Effect of Working Gas Pressure on Misfirng of ac PDP at High Ambient Temperature

  • Ryu, Jae-Hwa;Choi, Joon-Young;Kim, Dong-Hyun;Kim, Joong-Kyun;Kim, Young-Kee;Lee, Ho-Jun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.4 no.4
    • /
    • pp.25-32
    • /
    • 2003
  • One of the important problems in ac PDP in recent years is the misfiring of ac PDP at high ambient temperatures which consequently degrades the image quality of the ac PDP. This may be due to the change of working gas pressure and/or MgO surface characteristics at high ambient temperatures. This paper deals with the effect of working gas pressure on the misfiring of ac PDP at high ambient temperature. From this study, we found that the main cause of the misfiring at high ambient temperature is the increase in discharge firing voltage induced by increased working gas pressure

Thermodynamic Analysis of High Pressure Multi-stage Reciprocating Compressors with Inter-coolers (중간 냉각기가 있는 고압 다단 왕복동식 압축기에 관한 열역학적 해석)

  • Lee, Euk-Soo;Kim, Myung-Hun;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.9
    • /
    • pp.1238-1247
    • /
    • 2003
  • Simplified thermodynamic analysis of high pressure 4-stage reciprocating compressors with 4 inter-coolers has been investigated to predict a behavior of a compressor system for NGV(natural gas vehicles). A computer program has been developed to predict and estimate the performance of high pressure 4-stage reciprocating compressor system. Thermodynamic properties of compressed natural gas(CNG) were calculated by ideal gas theory and compression cycle was assumed as reversible adiabatic compression and expansion processes, and isobaric intake and discharge processes. Comparison between results predicted by calculation model and measured by experimental tests is presented.

Evaluation of Component Performance of a Commercial Micro Gas Turbine (상용 마이크로 가스터빈의 구성부 성능분석)

  • Lee, J.J.;Yun, J.E.;Kim, T.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.331-337
    • /
    • 2005
  • This study aims at evaluation of component performance of a commercial micro gas turbine by detailed measurements of various system parameters. A test facility to measure performance of a micro gas turbine was set up. Performance parameters such as turbine exit temperature, exhaust gas temperature, engine inlet temperature, compressor discharge pressure and fuel flow rate were measured. Variations in measured data and estimated performance parameters were analyzed. In addition to overall engine performance, component characteristic parameters including the turbine inlet temperature, the compressor efficiency, the turbine efficiency, the recuperator effectiveness were estimated. Behaviors of the estimated characteristic parameters with operating condition change were examined.

  • PDF

A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station (가스충전소에서 작업복의 정전기 안전관리에 관한 연구)

  • Lee, Geum-Hwan;Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

A Study on the Gas Pulsation in a Horizontal Scroll Compressor (횡형 스크롤 압축기의 가스 맥동에 관한 연구)

  • Choi, Jin Sub;Kim, Hyun Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.41-45
    • /
    • 1999
  • Analytical and experimental investigations have been carried out on the gas pulsations in the discharge paths of a high-side horizontal scroll compressor, where the gas discharged from compression chamber is made to pass through several chambers inside the compressor shell. Model of Helmholtz resonators in series has been applied to this configuration to predict gas pulsation phenomena along the passages, and the calculation results have been compared with measured pressure time traces. Good agreements between the analytical and experimental results have been obtained. It has also been found that the compressor performance is somewhat affected by the size of individual chambers Inside the compressor shell.

  • PDF

Discharge Characteristics of Surface Discharge Type FFL for LCD Backlighting (LCD 백라이트용 면방전형 FFL의 방전 특성)

  • Lim, M.S.;Yun, S.H.;Shin, Y.S.;Jung, D.Y.;Kwon, S.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1786-1788
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp with High Luminance for LCD Backlighting, Liquid Crystal display(LCDs) demand the use of fluorescent lamp as the backlighting source. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. In spite of its simple structure, the lamp has uniform and stable discharge over entire volume. Till now, we measured the current-voltage(V-I), Firing Voltage, Sustain Voltage for 0.5mm, 1mm electrode gap. In experiment result, long gap cell structure cause high firing voltage. The rising in firing voltage in long gap structure could not be explained by paschen's law because of non-uniform electric field.

