS (Hazard in US) and HERAS (Hazards Estimation and Restoration Aid System), respectively, have been established for the purpose of efficient responding to the earthquake hazard. Sufficient damage records are required to establish these systems. However, there are insufficient data set of damage records obtained from previous earthquakes in Korea. In this study, according to the construction specifications of the pipelines in both Korea and USA, the behavior of both ductile and brittle pipelines embedded in dense sand overlying various soils, such as clay, sand, and gravel were examined with respect to the pipeline characteristics under various earthquake loadings. The applicability of pipeline damage prediction used in HAZUS program to Korea has been investigated.

Qualitative Hazard Analysis for a Batch Radical Reaction Process using HAZOP Method (HAZOP 기법을 이용한 회분식 라디칼 반응 공정에 대한 정성적 위험성 평가 방법 연구)

  • Park, KyungMin;Lee, DongKyu;Lee, JoonMan;Ahn, WonSool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.385-393
    • /
    • 2019
  • Potential fire, explosion and safety hazards exist in medium- or small-scale chemical plants using radical batch reaction processes due to the various conditions of materials, works or products. To minimize the potential damage, a study was conducted on qualitative hazard analysis using the HAZOP technique, which is a typical method for a qualitative risk assessment and analysis of the potential risks encountered in these chemical plants. For this purpose, a domestic chemical plant, which produces the acrylic resin by a radical batch reaction process, was selected and a risk assessment and analysis according to the procedure of HAZOP method was performed for the process. As the result of the study, to prevent the hazard, the input of inert gas and the installation of a pressure gauge were indispensable. In addition, the initiator and monomer should also be separated, and inhibiting substances and equipment are also necessary to prevent a runaway reaction.

A Study on the Hazard of Converted Gas for Surface Heating Treatment (표면열처리용 변성가스의 위험성에 관한 연구)

  • Choi Jae-Wook;Min Wong-Chul;Lim Woo-Sub;Lee Byoung-Chul;Kim Dong-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.9-14
    • /
    • 2005
  • To estimate the explosion characteristics of converted gas, the study was examined into effects of altering oxygen concentration and adding hydrogen. From the result of the experiment, as the concentration of converted gas and hydrogen were increased at $21\%$ oxygen concentration, the lower explosion limit was low. Minimum explosion oxygen concentration was $6\%$. Maximum explosion pressure of converted gas was $4.61 kg_f/cm^2$, now Maximum explosion pressure rising velocity was $130.75 kg_f/cm^2/s$ at converted gas concentration $40\%$. Also, minimum ignition energy was 0.13 mJ at converted gas concentration $50\%$.

  • PDF

Determination of Optimum Investment level for Safely Management by Process Risk Assessment at Gas Governor Station (가스공급기지에서 공정 위험성 평가에 의한 최적 안전관리 투자수준 결정)

  • Kim Tae-Ok;Jang Seo-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.1-6
    • /
    • 2003
  • This study has suggested a decision method which determine optimum investment level for safety management by process risk assessment at gas governor station. Hazard and operability study(HAZOP), fault tree analysis(FTA) and consequence analysis(CA) were carried out and potential accident cost and benefit for safety management were estimated. As a result, we could be found the trend of safety cost and benefit by the nonlinear regression method and could be determined the optimum investment level for safety management from analysis of safety management cost and potential accident cost.

