• Title/Summary/Keyword: Gas Emission Facilities

Search Result 123, Processing Time 0.025 seconds

Property Analysis of Municipal Solid Waste and Estimation of CO2 Emissions from Waste Incinerators (생활폐기물 특성 분석 및 소각시설의 CO2 배출량 평가)

  • Kim, Byung-Soon;Kim, Shin-Do;Kim, Chang-Hwan;Lee, Tae-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.657-665
    • /
    • 2010
  • Carbon dioxide ($CO_2$) is known to be a major greenhouse gas partially emitted from waste combustion facilities. According to the greenhouse gas emission inventory in Korea, the quantity of the gas emitted from waste sector in 2005 represents approximately 2.5 percent of all domestic greenhouse gas emission. Currently, the emission rate of greenhouse gas from the waste sector is relatively constant partly because of both the reduced waste disposal in landfills and the increased amounts of waste materials for recycling. However, the greenhouse gas emission rate in waste sectors is anticipated to continually increase, mainly due to increased incineration of solid waste. The objective of this study was to analyze the property of Municipal Solid Waste (MSW) and estimate $CO_2$ emissions from domestic MSW incineration facilities. The $CO_2$ emission rates obtained from the facilities were surveyed, along with other two methods, including Tier 2a based on 2006 IPCC Guideline default emission factor and Tier 3 based on facility specific value. The $CO_2$ emission rates were calculated by using $CO_2$ concentrations and gas flows measured from the stacks. Other parameters such as waste composition, dry matter content, carbon content, oxidation coefficient of waste were included for the calculation. The $CO_2$ average emission rate by the Tier 2a was 34,545 ton/y, while Tier 3 was 31,066 ton/y. Based on this study, we conclude that Tier 2a was overestimated by 11.2 percent for the $CO_2$ emission observed by Tier 3. Further study is still needed to determine accurate $CO_2$ emission rates from municipal solid waste incineration facilities and other various combustion facilities by obtaining country-specific emission factor, rather than relying on IPCC default emission factor.

Development of Greenhouse Gas Emission Factors from Sewage Sludge Incinerator (하수슬러지 소각장의 온실가스 배출계수 개발)

  • Kim, Seungjin;Kang, Seongmin;Kang, Soyoung;Lee, Jeongwoo;Sa, Jae-Hwan;Park, Seong-Jin;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.5 no.3
    • /
    • pp.209-218
    • /
    • 2014
  • In this study, the researchers have developed the greenhouse gas emission coefficients targeted at sewage sludge incineration plants that treat sewage sludge by incineration. Among the gases emitted from the sewage sludge incineration plants, the greenhouse gases showed concentrations of 6.84% for $CO_2$, 4.51 ppm for $CH_4$, and 86.34 ppm for $N_2O$; calculated into greenhouse gas emission coefficients, these gave $276.06kg\;CO_2/ton$, $0.0066kg\;CH_4/ton$, and $0.35kg\;N_2O/ton$. As the result of calculating the greenhouse gas emission quantity in sewage sludge incineration plants using the greenhouse gas emission coefficients, the gross greenhouse gas emission was $84.63ton\;CO_2\;eq./day$, and the net emission was $23.90ton\;CO_2\;eq./day$; this was $37.52ton\;CO_2\;eq./day$ less than the net greenhouse gas emission that was calculated using the standard values of IPCC, which was $61.42ton\;CO_2\;eq./day$. This difference is probably because unlike the standard values of IPCC, the greenhouse gas emission coefficients of this study reflected the special properties of subject facilities. Thus, it is thought that emission coefficient research on the facilities that deviated from the standard values of IPCC should continue to achieve the development of national greenhouse gas coefficient that reflects the special properties of Korea.

