Browse > Article
http://dx.doi.org/10.5572/KOSAE.2012.28.6.656

SRF Combustion Pollutants' Impact on Domestic Emissions Assessments  

Kim, Sang-Kyun (Air Pollution Engineering Division, National Institute of Environmental Research)
Jang, Kee-Won (Air Pollution Engineering Division, National Institute of Environmental Research)
Kim, Jong-Hyeon (Air Pollution Engineering Division, National Institute of Environmental Research)
Yoo, Chul (Air Pollution Engineering Division, National Institute of Environmental Research)
Hong, Ji-Hyung (Air Pollution Engineering Division, National Institute of Environmental Research)
Kim, Hyung-Chun (Air Pollution Engineering Division, National Institute of Environmental Research)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.28, no.6, 2012 , pp. 656-665 More about this Journal
Abstract
Recently, yearly production of SRF (Solid Recovered Fuel) as an alternative fuel has been rapidly increasing because of the limited waste disposal, rise in oil prices and reduction of greenhouse gas emission. However, SRF using facilities are excluded from the National Air Pollutant Emission Estimation because SRF using facilities are not yet included among the SCC (Source Classification Code). The purpose of this research was to estimate the emission and emission factor of SRF using facilities' PM and $NO_x$, in order to investigate whether or not they are included in the National Air Pollutant Emission Estimation. The emission factors of SRF using facilities' PM and $NO_x$ are calculated as 0.216 kg/ton, and 3.970 kg/ton, and the emission was estimated based on the yearly total SRF usage of 2011. The results above was 18.7% for PM and 12.8% for $NO_x$ emissions from combustion facility (SCC2) in manufacturing industry combustion (SCC1) of CAPSS. If CAPSS estimate the emission by adding SCC on unlisted SRF in case of Boiler (SCC3) fuel, both PM and $NO_x$'s emissions would increase by 15.8% and 11.3% compare to the emissions for the existing combustion facility. As a result, emissions caused by SRF should be considered when calculating the National Air Pollutant Emission Estimation. In addition, further researches to develop emission factor and improve subdivided SCC should be done in the future, for the accurate and reliable estimation of National Emission.
Keywords
SRF; CAPSS; SCC; Emission factor; Emission; PM; $NO_x$;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Australian Greenhouse office (2001) Technical guidelines (Generator efficiency standards version 1.2, 14-33.
2 European Environment Agency (EEA) (2006) EMEP/CORINAIR Emission Inventory Guidebook 2006. Technical report No 11/2006, Copenhagen K, Denmark.
3 Jang, K.W., H.C. Kim, Y.M. Lee, D.J. Song, N. Jung, S.K. Kim, J.H. Hong, S.J. Lee, and J.S. Han (2011) Estimating PM Emission Factor from Coal-Fired Power Plants in Korea, Journal of Korea Society for Atmospheric Environment, 27(5), 485-493.   과학기술학회마을   DOI   ScienceOn
4 Jang, K.W., J.H. Lee, S.W. Jung, K.H. Kang, and J.H. Hong (2009) A Study on the Comparison of Emission Factor Method and CEMS (Continuous Emission Monitoring System), Journal of Korean Society for Atmospheric Environment, 25(5), 410-419.   과학기술학회마을   DOI   ScienceOn
5 Jeon, E.C., S.H. Myeong, J.H. Jeong, S.H. Lee, J.W. Sa, G.W. Roh, K.H. Kim, and W.S. Bae (2007) Development of Emission Factors for Greenhouse Gas ($CO_{2}$) from Anthracite Fired Power Plants in Korea, Journal of Korea Society for Atmospheric Environment, 23(4), 440-448.   과학기술학회마을   DOI   ScienceOn
6 Kim, D.G., K.H. Kang, K.W. Jang, J.H. Lee, S.W. Jung, J.H. Hong, and D.I. Jung (2008) Trend Analysis of Air Pollutants Emission in Korea (2001-2006), Proceeding of the 47th Meeting of Korean Society for Atmospheric Environment, 137-138.
7 Lee, D.G., Y.M. Lee, K.W. Jang, C. YOO, K.H. Kang, J.H. Lee, S.W. Jung, J.M. Park, S.B. Lee, J.S. Han, J.H. Hong, and S.J. Lee (2011) Korean National Emissions Inventory System and 2007 Air Pollutant Emissions, Asian Journal of Atmospheric Environment, 5-4, 278-291.   과학기술학회마을   DOI   ScienceOn
8 Ministry of Environment (2008) "Comprehensive measures for waste".
9 Ministry of Environment (2009) Enforcement Rule of the act on the promotion of saving and recycling of resources, Article 20-(3)-2.
10 National Institute of Environmental Research (NIER) (2010) A Study of Emission Characteristics of Air Pollutants from Facilities using Reclaiming Fuel, No. 2010-76-1251.
11 National Institute of Environmental Research (NIER) (2010) National Air Pollutant Emission Calculation Method Manual.
12 National Institute of Environmental Research (NIER) (2011a) A Study of Air Pollutants Reduction Plan for Waste Solid Fuel Fired Facilities, No. 2011-1437.
13 National Institute of Environmental Research (NIER) (2011b) National Air Pollutants Emission 2009, No GP2011- 1310.
14 US Environmental Protection Agency, AP-42 5th ed., "Solid Waste Disposal".
15 US Environmental Protection Agency (2000) Carbon dioxide emissions from the generation of electric power in the united states.
16 US Environmental Protection Agency (1997) Procedures for preparing emission factor documents, EPA 454/R- 95-015 REVISED.
17 Van der lans, R.P., P. Glarborg, and K. Dam-Johansen (1997) Influence of process parameters on nitrogen oxide formation in pulverized coal burners, Energy Combustion, 23(1997), 349-377.   DOI   ScienceOn