  • PDF

Standards of Distance between Gas Pipeline and Tower Ground (가스배관과 철탑접지의 이격거리 관련 기준)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.18-22
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we investigated the arcing phenomena through soil between a power line tower and a pipeline and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

A Case Study on the Risk Assessment for Offshore Plant Solid Desiccant Dehydration Package by using HAZOP (HAZOP을 통한 해양플랜트 흡착식 탈수공정 패키지의 위험성평가 및 안전도 향상 방안)

  • Noh, Hyonjeong;Park, SangHyun;Cho, Su-gil;Kang, Kwangu;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.569-581
    • /
    • 2020
  • Since the dehydration packages of offshore plant deal directly with oil & gas, there is a great risk of fire and explosion during operation. Therefore, this study performed risk assessment through HAZard & OPerability (HAZOP) for solid desiccant dehydration package that can remove water component of natural gas in offshore floating liquefied natural gas (LNG) production facilities below 0.1 ppmv. The risk matrix was determined by dividing the likelihood and the severity into five levels separately by asset, life, environment and reputation. The piping & instrumentation diagram (P&ID) of the dehydration package was divided into 9 nodes. Total 22 deviations were assessed in consideration of the adsorption and desorption conversion cycle. A risk assessment based on deviations revealed 14 major hazards. Three representative types of hazards were open/close failure of the control valve, control failure of the heater, and abnormal operation of the regeneration gas cooler. Finally, we proposed the installation of additional safety devices to improve safety against these major hazards, such as safety instrumented functions, alarms, etc.

The Estimation of earthquake-resistance for gas utility using Equivalent Static Analysis (가스시설물의 등가정적 해석에 의한 내진성능 평가)

  • Koh J. P.;Hong S. K.;Kim J. H.;Jeong S. Y.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.23-32
    • /
    • 2002
  • The purpose of the present study is to analyze the response of Gas Utility subjected to Earthquake and to discuss the failure prediction of Kogas Storage Tank. Initially here, characteristics of Earthquake are reviewed and then earthquake-resistance Design is investigated based on previous earthquake hazard cases. Next, considering the distribution of the transverse permanent ground displacement and equivalent spring constant effect, formulae obtained by a beam theory are established to analyze PeungTak Center Control Room. This analysis was performed without consideration of axial effects. So the finite element analysis was used in order to consider the axial stiffness of Structure.

  • PDF

A Study on the Explosion Phenomenon and Flame Propagation of LP Gas (LP가스의 폭발 현상 및 화염전파에 관한 연구)

  • Choi, Jae-Wook;Lee, Dong-Hoon;Kim, Tae-Gn;Min, Wong-Chul;Lim, Woo-Sub;Choi, Byoung-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.65-70
    • /
    • 2007
  • The explosion phenomenon and hazard estimate of LP gas, the study was examined into variation of oxygen concentration and LP gas concentration. As the result of experiment, the lower explosive limit was decreased as the increased at concentration of LP gas and 21% of oxygen concentration. Minimum oxygen concentration was 14.5%. 12.0%, 11.5% at 1.0, 1.5 and 2.0 bar respectively. And maximum explosion pressure was increased for $6.46kg/cm^2,\;9.41kg/cm^2\;and\;13.49kg/cm^2$ according to increased of pressure. The speed of flame propagation was increased as the higher with initial pressure of LP gas.

  • PDF

Risk Assessment for High Capacity Multiport Hydrogen Refueling Station (대용량 멀티포트 동시 충전 기반 수소충전소 안전성 평가 연구)

  • CHOONGHEE JOE;SEUNGKYU KANG;BUSEUNG KIM;KYUNGSIK LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.505-513
    • /
    • 2023
  • Hydrogen infrastructure is expanding. High-capacity hydrogen refueling stations offer advantages because they can refuel a variety of light and heavy-duty vehicles, and multi-port refueling technology is developing to reduce charging time for heavy-duty vehicles. In this study, we suggest directions to lower the risk by analyzing the risk factors for each process involved in the installation of a high-capacity multi-port hydrogen refueling station in Changwon city. We conducted both qualitative and quantitative risk assessments of the equipment to evaluate the station. A hazard and operability study was performed for qualitative risk assessment, and PHAST/SAFETI were used for quantitative risk assessment. Quantitative risk assessment was used to calculate the consequence analysis of the facility to ensure secure design prior to station development and to predict individual and societal risks in various scenarios. As a result, the station's risk level was determined to be as low as reasonably practicable.