• Title/Summary/Keyword: Gap parameter

Search Result 307, Processing Time 0.028 seconds

A study on numerical modeling method considering gap parameter and backfill grouting of the shield TBM tunnel (쉴드 TBM 터널의 gap parameter와 뒤채움재를 고려한 수치모델링 방법에 대한 연구)

  • You, Kwang-Ho;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.799-812
    • /
    • 2017
  • Backfill grouting and realistic convergence distribution were not properly considered in previous studies on 2D numerical analysis of a shield TBM tunnel. In this study, a modeling method was suggested to cope with this problem by considering a realistic convergence distribution and proper properties of backfill grouting. To this end, the influence of gap parameter and depth of rock cover on volume loss and composed of ground volume loss around tunnel excavation and surface volume loss were analyzed with a single layer of weathered soil. As a result, most of surface settlements were occurred immediately after excavation. Additional, as depth of rock cover and gap parameter increased, the influence range of surface settlement curves obtained from 2D numerical analyses became broader than a suggested theoretical equation. Therefore, it is inferred that gap parameter should be applied based on load distribution ratio and the property of backfill grouting properly considered for the estimation of the precise behavior of a shield TBM tunnel in 2D numerical analysis.

A Study on the Gap Parameter in Sand by Scale Model Test (축소모형실험을 통한 사질토지반에서 Gap Parameter의 연구)

  • Kim, Sang-Hwan;Kang, Jun-Gu;Seo, Yun-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1343-1349
    • /
    • 2010
  • This paper presents the behavior of the soil based on the Gap Parameter during the Shield TBM tunnel excavation in sandy soil. This study reproduced the tunnel before and after the excavation according to the diameter of the tunnel, water ratio and depth to execute a Scaled Model Test and analyzed the behavior change of the upper soil. As a result, tunneling after for soil stress decreased was similar in all the Case. In addition, the soil stress decreased was in water ratio increases.

  • PDF

Enhancement of Signal Transmission Characteristics Using Structural Changes in Silicone Rubber Socket (실리콘 러버 소켓의 구조 변경을 통한 신호 전달 특성 향상)

  • Seona Kim;Moonjung Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.104-109
    • /
    • 2024
  • In this paper, we propose structures of a socket that can improve signal transmission characteristics compared to the existing silicone rubber socket. A coaxial rubber socket was proposed to improve signal distortion due to electromagnetic interference between signal lines. And an air gap rubber socket was proposed to improve the degradation of reflection characteristics due to high dielectric constant. Using a 3D electromagnetic field simulator, the S-parameter and crosstalk of the three sockets were compared and the signal transmission characteristics were analyzed. In both coaxial rubber socket and the air gap rubber socket, S-parameter and crosstalk were improved compared to the silicone rubber socket. Among them, the air gap rubber socket was the best for S-parameter, and the coaxial rubber socket was the best for crosstalk.

  • PDF

Optical Properties of $I^B-AI-VI^B_2$$I^B-AI-VI^B_2 :Co^{2+}$ Crystals ($I^B-AI-VI^B_2$$I^B-AI-VI^B_2 :Co^{2+}$결정의 광학적 특성연구)

  • 김화택;김창대;윤창선;진문석;최성휴
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.3
    • /
    • pp.334-341
    • /
    • 1995
  • IB-AI-VIB2 및 IB-AI-VIB2 :Co2+ 결정을 고순도 원소를 출발 물질로 하고 iodine을 수송 매체로 사용하여 chemical transport reaction method로 성장시켰다. 성장된 결정의 결정구조는 chalcopyrite 구조였으며, energy gap은 direct band gap으로 3.514~1.814 eV 정도로 주어졌으며, cobalt를 불순물로 첨가할 때 energy gap은 감소하였다. IB-AI-VIB2 :Co2+ 결정에서 첨가된 cobalt가 모체결정의 Td symmetry site에 Co2+ ion으로 위치하여, Co2+ ion의 energy 준위 사이의 전자전이에 기인하는 불순물 광흡수 peaks가 나타났다. 이 불순물 광흡수 peaks에 결정장 이론을 적용하여 구산 1st-order spin-orbit coupling parameter(λ)는 -183~ -189cm-1정도였고, 2nd-order spin-orbit coupling parameter(P)는 225~239 cm-1정도였으며, crystal field parameter(Dq)는 328~395cm-1, Racah parameter(B)는 531~552cm-1정도였다.