  • PDF

Enhancement of biodegradability of the Refractory Organic Substances in Aqueous Solution with Discharged Water Generating (DWG) System (방전시스템(Discharged Water Generator)을 이용한 난분해성 물질의 생분해능 향상에 관한 연구)

  • Yeo, Inho;Ryu, Seung Min;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.79-85
    • /
    • 2006
  • Innovated technique to oxidize pollutants has been developed. The technique for this study uses plasma discharge in 2-phase (Air-Water) and is called Discharged Water Generating (DWG) system. It produces electric arc which generates not only the physical decomposing power against the pollutants but also oxidants to sterilize pollutants depending on the inlet gas species. These physical and chemical products play an important role in COD decrease and biodegradability enhancement. The enhancement of biodegradability for the refractory organic substances in aqueous solution was estimated in this study. Argon discharge reduced NBDCOD of EDTA from 58.7mg/L to 38.8mg/L, but oxygen discharge and ozonation reduced it to 37.74mg/L and 38.73mg/L respectively. Furthermore, Argon discharge changed 1181mg/L of NBDCOD of dye effluent into 606mg/L but oxygen discharge and ozonation changed it into 888mg/L and 790mg/L respectively.

Analysis of characteristics of discharge in liquid

  • Kim, Ju-Sung;Min, Boo-Ki;Hong, Young-June;Kang, Seong-Oun;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.209.2-209.2
    • /
    • 2016
  • Up to now, Plasma applications are thought as a leading technology in industrial, chemical and even medical and biological field. Especially, Due to direct discharge in liquid with reaction in ambient solution, plasma in liquid is useful plasma technology. Such as electro-surgery, water purification, radical generation for synthesis. For using those plasma applications efficiently, plasma characteristics should be understood in advance. But discharge in liquid is not much well-known about its characteristics. And plasma discharge in solution is difficult to generate and analysis due to electrolysis, vaporization and radical generation. So, We make stable plasma discharge in solution(saline 0.9%) without input gas. We also analyze new type of plasma source in thermal and electrochemical view. And we check characteristics of plasma in liquid. For example, plasma density and radical density(OH) with optical emission, thermal energy with thermometer, electrical energy with oscilloscope and so on. And we try to explain the bubble and plasma formation with circuit analysis.

  • PDF

A study of Partial Discharge Condition Monitoring Equipment In the Ultra High Voltage Gas-Insulated Switchgear(GIS) for Digital Sub-station application (디지털 변전소 적용을 위한 초고압 GIS 부분방전 상태감시장치 개발 연구)

  • Kim, Young-Noh;Cho, Young-Jun;Choi, Chul-Gang;Hwang, Chul-Min;Choi, Jae-Ok;Gang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1380-1381
    • /
    • 2008
  • By applying the digital sub-station, the change of various protect and measuring equipments has been applying. This paper is analyzed that the development of GIS partial discharge condition monitoring equipment is suited to the electricity IT technology and digital sub-station. It's constitution apply to be able to suit the data to high rank for GIS partial discharge condition monitoring equipment that is suited digital sub-station and Watch-dog module that be able to monitor the inner communication of the GIS partial discharge equipment. And then it also be able to apply of GIS partial discharge equipment when digital sub-station is applied.

  • PDF

The Measurement of Three-Dimensional Temporal Behavior According to the Pressure in the Plasma Display Panel (플라즈마 디스플레이 패널에서 압력에 3차원 시간 분해 측정)

  • 최훈영;이석현;이승걸
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.476-480
    • /
    • 2003
  • In this paper, we have performed 3-dimensional time-resolving measurement of the Ne light emitted from the cell of plasma display panel(PDP) as a function of the pressure using the scanned point detecting system. From the temporal behavior results, we could analyze the discharge behavior of panel with Ne-Xe(4%) mixing gas and 300 torr, 400 torr and 500 torr pressure. At the top view of panel, the discharge of 300 torr panel starts at the 634 ns and ends at the 722 ns. The emission duration time is about 90 ns. The discharge of 400 torr panel starts at the 682 ns and ends at the 786 ns. the emission duration time is about 100 ns. Also, the discharge of 500 torr panel starts at the 770 ns and ends at the 826 ns. the emission duration time is about 56 ns. The discharge moves from inner edge of cathode electrode to outer cathode electrode forming arc type. In the side view of 300 torr, 400 torr and 500 torr an emission shows that the light is detected up to 180${\mu}{\textrm}{m}$, 150${\mu}{\textrm}{m}$ and 70${\mu}{\textrm}{m}$ height of barrier rib and the emission distribution of the 300 torr is wider than 400 torr, 500 torr.