• Title/Summary/Keyword: Gas Clean Up

Search Result 147, Processing Time 0.03 seconds

R&D Status of NOx and Flue-gas Treatment Technologies in KIER (KIER의 NOx 및 연소배가스 처리기술 개발현황)

  • Min, Byoung-Moo;Choi, Sang-Il
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.295-300
    • /
    • 2003
  • In Korea, the emission standards for air pollutants will be more tighten from Jan. 2005. Especially, the new emission standards is focused on the nitrogen oxide. From this trend of standards, nitrogen oxide emission is hot issue in energy fields. Also, we have a new environmental problem, the carbon dioxide emission, which are related to the global warming. To solve the environmental problems, we must define the situation of clean-up technologies level in Korea and decide the direction of R&D for flue gas cleaning technologies. Now, this paper discus briefly on the De-NOx R&D activities and the large scale testing facility for flue gas clean-up technologies in Korea Institute of Energy Research. These discussions are contribute to the increasing of the R&D activities for flue gas clean-up technologies in Korea.

  • PDF

The Effect of Partitioning Porous Plate on Bubble Behavior and Gas Hold-up in a Bench Scale (0.36 m × 22 m) Trayed Bubble Column (벤치스케일(0.36 m × 22 m) 다단형 기포탑에서 다공판이 기포의 거동 및 기체 체류량에 미치는 영향)

  • Yang, Jung Hoon;Hur, Young Gul;Lee, Ho-Tae;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Park, Ji Chan;Jung, Heon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.505-510
    • /
    • 2012
  • The gas hold-up has a strong relationship with the size distribution and rising velocities of bubbles in a bubble column. Therefore, many previous researchers have studied on the hydrodynamics focusing on the bubble size variation in bubble column. In this study, the bubble behavior was influenced by partitioning porous plates installed at a certain height in a trayed bubble column. The gas hold-up was increased in non-sparging region (H/D > 5) as well as sparging region. We identified the effect of the partitioning porous plate using three trayed bubble columns with different reactor geometries. Furthermore, the bubble break-up frequency and size distribution were observed before and after individual bubbles penetrated through the plate. The arrangement of the plates was also investigated using a 0.15-m-in-diameter bubble column. Based on the result, we applied this design concept to a 0.36-m-in-diameter, 22 m tall trayed bubble column and identified the effect of the partitioning porous plate on the gas hold-up increase.

폐기물 매립지 토양에서의 PCBs 분석법

  • Lee Jeong-Hwa;Jeon Chi-Wan;Jeong Yeong-Uk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.199-201
    • /
    • 2005
  • This paper describes a simple procedure for the quantitative analysis of 7 PCBs (polychlorinated biphenyls) in soils on the waste reclaimed land, The procedure involved sample clean up using silicagel column, acetonitrile partition and sulfuric acid procedures. The instrumental technique is applied GC/PDD(gas chromatography/pulsed discharge detector) and GC/ECD(gas chromatography/electron capture detector). Concentration of $sub-{\mu}g/g$ level was attainable with 20g soils on the waste reclaimed land.

  • PDF

The analysis of the effect on the temperature of Hot Gas Clean-Up for IGCC system (고온정제 온도에 따른 IGCC 시스템 성능 영향 분석)

  • 서석빈;김종진;이윤경;안달홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.47-51
    • /
    • 1999
  • 차세대 석탄가스화복합발전(Integrated Gasification Combined Cycle; IGCC)으로써 고온정제(Hot Gas Clean-up; HGCU)는 고온고압의 석탄가스 중에 있는 불순물을 고온고압에서 제거하는 기술이다. 현재 이 기술에 대한 연구가 국내외적으로 활발히 이루어지고 있으며 특히 미국 에너지성에서는 2000년까지 플랜트 효율 45%의 건식 고온정제를 채용한 IGCC 시스템을 개발 중에 있으며 나아가 목표 효율 50% 이상으로 건식 고온 정제뿐 아니라 차세대 가스터빈을 채용한 시스템으로 2010년 개발을 목표로 하고 있다.(중략)

  • PDF

Aerosol Filtration/Sampling Device Based on Irrigated Rotating Wires

  • M. J. Shaw;M. R. Kuhlman;;J. A. Gieseke
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.265-267
    • /
    • 2000
  • The objective of this study is to analyze, design and evaluate a new gas cleanup or sampling system that will remove erosive, corrosive, and fouling contaminants present in an effluent stream as either solid or liquid particles providing a clean gas stream. The gas clean-up or sampling system considered in this study is an irrigated, rotating element device. The device consists of a central disk-like hub from which emanate radially wires or cylindrical elements. (omitted)

