• 제목/요약/키워드: Gas Chromatography/mass spectrometry

검색결과 978건 처리시간 0.026초

몇가지 박과 식물 종자유중의 Sterol 조성 (Sterol Compositions in Some Cucurbitaceae Vegetable Oils)

  • 정태명;양민석
    • 대한화학회지
    • /
    • 제21권3호
    • /
    • pp.193-203
    • /
    • 1977
  • 오이, 수박, 수세미, 박, 하늘수박의 다섯가지 박과식물 종자유에서 세가지 스테롤 플랙숀을 박층 크로마토그래피로 나누고 각 플랙숀의 조성을 가스크로와 가스크로에 연결된 질량분석법으로 밝혔다. 이중 4-데스메틸스테롤 플랙숀에서 ${\alpha}$-Spinasterol, ${\Delta}^{7,22,25}$-stigmastatrienol 및 ${\Delta}^{7,25}$-stigmastadienol를 단리(單離)하여 IR, NMR 및 질량분석법으로 동정(同定)하였다.

  • PDF

Gas Chromatography/Mass Spectrometry를 이용한 식품보존료의 동시분석방법 연구 (Simultaneous Determination of Preservatives in Food by GC/MS)

  • 김승기;노동석
    • 한국식품위생안전성학회지
    • /
    • 제14권2호
    • /
    • pp.140-145
    • /
    • 1999
  • Analytical method for preservatives in food was developed using gas chromatography/mass spectrometry (GC/MS). Propionic acid, sorbic acid, benzoic acid, ethyl salicylate, ethyl p-hydroxy benzoate, iso-propyl p-hydroxy benzoate, n-propyl p-hydroxy benzoate, iso-butyl p-hydroxy benzoate, n-butyl p-hydroxy benzoate, p-hydroxy benzoic acid and dehydro acetic acid were extracted from cooling beverage with diethyl ether. The polar hydroxyl and carboxyl groups of food preservatives were derivatized with N-methyl-N-tert-butyldimethylisilyl-trifluoroscetamide (MTBSTFA) to form the corresponding tert-bytyldimethyl-silylated derivatives, and submitted to GC/MS analysis. The mass spectra of the derivatives were investigated for the selection of monitoring ions for multi-residue analysis of 11 preservatives by GC/MS. The macro program was also developed for the qualitative analysis of these preservatives in food.

  • PDF

Urinary Metabolism and Excretion of Carbinoxamine after Oral Administration to Man

  • Jung, Byung-Hwa;Chung, Bong-Chul;Park, Jong-Sei
    • Biomolecules & Therapeutics
    • /
    • 제4권3호
    • /
    • pp.251-256
    • /
    • 1996
  • The metabolism of carbinoxamine, 2-[(4-chlorophenyl)-2-pyridinyl-methoxy]-N, N-dimethylethaneamine, was studied in adult male volunteers after an oral dose of 15 mg. Solvent extracts of urine obtained with or without enzyme hydrolysis were analyzed by gas chromatography-mass spectrometry after derivatization with MSTFA/TMSCl (N-methyl-N-trimethylsilyltrifluoroacetamide/trimethyl chlorosilane). The structures of metabolites were determined based on the electron impact (EI) and chemical ionization (CI) mass spectra. Nonconjugated metabolites identified in the urine were carbinoxamine, nor-carbinoxamine, and bits-nor-carbinoxamine. Parent drug, nor-carbinoxamine, and bits-nor-carbinoxamine were also detected as conjugated forms. These metabolites observed in human urine were different from those previously reported in the rat. Urinary excretions of carbinoxamine were reached to maxima in 4 hours after drug administration with 4.9%-8.1% and 2.5-4.2% of the dose excreted during 24 h as carbinoxamine and its glucuronide, respectively.

  • PDF

Determination of panthenol, cholecalciferol and tocopherol in cosmetic products by gas chromatography-mass spectrometry in SIM mode

  • Hye-Jin Jeong;Myo
    • 대한화장품학회지
    • /
    • 제22권2호
    • /
    • pp.153-160
    • /
    • 1996
  • A novel simple method to detect vitamins in cosmetic products by gas chromatography-mass spectrometry(GC-MS) has been developed. Three vitamins(panthenol, cholecalciferol and tocopherol) were used for this study. Vitamins were prepared by dissolving in tetrahydrofuran(THF), and silylated with bis-trimethylsilyltrifluoroacetamide-trichloromethylsilane(BSTFA). Silated vitamins were separated on a fuses-silica capillary column coated with DB-5. The identification of each vitamin was accomplished by retention time and mass spectrum library search with a computer, and the quantitation was made in the selected-ion monitoring(SIM) mode of GC-MS. SIM mode had given sensitivity to determine 50pg of panthenol, 285pg of cholecalciferol and 130pg of tocopherol. Linearity was maintained over the range 0.005-0.20% for each vitamin. Each cosmetic product(i.e. hair tonic and lotion) was found to contain amounts of the vitamins. This method was sensitive and gave 77.5-99.9% recovery of each vitamin from these cosmetic products. From these results, we concluded that silylation with BSTFA followed by GC-MS analysis allows the simple, covenient and exact determination of panthenol, cholecalciferol and tocopherol.

