• Title/Summary/Keyword: Gas Discharge

Search Result 1,514, Processing Time 0.027 seconds

A Study on the Dielectric Breakdown Strength and Transparency of Dielectric Layer on the Discharge Electrodes in PDP (PDP에서 방전전극상의 유전층의 절연내력과 투명도에 관한 연구)

  • Lee, Sung-Hyun;Kim, Young-Kee;Chi, Sung-Won;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.379-381
    • /
    • 1997
  • The dielectric layers in AC plasma display panel(AC PDP) are essential to the discharge cell structure, because they protect metal electrodes from sputtering by positive ion and from a sheath of wall charges which are essential to memory function of AC PDP. Furthermore, this layer should be transparent because the visible light must pass through the layer. In this paper, the dielectric breakdown strength and transparency of the dielectric layer on the discharge electrodes are studied. The variables in this test are the dielectric layer thickness, dielectric firing condition, gas pressure, species of gas and so on.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.

Plasma etching of $SiO_2$ using dielectric barrier discharge in atmospheric pressure (Dielectric Barlier Discharge type 대기압 플라즈마 발생장치를 이용한 $SiO_2$ 식각에 관한 연구)

  • O, Jong-Sik;Park, Jae-Beom;;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.95-95
    • /
    • 2009
  • 대기압 플라즈마 발생장치를 이용한 식각장비 개발은 낮은 공정단가, 저온 공정, 다양한 표면처리 응용 효과와 같은 이점을 가지고 있어 현재, 많은 분야에서 연구되고 있다. 본 연구에서는, dielectric barrier discharge(DBD) 방식을 이용한 대기압 발생장치를 통해 평판형 디스플레이 제작에 응용이 가능한 $SiO_2$ 층의 식각에 대한 연구를 하였다. $N_2/NF_3$ gas 조합에 $CF_4$ 또는 $C_{4}F_{8}$ gas를 부가적으로 첨가하였다. 이때 N2 60 slm / NF3 600 sccm/CF4 7 slm/Ar 200 sccm의 gas composition에서 최대 260 nm/min의 식각 속도를 얻을 수 있었다.

  • PDF

Decomposition of Acetonitrile Using a Planar Type Dielectric Barrier Discharge Reactor Packed with Adsorption and Catalyst Materials (평판형 유전체 장벽 방전 반응기에서 충진물질에 따른 아세토나이트릴의 분해 특성)

  • 김관태;송영훈;김석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.157-165
    • /
    • 2003
  • A combined process of non-thermal plasma and catalytic technique has been investigated to treat $CH_3$CN gas in the atmosphere. A planar type dielectric barrier discharge (DBD) reactor has been used to generate the non-thermal plasma that produces various chemically active species, such as O, N, OH, $O_3$, ion, electrons, etc. Several different types of the beads. which are Molecular Sieve (MS) 5A, MS 13X, Pt/alumina beads, are packed into the DBD reactor, and have been tested to characterize the effects of adsorption and catalytic process on treating the $CH_3$CN gas in the DBD reactor. The test results showed that the operating power consumption and the amounts of the by-products of the non-thermal plasma process can be reduced by the assistance of the adsorption and catalytic process.

The effect of Gas Mixture Ratio on Discharge Characteristics of an AC PDP Cell

  • Lee, Hae-June;Lee, D.K.;Choi, J.H.;Cho, Y.S.;Park, H.D.;Lee, H.J.;Park, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.171-174
    • /
    • 2005
  • Experimental measurements are reported and compared with the results of a two-dimensional fluid simulation for the investigation of the discharge characteristics regarding the change of the mixture ratio of Ne-Xe-He noble gases. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage and the discharge time lag. The addition of He gas increases the brightness and the luminance efficiency. When Xe partial pressure is low, the luminance efficiency increases with the amount of He at the same total pressure. When Xe partial pressure is high, however, the luminance efficiency has a maximum value when the partial pressure of He is about 10% of the total pressure for a standard AC PDP cell with Xe fraction of $10{\sim}30%$.

  • PDF

Effects of Base Vacuum Level on Discharge Characteristics in Vacuum In-Line Sealing Process for High Efficient PDP

  • Kwon, Sang-Jik;Jang, Chan-Kyu
    • Journal of Information Display
    • /
    • v.5 no.4
    • /
    • pp.7-11
    • /
    • 2004
  • Effects of base vacuum level on the electrical and optical characteristics of the plasma display panel (PDP) were investigated. The relationship between efficiency and base vacuum level before filling discharge gas was analyzed. For the base vacuum level of $1{\times}10^{-4}$ torr, firing voltage of a 2-inch diagonal PDP panel was 232 V at the discharge gas pressure of 400 torr and luminous efficiency was 1.5 lm/W at 180V sustaining pulse. On the other hand for $1{\times}10^{-6}$torr, the firing voltage was reduced to 215 V and luminous efficiency was improved considerably to 2.5 lm/W. We successfully demonstrated the smooth operation of tip-less PDP fabricated using vacuum in-line sealing method.

A Theoretical Analysis of Voltage and Current in Low Pressure Mercury-Argon Mixture Gas Discharge with Frequency Variation (저압 수은-아르곤 혼합기체 방전의 주파수에 따른 전압, 전류 변화의 이론적 해석)

  • Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.23-27
    • /
    • 2005
  • A fluorescent lamp which uses low pressure mercury-argon gas discharge shows the maximum current and minimum lamp voltage near 1(kHz) source frequency at constant power. For explain these phenomena theoretically, in this paper a atomic level discharge model was made and particle density and electron temperature variation were calculated using numerical method.

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

ICCD Observation on Discharge Characteristics of 42-in. AC Plasma Display Panel Fabricated by Vacuum Sealing Method

  • Park, Choon-Sang;Tae, Heung-Sik;Kwon, Young-Kuk;Heo, Eun-Gi;Lee, Byung-Hak
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.320-323
    • /
    • 2007
  • The vacuum sealing method is adopted to minimize the residual impurity gas by enhancing a base vacuum level, and the resultant changes in the reset, address, and sustain discharge characteristics, such as a firing voltage, IR emission, and ICCD image, were examined in comparison with the conventional sealing method in the 42-in. AC-PDP. In the PDP cells fabricated by the vacuum sealing method, the ICCD observation illustrates that the discharge is initiated and extinguished very fast and its IR emission intensity is high.

  • PDF

Analysis of Oil Supply System of a R134a Rotary Vane Compressor (R134a 로타리 베인 압축기 급유 계통 해석)

  • Kim, Ho-Young;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.113-118
    • /
    • 2008
  • For a R134a rotary vane compressor used for car air conditioners, characteristics of gas compression and oil supply have been studied. The compressor model under investigation has the low volume ratio of suction to discharge volumes so that there occur flow reversal from discharge port to compression chamber as the leading vane passes over the discharge port. As a result, the volumetric and adiabatic efficiencies turn out to be relatively low compared to other types of displacement compressors. Oil supply mechanism has been comprehended for mathematical modeling and oil flow rate has been calculated for the individual oil passages. This study on the gas compression and oil supply of a rotary vane compressor can be applied to a future design practice on a similar type of compressor.

  • PDF