A Study on Characteristics of Pollutants from LNG Facilities (천연가스 사용설비 오염물질 배출특성 연구)

  • Lee, J.S.;Lee, H.C.;You, H.S.;Han, J.O.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.223-226
    • /
    • 2004
  • The thesis examined the charactcri:stlC of pollutants exhausted from LNG facilities. So, combustion gas and concentration of greenhouse gas exhausted from gas boiler for home use, furnace facilities, electric power facilities, boiler for industrial use and boiler for heating fueled LNG is measured. And the exhaust factor of pollutants is produced by classify of pollutants in detail. And this exhaust factor is compared and investigated with data of a foreign nations.

  • PDF

Interrelations between Greenhouse Gas (GHG) Emission and Total Floor Area of Buildings -With the Case Study of Public Facilities in Ontario, Canada-

  • Son, Juntae;Chang, Seongju
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.95-99
    • /
    • 2017
  • Recently, it is becoming increasingly difficult to ignore carbon emission implication of building operations due to the significant rate of energy usage in buildings. In the building sector, our normal expectation implies that large building floor area induces more greenhouse gas (GHG) emission. In this research, the correlation between building total floor areas and GHG emission was explored by simple linear regression and analyzing the yielded residuals for confirming this seemingly obvious conjecture. By looking at the generated regression lines drawn based on the data sets representing public facilities in Ontario, Canada, we were able to confirm that carbon emission rate shows a proportional increase or decrease depending on the total floor area of buildings as has been implied as a conjecture. Some buildings were found to emit significantly large and small amount of GHG, and we addressed potential reasons why those buildings show the deviation from the confirmed proportional interrelation between a building's total floor area and the amount of GHG emission.

Availability Analysis on Detection of Small Scale Gas Emission Facilities using Drone Imagery (드론영상을 이용한 소규모 가스 배출시설 탐지 가능성 분석)

  • Shin, Jung-Il;Kim, Ik-Jae;Hwang, Dong-Hyun;Lee, Jong-Min;Lim, Seong-Ha
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.1
    • /
    • pp.213-223
    • /
    • 2017
  • Recently, the air quality of South Korea has deteriorated and public interest has been increasing. Various observation means are used for the monitoring of the atmospheric environment, but it relies on the experience and judgment of the observer in the absence of spatial information on the emission facilities. The purpose of this study was to determine the availability of using drones for monitoring air pollutant emission facilities. A texture transformation method was applied to the drone ortho image to detect the small gas emission facility and the slope data calculated by the digital surface model (DSM) was used to reduce the false alarm ratio. As a result, it shows the possibility of using drones in the detection of small gas emission facilities by showing about 80% of positive detection ratio and 40% of false alarm ratio. In the future, various researches are required to the improve positive detection ratio and the reduction of the false alarm ratio. Based on these results, it is necessary to construct a database including 3D spatial information of air pollutant emission facilities.

A Study on Environment-Friendly Characteristics of campus buildings for creating a green campus (그린캠퍼스 조성을 위한 대학건물의 친환경적 특성에 관한 연구)

  • Jeong, Sook-In;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.221-228
    • /
    • 2009
  • Recently severity of ecological adaptation and climatic change due to global warming grows larger. According to the fourth report of IPCC in 2007, emission quantity of the earth greenhouse gas(GHGs) generated by activity of mankind increased with 80% since 1970. And it is forecasted that worldwide greenhouse gas will be increased with 25~90%(corresponding to $CO_2$) between 2000 and 2030. This increment of greenhouse gas($CO_2$) is expected to raise average temperature of the earth with the maximum $6.4^{\circ}C$, and sea surface with 59cm in 2090. Like this, destruction of environment by greenhouse gas is regarded as universal problem threatening the existence, not only the problem of one nation. Consequently, systematic correspondence to the global warming at the aspect of energy consumption is also needed in Korea. From the analysis result of 'Statistics of Energy Consumption' published by Green Korea in 2007, energy consumption increment of domestic universities was higher as many as 3.7 times than 22.5% of the whole energy consumption increment in our country. This says to be the direct example which shows that universities are huge sources of greenhouse gas emission. New constructing and enlarging buildings of each universities within campus are the most major reason for such a large increment of energy consumption in universities. The opinion that the possibility of causing energy waste and efficiency reduction is raised by increased buildings of universities has been propounded. That is, universities should make concrete goal and the plan for reducing emission of green house gas against climatic change, and should practice. Accordingly, there is the meaning that 2 aspects of environment-friendly design characteristics, that is application of energy utilizing technology, material usage of energy efficiency-side and environment-side, and introduction of natural element in the environmental aspect, were analyzed for facilities of university campus designed in environment-friendly point of view from initial stage of plan, and direction of environment-friendly design of university facilities in the future was groped in order to grasp environment-friendly design tendency of internal and external University facilities based on this analysis of this paper.

