• 제목/요약/키워드: Gas Discharge

검색결과 1,507건 처리시간 0.027초

$SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II) (Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II))

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

기체레이저의 여기를 위한 용량결합고주파(ccrf) 방전시스템 (Capacitively Coupled Radio Frequency Discharge System for Excitation of Gas Laser)

  • 최상태
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.19-26
    • /
    • 2006
  • 용량결합고주파(ccrf)방전은 홀로우음극방전이나, 직류방전에 비해서 방전관의 구조가 간단하고 균질한 플라즈마를 발생시키는 장점을 가지고 있다. 본 논문에서는 ccrf-방전을 기체레이저의 여기에 적용하기 위한 목표를 가지고 방전시스템을 선계, 제작하여 연속운전의 균질한 방전을 실현하였다. 13.56[MHz]의 rf-전력을 방전 내부로 효율적으로 결합하기 위해서 내부직경 5[mm]의 레이저방전관에 특수하게 제작된 rf-전극을 사용하였다. 또한 방전관의 임피던스가 rf-발생기의 풀력저항 50[$\Omega$]에 정합을 이루는 임피던스 정합회로를 개발하였다.

Long Gap Hump 전극구조를 가진 ac PDP에서의 Xe-Ne 가스의 방전 특성 연구 (A Study of Discharge Characteristics in Xe-Ne Gas Mixture for ac PDP with Long Gap Hump Electrode)

  • 허종철;옥정우;이돈규;이해준;이호준;박정후
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.155-159
    • /
    • 2009
  • To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.

복합방전형 오존발생기의 오존생성 및 NO 가스 제거특성 (Ozone Generation and NO Gas Removal Characteristics a Hybrid Discharge Type Ozonizer)

  • 송현직;이상석;신용철;김민회;박찬규;이광식;임창호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.278-280
    • /
    • 2006
  • A hybrid discharge type ozonizer, which is superposed silent and surface discharges, has been designed and manufactured to apply for Nitrogen Oxides(NO) gas removal. The ozonizer consists of three electrodes, and is classified three types of ozonizer by changing applied voltage. Investigation was carried out variance with the flow rate of supplied oxygen gas, discharge power and the sorts of superposed discharge type ozonizer. Moreover, $NO(1200[ppm])/N_2$ gas removal investigation was also conducted to apply for environment improvement field. Two kinds of NO gas removal investigations were conducted. It distinguishes the investigations into NO gas reaction method. According to these studies, maximum removal rate of 100[%] in NO gas was obtained, and 8334[ppm] and 3249[mg/h] of maximum ozone concentration and generation were also obtained respectively.

  • PDF

플라즈마 방전에 의한 $SO_x, NO_x$의 분해 (Decomposition of $SO_x, NO_x$ by Plasma Discharge)

  • 우인성;강현춘
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.73-77
    • /
    • 1999
  • In this study, $SO_2$ and $NO_2$ reduction have been investigated by using coil type plasma reactor. The experiments have been carried out changing discharge power, gas flow rate frequency and electrode style to obtain the decomposition rate. Decomposition rates of $SO_2$ and $NO_2$ were obtained 20~98% at gas flow rate 100ml/min~1,000ml/min and discharge power 5~25w respectively. The energy efficiency is very good at the high frequency power. The decomposition rate of $SO_2$ for 5kHz power supply is only 90%, but for 10kHz power supply is very high, more than 98% for 15w. The decomposition rate is increasing according to the residence time or the power consumption of the discharge. About 15W discharge power for 17$cm^2$ reactor is necessary to obtain the decomposition rate of $SO_2$ and $NO_2$ of more than 85% or 98%. From these experiments, the consumption power of the decomposition rate of 98% in 300ppm $NO_2$ gas in nitrogen gas proved to be 18W and 300ppm $SO_2$ gas to be 15w.

  • PDF

A Protection Circuit for the Power Supply of a Gas Discharge Lamp

  • Kim, Ho-Sung;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Jung, Hye-Man;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.777-783
    • /
    • 2010
  • In order to drive gas discharge lamps, DC-AC converters with a LCC resonant tank, whose output voltage is adjusted by a variable frequency control are frequently used. However, when they are activated by varying the operating frequency, converters are frequently damaged by unstable operation, due to the rising and falling of the operating frequency near the resonant frequency. To solve this problem, a simple protection circuit for the power supply of a gas discharge lamp is proposed in this paper. This circuit senses the primary current of the main transformer. Using this protection circuit, the operating frequency of the lamp driving inverter system is kept close to and on the right side of the resonant frequency and the inverter is always operated in the ZVS condition. The resulting stable variable frequency operation allows various gas discharge lamps to be tested without the risk of damaging the main switches, because the protection circuit can protect the power MOSFETs of bridge converters from abnormal conditions. The validity and effectiveness of the proposed protection circuit are verified through the experimental results.

SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석 (Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation)

  • 신한신;김남훈;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

수처리용 방전 리액터의 개발과 방전 발광의 분광학적 분석 연구 (The development of the discharge reactor for water purification and a spectroscopic study on its discharge emission)

  • 한상보;박재윤;김종석;정장근;고희석;박상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.581-582
    • /
    • 2005
  • In order to apply the discharge plasma processing. to industrial areas, the control of the chemical reaction mechanism is necessary. The hybrid plasma reactor was designed for the effective treatment of wastewater and hazardous volatile organic substances. This plasma reactor was similar to the barrier discharge, and surface discharge on the dielectric surface was propagated to the water surface strongly for the heterogeneous chemical reaction at the interface between the working gas and the water surface. The discharge emission in this discharge reactor was mainly $N_2$ second positive band in the case of $N_2$ or air gas atmosphere, and intensities from OH radicals in Ar gas atmosphere were stronger than in $N_2$ or air gas atmosphere. From this result, it is necessary to apply Ar gas for the effective generation of OH radicals in this plasma reactor.

  • PDF

Influence of ion mobilities on discharge characteristics of AC-PDPs

  • Lee, In-Sook;Choi, K.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.491-494
    • /
    • 2004
  • With recent experiments to add He atoms to the Ne-Xe discharge gas mixture for high luminous efficiency PDPs, we have performed simulations on a coplanar structured AC-PDP sustained in the three species He-Ne-Xe gas mixture. We found that the correct ion mobilities are essential to get the meaningful simulation results. We determined ion mobilities in the mixture gas and presented the calculated results regarding the influence of ion mobilities on discharge characteristics.

  • PDF

A Study on the Control of Luminous Color in Gas Discharge Tubes

  • Lee, Jong-Chan;Her, In-Sung;Park, Yong-Sung;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, pulsed discharge is used to control the luminous color in gas discharge tubes. The luminous color of the positive column in gas discharge tubes filled with Hg-Ar-Ne (1: 9, 60[Torr]) and having no phosphor material, varies from red to blue emitted by the Ne and Hg from the pulsed discharge. With changing of pulse-width and frequency, the electron temperature in the transient period affects changes to the residual ion and metastable atom densities. The first metastable atoms containing energy levels of about 16.6 [eV]have a very high probability that a collision will result in the ionization potential of Ar being 15.8 [eV]. The change of locus in the CIE chromaticity diagram with increasing pulse-width and frequency approves the variation of luminous color.