  • PDF

Reliability analysis of surface settlement during shield TBM tunneling (쉴드 TBM 터널 굴착시 지표침하에 관한 신뢰성해석)

  • Han, Myeong-Sik;Cho, Kuk-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.3
    • /
    • pp.305-318
    • /
    • 2016
  • This study is to evaluate the uncertainty of the soil parameters associated with the Gap parameter during shield TBM tunnel excavation of ${\bigcirc}{\bigcirc}$ International Airport Terminal 2 connecting railway construction basic design. And This study is to evaluate the adequacy of the shield TBM design by performing a reliability analysis of the Surface settlement. In addition, By analyzing the reliability indices of the design constants and Sensitivity probability of failure to be used in designing an integer parameter Gap, and By evaluating the design constants of a great influence on the surface subsidence, it was to provide a basis for carrying out an optimum design.

New Generation Gap Models for Evolutionary Algorithm in Real Parameter Optimization (실수최적화 진화 알고리즘을 위한 새로운 세대차 모델)

  • Choi, Jun-Seok;Seo, Ki-Sung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.1
    • /
    • pp.62-68
    • /
    • 2009
  • Two new generation gap models with modified parent-centric recombination(PCX) operator are proposed. First, the self-adaptation generation gap(SGG) model is a control method that keeps a replaced probability of parents by offspring to a certain level which obtains better performance. Second, virtual cluster generation gap(VCGG) is provided to extend distances among parents using clustering, which causes it to diversify individuals. In this model, distances among parents can be controlled by size of clusters. To demonstrate the effectiveness of our two proposed approaches, experiments for three standard test problems are executed and compared to most competing current approaches, CMA-ES and Generalized Generation Gap(G3) with PCX. It is shown two proposed methods are superior to consistently other approaches in the study.

A study on Gap Parameter and Influence Area of Ground Settlement Using Back Analysis Constructed by Shield TBM with Shallow Depth (천층터널 쉴드TBM에서 역해석을 이용한 Gap Parameter 및 지표침하 영향범위에 대한 연구)

  • Koh, Sung-Yil;Kwon, Sung-Ju;Hwang, Chang-Hee;Kim, Sang-In;Choo, Seok-Yeon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1509-1518
    • /
    • 2011
  • Shield TBM tunneling method has been getting the spotlight for urban tunneling. It can be minimized the civil complaint during construction and possible safe tunneling. But the settlement has occurred inevitably due to characteristics of shield TBM equipment. For this reason, the civil complaint can occur in urban areas when tunnel with shallow depth passes through neighboring building or residential area. In this study, the occurrence factors of settlement according to shield TBM tunneling and the tendency of ground settlement by strata condition had analyzed. It is suggested that the practical settlement estimation method and minimizing method of ground settlement under simultaneous backfill grouting condition through measurement results and back analysis data using gap parameter.

  • PDF

Necessary Conditions of Optimal Distributed Parameter Control Systems (분포정수계통의 최적제어 필요조건)

  • Kyung Gap Yang
    • 전기의세계
    • /
    • v.19 no.2
    • /
    • pp.21-23
    • /
    • 1970
  • Necessary conditions of optimal distributed parameter control systems, Hamiltons coanonical equations, welerstress condition, transversality condition and boundary condition are obtained, when the control function is constrained and the performance index takes on the general form. Also it is concluded that the lumped parameter system is the special case of the distributed parameter system.

  • PDF

Time Difference Characteristics of GPS Carrier Phase (GPS 반송파의 시각차분 특성)

  • You, Ho;Lee, Eun-Sung;Lee, Young-Jea;Jee, Gyu-In;Nam, Gi-Wook;Jun, Hyang-Sig
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.66-72
    • /
    • 2005
  • As one of the methods that determine position using GPS carrier phase without the resolution of integer ambiguity, the characteristics of the time difference is analyzed in this paper. When determining position by the needed accuracy, the difference time gap becomes an important factor. It is said that accuracy is improved as the difference time gap is getting large, and finally the centimeter level accuracy is achieved after a certain difference time gap. In this paper, the characteristics of the time difference is analyzed using real data and a new parameter is proposed to predict the resulting position accuracy. The difference time gap when position error is converged to the centimeter level is estimated with the proposed parameter.

Power Loss Calculation of High Frequency Transformers

  • Choi Geun-Soo;Yoon Shin-Yong;Baek Soo-Hyun;Kim Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.338-342
    • /
    • 2006
  • This paper analyzed the power loss of transformers considering the magnetic component. For this, each winding strategy and the effect of air gap between the ferrite core have been an important variable for optimal parameter calculation. Inductors are very well known design rules to devise, but the performance of the flyback converter as a function of transformer winding strategy has not been fully developed. The transformer analysis tool used was PExpert. The influence of the insulator thickness, effect of the air gap, how the window height and variation of the capacitive value effects the coil and insulator materials are some of parameters that have been analyzed in this work. The parameter analysis is calculated to a high frequency of 48[kHz]. Therefore, the final goal of this paper was to calculate and adjust the parameters according to the method of winding array and air gap minimizing the power loss.