Emission Reduction of Air Pollutants Produced from Chemical Plants

  • Lee, Byeong-Kyu;Cho, Sung-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.29-38
    • /
    • 1999
  • This study identified emission sources and emissions of air pollutants such as volatile organic compounds (VOCs), solvents, and acid gases produced from chemical plants. We collected air samples from various processes, reactors and facilities using VOC detectors and workers' experience. We identified chemical structures and emission concentrations of air pollutants. We analyzed total emissions of air pollutants emitted from the chemical plants. Also, we developed some emission reduction technologies based on chemical types and emission situations of the identified air pollutants. For reduction of air emissions of acid gases, we employed a method improving solubility of pollutants by reducing scrubber operation temperature, increasing surface area for effective contact of gas and liquid, and modifying or changing chemicals used in the acid scrubbers. In order to reduce air emissions of both amines and acid gases, which have had different emission sources each other but treated by one scrubber, we first could separate gas components. And then different control techniques based on components of pollutants were applied to the emission sources. That is, we first applied condensation and then acid scrubbing method using H2SO4 solution for amine treatment. However, we only used an acid scrubbing method using H2O and NaOH solution for acid gas treatment. In order to reduce air emissions of solvents such as dimethylformamide and toluene, we applied condensation and activated carbon adsorption. In order to reduce air emissions of mixture gases containing acid gases and slovents, which could not be separated in the processes, we employed a combination of various air pollution control devices. That is, the mixture gases were passed into the first condenser, the acid scrubber, the second condenser, and the activated carbon adsorption tower in sequence. In addition, for improvement of condensation efficiency of VOCs, we changed the type of the condensers attached in the reactors as a control device modification. Finally, we could successfully reduce air emissions of pollutants produced from various chenmical processes or facilities by use of proper control methods according to the types and specific emission situations of pollutants.

  • PDF

CO2 Emission Analysis from Horticultural Facilities & Agricultural Machinery for Spread of New and Renewable Energy in Rural-type Green Village (농촌형 녹색마을에 신재생에너지 보급을 위한 시설재배 및 농업기계의 CO2 배출량 분석)

  • Kim, J.G.;Ryou, Y.S.;Kang, Y.K.;Kim, Y.H.;Jang, J.K.;Kim, H.T.;Seo, K.W.;Lee, S.K.;Cho, H.J.;Kang, J.W.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.1
    • /
    • pp.86-92
    • /
    • 2011
  • In order to reduce dependence on the fossil fuels and $CO_2$ gas emission in farming activities, the government has pushed ahead with making the self-sufficiency of farming energy up 40% level in green villages. The objectives of this study are to survey the energy consumption of horticultural facilities or agricultural machineries, and to analyze the reduced $CO_2$ gas emission level from fossil fuel to bio-diesel fuel. For the implement of this study, it is necessary to analyze the energy consumption level in the various sector of farming activities, and available renewable energy sources should be selected. Annual total $CO_2$ gas emission in the tillage farming sector was analyzed as $5,667,258\;t-CO_2$ and that in the horticultural facilities occupied $4,932,607\;t-CO_2$, while the $CO_2$ gas emission level of diesel fuel was $3,105,707\;t-CO_2$, and that of the heavy oil showed $1,370,578\;t-CO_2$. The average $CO_2$ gas emission level of horticultural facilities in the country was analyzed as $29,418\;t-CO_2/ha$. Among the total energy consumption of agricultural machineries, tractor used 284,763kL, power tiller spent 221,314 kL, grain drier consumed 145,524kL and combine tractor expend 72,537kL. From the comparison of $CO_2$ gas emission level between fossil fuel and bio-diesel fuel for the horticultural facilities or agricultural machinery in G-City, Jeonbuk Province, the $CO_2$ gas emission level can be reduced by 7% through replacing the fuel from fossil to biodiesel.

