• 제목/요약/키워드: Gas Cooling

검색결과 1,095건 처리시간 0.025초

주택 주방의 리모델링 선호요인 및 실태에 관한 연구 (A Study on Residents' Remodeling Preference factors and the Actual Conditions in the Residential Kitchen)

  • 김남효
    • 한국실내디자인학회논문집
    • /
    • 제38호
    • /
    • pp.250-257
    • /
    • 2003
  • The purpose of this study is to analyze the varying characteristic factors for residential kitchen remodeling according to contemporary life style. The subjects of this investigation are collected through questionnaire from adult residents who live in Seoul, Korea. The collected cases are analyzed by using Spss-win. By using the vaimax method on the basis of factor analysis, the satisfaction of the actual conditions is under the influence of finished materials & function, sanitary installation, layout, cooling & heating apparatus, day lighting, air conditioning, and safety. The preference of kitchen remodeling Is affected by finished materials, function, environmental equipment, and air conditioning. The Need of kitchen facility is caused by working table, refrigerator, gas range, dish apparatus, and addition function.

튜브형상에 따른 배기가스 재순환 냉각 장치 열전달 성능 평가 (Heat Transfer Analysis of EGR Cooler with Different Tube Shape)

  • 손창현
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.112-117
    • /
    • 2007
  • With the Euro-4 regulation coming into effect, the domestic car industry is forced to look for newer options to reduce NOX in the exhaust. EGR(Exhaust Gas Recirculation) Cooler is an effective method for the reduction of NOX form a diesel engine. High efficiency, low pressure loss and compactness are desirable features of an EGR Cooler. The cooling performance of EGR depends on the shape of tubes and the location of the entrance and exit. This paper reports the computational work conducted to estimate the performance of EGR cooler with three different cross section tubes and a triangular spiral tube. Three dimensional computation results show that the triangular tube is more effective than circular and rectangular tube. The most effective geometry is a triangular spiral tube with offset inlet and outlet locations.

용융공정으로 제조한 $YBa_2Cu_3O_{7-x}$ 산화물의 미세조직에 미치는 기공의 영향 (Effects of Pores on the Microstructure of Melt-Processed $YBa_2Cu_3O_{7-x}$ Oxides)

  • 김찬중;홍계원
    • 한국분말재료학회지
    • /
    • 제8권2호
    • /
    • pp.117-123
    • /
    • 2001
  • Formation of pores in melt-processed $YBa_2Cu_3O_{7-x}$ (123) oxides and its effect on the microstructure were studied. Spherical pores with a size of a few tens of microns were formed due to the evolution of oxygen gas during melting of a 123 oxide. Some of pores were converted into liquid pockets by liquid filling, but others remained unfilled. The liquid pockets were converted into spherical 123 regions with a lower $Y_2BaCuO_5$ (211)density through the peritectic reaction during subsequent cooling, while the pores were entrapped into the periteictically grown 123 grains. The spherical 123 regions often consists of a residual melt due to the unbalanced peritectically reaction.

  • PDF

메탈파이버 버너의 예혼합 연소 및 화염급냉에 따른 NOx 배출 특성 (The Characteristics of NOx Emission for Premixed Combustion and Flame Rapid Cooling of MFB)

  • 김혁주;박병식;김종진;정해승
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제22회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.172-179
    • /
    • 2001
  • Experimental studies have been carried out to find out the characteristics of the heat transfer, combustion emission and noise in the boilers without any extra firing zone for complete combustion of fuel. For the experiments a burner of premixed type and some heat exchangers were designed and manufactured. Also test facilities including a data acquisition system and various measuring devices were set up in order to measure automatically the various temperatures and flow rates of water and combustion gas. Various experiments were performed to find out the heat transfer characteristics as well as combustion emission and noise. In general, the burner which has uniform holes in the burner nozzle plate generates big combustion noise . whistling. The noise reduction method is discussed in this study. Many experimental data such as noise level, the amount of pollutant emission and heat transfer rate for different combination of heat exchangers are given as comparison bases for numerical studies.