  • PDF

Performance Evaluation of the Gas Turbine for Integrated Ossification Combined Cycle (석탄가스화 복합발전용 가스터빈의 성능 평가)

  • Lee, Chan;Lee, Jin-Wook;Yun, Yong-Seung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.7-14
    • /
    • 1999
  • This simulation method is developed by using GateCycle code for the performance evaluation of the gas turbine in IGCC(Integrated Gasification Combined Cycle) power plant that uses clean coal gas fuel derived from coal gasification and gas clean-up processes and it is integrated with ASU(Air Separation Unit). In the present simulation method, thermodynamic calculation procedure is incorporated with compressor performance map and expander choking models for considering the off-design effects due to coal gas firing and ASU integration. With the clean coal gases produced through commercially available chemical processes, their compatibility as IGCC gas turbine fuel is investigated in the aspects the overall performance of the gas turbine system. The predictions by the present method show that the reduction of the air extraction from gas turbine to ASU results in a remarkable increase in the efficiency and net power of gas turbines, but it is accompanied with a shift of compressor operation point toward to surge limit. In addition, the present analysis results reveal the influence of compressor performance characteristics of gas turbine have to be carefully examined in designing the ASU integration process and evaluating the overall performance parameters of the gas turbine in IGCC Power plant.

  • PDF

MEMBRANE PROCESSES IN ENVIRONMENTAL TECHNOLOGY

  • Blume, I.;Smolders, C.A.
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.1-20
    • /
    • 1992
  • Classical membrane processes like microfiltration (MF), ultrafiltration (UF) and reverse osmosis (RO) are being applied in the last years more frequently in environmental and effluent process problems. Newer technologies and developments like pervaporation (PV) and gas sepaxation (GS) recently found commercial applications in the treatment of waste waters and gas streams. The incentive here is either the clean-up from organic components to comply with federal emission regulations or the recovery of the organics for economical reasons. Processes still in their development stage are combinations of chemical reactions with membrane processes to separate and treat $SO_x$ and $NO_x$ laden waste gas streams in the clean-up of stack-gases. In this paper we will first give a short overview of the more recent developments in MF, UF and RO. This is followed by a closer look on newer technologies applied in environmental problems. The applications looked at are the recovery of organic components from solvent laden gas streams and the separation of organic volatiles from aqueous waste waters via pervaporation. Technical solutions, the advantages and disadvantages of the processes and. where possible, cost estimations will be presented.

  • PDF

Preparation of Synthesis Gas from Methane in a Capacitive rf Discharge (용량성 rf 플라즈마를 이용한 메탄으로부터의 합성가스 제조)

  • Song, Hyung Keun;Choi, Jae-Wook;Lee, Hwaung;Kim, Seung-Soo;Na, Byung-Ki
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.138-144
    • /
    • 2006
  • Conversion of methane to synthesis gas in a capacitive rf plasma at low pressure was experimentally studied. In this plasma, electrons which had sufficient energy-level collided with the molecules of methane or oxygen-containing gas, which were than activated and converted to synthesis gas. The effect of input power, various oxygen-containing gas and composition of the gas mixture were investigated. The conversion of methane reached up to 100%. In all cases, hydrogen and carbon oxide were produced as primary products, and other compounds was generated. The conversion of methane and the yield of hydrogen and carbon oxides were increased with increasing the input power. Depending on the oxygen-containing gases, the composition of synthesis gas was varied.

  • PDF

Determination of Thiamin by Gas-chromatography (기체크로마토그래피법에 의한 티아민 분석)

  • Yoo, Ji-Sang;Moon, Dong-Cheul;Hong, Sung-Hwa;Han, Kun;Kim, Bak-Kwang
    • YAKHAK HOEJI
    • /
    • v.33 no.3
    • /
    • pp.156-160
    • /
    • 1989
  • A gas-chromatographic determination method of thiamin which use a quantitative cleavage of thiamin to 4-methyl-5-(2-hydroxyethyl)thiazol [I] and solvent extraction of the analyte prior to GC injection was modified. A column chromatographic procedure using a reversed phase, high capacity solid phase cartridge was applied to the clean-up of the analyte. Thiazol derivative[I] was quantitatively recovered upon the column method. Acetanilide, an internal standard, has a good recovery through the analytical procedure. The method has analytical precision of 2% or less in the coefficient of variation.

  • PDF