SRF Combustion Pollutants' Impact on Domestic Emissions Assessments (SRF 사용 시 발생되는 대기오염물질 (PM, NOx)의 국가배출량 기여도 평가)

  • Kim, Sang-Kyun;Jang, Kee-Won;Kim, Jong-Hyeon;Yoo, Chul;Hong, Ji-Hyung;Kim, Hyung-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.656-665
    • /
    • 2012
  • Recently, yearly production of SRF (Solid Recovered Fuel) as an alternative fuel has been rapidly increasing because of the limited waste disposal, rise in oil prices and reduction of greenhouse gas emission. However, SRF using facilities are excluded from the National Air Pollutant Emission Estimation because SRF using facilities are not yet included among the SCC (Source Classification Code). The purpose of this research was to estimate the emission and emission factor of SRF using facilities' PM and $NO_x$, in order to investigate whether or not they are included in the National Air Pollutant Emission Estimation. The emission factors of SRF using facilities' PM and $NO_x$ are calculated as 0.216 kg/ton, and 3.970 kg/ton, and the emission was estimated based on the yearly total SRF usage of 2011. The results above was 18.7% for PM and 12.8% for $NO_x$ emissions from combustion facility (SCC2) in manufacturing industry combustion (SCC1) of CAPSS. If CAPSS estimate the emission by adding SCC on unlisted SRF in case of Boiler (SCC3) fuel, both PM and $NO_x$'s emissions would increase by 15.8% and 11.3% compare to the emissions for the existing combustion facility. As a result, emissions caused by SRF should be considered when calculating the National Air Pollutant Emission Estimation. In addition, further researches to develop emission factor and improve subdivided SCC should be done in the future, for the accurate and reliable estimation of National Emission.

Effects of Hydrogen Sulfide and Siloxane on Landfill Gas Utility Facilities

  • Nam, Sang-Chul;Hur, Kwang-Beom;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.159-164
    • /
    • 2011
  • This study examined the emission characteristics of impure gas-like hydrogen sulfide and siloxane contained in landfill gas (LFG) and investigated the effect of impure gas on LFG utility facilities. As a result of an LFG component analysis from eight landfills in the same environment, hydrogen sulfide averaged 436 ppmv (22-1,211 ppmv), and the concentration of total siloxane averaged 7.95 mg/$m^3$ (1.85-21.18 mg/$m^3$). In case of siloxane concentration by component, the ratio of D4 (average 3.79 mg/$m^3$) and D5 (average 2.64 mg/$m^3$) indicated the highest level. Different kinds of scales were found on the gas air heater (GAH) and inside the boiler. The major component of scale from the GAH was $Fe_2O_3$ of 38.5%, and it was caused by hydrogen sulfide. Other scale was found on the bottom and the wall of the boiler and the scale was silicon dioxide of 92.8% and 98.9%. The silicon dioxide scale was caused by combustion of siloxane. As a result of a scanning electron microscopy analysis, the structure of the silicon dioxide scale from the boiler was an immediate filamentous type. Consequently, as silicon dioxide scale is bulky, such bad effects were worsening, as an interruption in heat conduction, increase in fuel consumption, damage to the boiler by overheating, and clogged emission pipeline could occur in LFG utility facilities.