  • PDF

플레이트-휜형 흡수기의 흡수성능에 대한 연구 (The Study on Absorption Performance of a Plate-Fin Type Absorber)

  • 강인석;김남진;김종보
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.557-563
    • /
    • 2001
  • Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.

  • PDF

하수처리수이용 흡수식냉동사이클의 해석 (Analysis of Absorption Refrigeration Cycles to Utilize Treated Sewage)

  • 이용화
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.288-298
    • /
    • 1996
  • The gas-fired absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cycles with parallel or series flow type has been performed. The working fluid is Lithium Bromide and water solution. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The efficiency of a couple of cycles has been studied and simulation results show that higher coefficient of performance could be obtained for parallel flow type. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficent of performance in the paralledl flow type.

  • PDF

18Cr 페라이트계 스테인리스강의 용접특성 (Characteristics of 18Cr ferritic stainless steel welds)

  • 이원배;김정길;우인수;이종봉
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년 추계학술발표대회 개요집
    • /
    • pp.123-124
    • /
    • 2006
  • This study aimed at exploiting low heat input characteristic of laser welding to effectively control grain coarsening in the fusion zone(FZ) and heat affected zone(HAZ) of 1.5mm thick 18wt% Cr ferritic stainless steel weld. The study demonstrated that as compared with gas tungsten arc welding(GTAW), laser welding brought about significant grain refinement in the FZ and HAZ. However, the impact absorbed energy of GTA weld was superior than that of laser weld because the strengthening effect during welding and cooling stage was higher In laser weld than that in GTA weld. The coarser grains in each weld than base metal resulted in an inferior toughness.

  • PDF

Modification of a cosmological hydrodynamic code for more realistic baryonic physics

  • Chun, Kyungwon;Shin, Jihye;Kim, Sungsoo S.
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.45.1-45.1
    • /
    • 2014
  • structure of matters of Lambda cold dark matter (CDM) cosmology on detailed numerical simulations. To accomplish our research goal, we have added the following baryonic physics on the existing cosmological hydrodynamic code, Gadget-2: 1) radiative heating and cooling, 2) reionization of the Universe and UV shielding, 3) star formation, 4) energy and metallicity feedback by supernova. In addition, we included cluster formation to distinguish clustered star formation inside the very high density gas clumps from the field star formation. Our simulations cover a cubic box of a side length 4Mpc/h with 130 million particles. The mass of each particles is $3.4{\times}104Msun$, thus the GCs can be resolved with more than hundreds particles. We discuss various properties of the GCs such as mass function, specific frequency, baryon-to-dark matter ratio, metallicity, spatial distribution, and orbit eccentricity distribution as functions of redshift. We also discuss how the formation and evolution of the GCs are affected by UV shielding.

  • PDF

Self-Regulation of Star Formation Rates: an Equilibrium Vieww

  • Kim, Chang-Goo;Ostriker, Eve C.
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.55.2-55.2
    • /
    • 2016
  • In this talk, I will present a theoretical and numerical framework for self-regulation of the star formation rates (SFRs) in disk galaxies. The theory assumes (1) force balance between pressure support and the weight of the interstellar medum (ISM), (2) thermal balance between radiative cooling in the ISM and heating via FUV radiation from massive young stars, and (3) turbulent energy balance between dissipation in the ISM and driving by momentum injection of SNe. Numerical simulations show vigorous dynamics in the ISM at all times, but with proper temporal and spatial averages, all the expected balances hold. This leads to a scaling relation between mean SFRs and galactic gas and stellar properties, arising from the fundamental relationship between SFR surface density and the total midplane pressure.

  • PDF

종합병원의 환기설비 사례 연구 (A Case Study on the Ventilation System of the General hospital)

  • 정종림
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.