  • PDF

Simultaneous Determination of 4-Nitrotoluene and Benzophenone in Ground Water and Soil by Gas Chromatography-Mass Spectroscopy

  • Kwon, Oh-Seung;Kim, Eun-Young;Ryu, Jae-Chun
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.59-69
    • /
    • 2003
  • Benzophenone (BZP) and 4-nitrotoluene (4-NT) listed as endocrine disrupting chemicals are suspected to contaminate ground water sites and soil. Analytical method for simultaneous determination of the two chemicals in soil and ground water was developed by gas chromatography-mass spectrometry. Water (100 ml) was extracted with hexane, and soil (10 g) was extracted with methanol and hexane. Recovery in water was >72% for BZP and 90-118% for 4-NT. Recovery for 4-NT and BZP in soil was 51-59% with coefficient variation of less than 19.5%. Calibration curves showed a good linearity with $r^2=0.997$. In water and soil collected at nation-wide sites, BZP was found at 5 sites among 43 water sites at the concentration of $14.87{\pm}3.83ng/100 ml$. No 4-NT was found. It is suggested that this method is appropriate to the simultaneous quantitation of 4-NT and BZP in ground water and soil samples.

Simultaneous detection of five biocides in household products by gas chromatography-mass spectrometry

  • Choi, Kyeong-Yun;Lim, Hyun-Hee;Shin, Ho-Sang
    • 분석과학
    • /
    • 제35권5호
    • /
    • pp.197-204
    • /
    • 2022
  • A gas chromatography-mass spectrometric method was developed for determining 5-chloro-2-methyl-4-isothiazolin-3-one (CMIT), 2-methyl-4-isothiazolin-3-one (MIT), 1,2-benzisothiazolin-3-one (BIT), 3-iodo-2-propynyl butyl carbamic acid (IPBC) and benzoic acid (BA) in household products. A 0.5 g sample was placed in a test tube and dissolved with 5 mL water, 5 mL methylene chloride and 1.0 mL methanol. The solution was extracted by ultra-sonication followed by mechanical shaking using the salting out effect. Under the established condition, the lowest quantification limits of all analytes were in the range of 0.04-10 mg/kg and their relative standard deviations were less than 8.0 %. The method was used to analyze 10 household products. As a result of analyzing 10 household products, MIT was detected in the range of 1.2-3.5 mg/kg in 3 of 10 samples, CMIT was detected in the range of 2.6-8.2 mg/kg in 3 of 10 samples, and BA was detected in the range of 5.0-15 mg/kg in 4 of 10 samples. Meanwhile, BIT and IPBC were not detected in any of the products. It has been shown that this method can be used for the simultaneous determination of biocides with various physical and chemical properties in household products.

Identification of Homoserine Lactone Derivatives Using the Methionine Functionalized Solid Phase Synthesis by Gas Chromatography/Mass Spectrometry

  • Moon, Hong-Sik
    • Archives of Pharmacal Research
    • /
    • 제27권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Combinatorial homoserine lactone mixtures and individual products were obtained from the methionine-functionalized resin in solid-phase synthesis. The four-step process consisting of a coupling step of an N-Fmoc-L-methionine, deprotection of N-Fmoc group, N-coupling with a carboxylic acid, and cleavage reaction through a polymer supported strategy is described. Gas chromatography-mass selective detector (GC-MSD) techniques provide the most powerful methods for identifying both the combinatorial mixtures and individual products.

MEASUREMENT OF PESTICIDES RESIDUES USING SPECTROSCOPY ON AGRICULTURAL PRODUCTS

  • Kim, Y. W.;S. H. Noh
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.525-532
    • /
    • 2000
  • A new spectroscopic method for pesticide residues detection on agricultural products was developed. The general determination methods are high performance liquid chromatography (HPLC), gas chromatography (GC) or GC-mass spectrometry. They have provided relatively good detection limit and accuracy with complicated and time-consuming (5hrs above) procedures. In addition freshness is very important for evaluating qualities of agricultural products. This requires a simple and fast method for detection of pesticides. Reflectance, transmittance and fluorescence spectrometry of pesticides were tested using UV range because most of pesticides contain conjugation band in the molecular structures. Fluorescence spectrometry showed better sensitive to detect pesticide residues than did reflectance and transmittance spectrometry. Intensity and shape of fluorescence spectra showed different patterns with different structures of pesticides. Detection limit for fluorescence spectrometry was 0.1 ppm to 10 ppm depending on the structures of pesticides. Application of fluorescence spectrometry appears to be an easy method for detection of pesticide residues on agricultural products.

  • PDF

Headspace 가스크로마토그라피를 이용한 대두유 산화진행도의 객관적 평가방법 (Headspace gas chromatographic analysis as an objective method for measuring rancidity in soybean oil)

  • 전호남;김재욱
    • Applied Biological Chemistry
    • /
    • 제34권2호
    • /
    • pp.154-161
    • /
    • 1991
  • Headspace 가스크로마토그라피를 이용한 휘발성 산화생성물 분석으로 대두유의 산화진행도를 객관적으로 평가할 수 있는 방법을 연구하기 위하여, GC 주입부에 들어가는 splitless mode glass liner insert에 Tenax GC를 충전하여 휘발성 산화생성물을 효율적으로 포집 및 용출할 수 있는 장치를 고안하였으며, 시판 대두유를 poIyethylene용기에 담은 후 뚜껑을 닫아 밀봉하여 일정한 조건으로 저장하면서, 저장 기간에 따른 산패취의 변화를 관능검사를 통하여 평가하고 동시에 휘발성 산화생성물을 headspace gas chromatography를 이용하여 분석하였다. 23종의 휘발성 산화생성물이 gas chromatography 및 gas chromatography-mass spectrometry에 의하여 검출되었으며, 저장 기간에 따른 penatanal과 hexanal의 생성을 관능검사 결과와 상관 분석을 실시한 결과 상관 계수가 각각 0.990 및 0.994의 값을 보였다. 따라서 headspace 가스크로마토그라피를 이용하여 polyethylene 용기에 포장된 대두유의 휘발성 산화생성물중 pentanal과 hexanal을 분석하면 대두유의 산화진행도를 객관적으로 평가할 수 있음을 알 수 있었다.

  • PDF