• Title/Summary/Keyword: Gap Test

Search Result 1,248, Processing Time 0.038 seconds

Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • PURPOSE. One of the most important factors in evaluating the quality of fixed dental prostheses (FDPs) is their gap. The purpose of this study was to compare the marginal and internal gap of two different metal-ceramic crowns, casting and selective laser sintering (SLS), before and after porcelain firing. Furthermore, this study evaluated whether metal-ceramic crowns made using the SLS have the same clinical acceptability as crowns made by the traditional casting. MATERIALS AND METHODS. The 10 study models were produced using stone. The 20 specimens were produced using the casting and the SLS methods; 10 samples were made in each group. After the core gap measurements, 10 metal-ceramic crowns in each group were finished using the conventional technique of firing porcelain. The gap of the metal-ceramic crowns was measured. The marginal and internal gaps were measured by two-dimensional and three-dimensional replica techniques, respectively. The Wilcoxon signed-rank test, the Wilcoxon rank-sum test and nonparametric ANCOVA were used for statistical analysis (${\alpha}$=.05). RESULTS. In both groups, the gap increased after completion of the metal-ceramic crown compared to the core. In all measured areas, the gap of the metal cores and metal-ceramic crowns produced by the SLS was greater than that of the metal cores and metal-ceramic crowns produced using the casting. Statistically significant differences were found between cast and SLS (metal cores and metal-ceramic crown). CONCLUSION. Although the gap of the FDPs produced by the SLS was greater than that of the FDPs produced by the conventional casting in all measured areas, none exceeded the clinically acceptable range.

Wind-induced self-excited vibrations of a twin-deck bridge and the effects of gap-width

  • Qin, X.R.;Kwok, K.C.S.;Fok, C.H.;Hitchcock, P.A.;Xu, Y.L.
    • Wind and Structures
    • /
    • v.10 no.5
    • /
    • pp.463-479
    • /
    • 2007
  • A series of wind tunnel sectional model dynamic tests of a twin-deck bridge were conducted at the CLP Power Wind/Wave Tunnel Facility (WWTF) of The Hong Kong University of Science and Technology (HKUST) to investigate the effects of gap-width on the self-excited vibrations and the dynamic and aerodynamic characteristics of the bridge. Five 2.9 m long models with different gap-widths were fabricated and suspended in the wind tunnel to simulate a two-degrees-of-freedom (2DOF) bridge dynamic system, free to vibrate in both vertical and torsional directions. The mass, vertical frequency, and the torsional-to-vertical frequency ratio of the 2DOF systems were fixed to emphasize the effects of gap-width. A free-vibration test methodology was employed and the Eigensystem Realization Algorithm (ERA) was utilized to extract the eight flutter derivatives and the modal parameters from the coupled free-decay responses. The results of the zero gap-width configuration were in reasonable agreement with the theoretical values for an ideal thin flat plate in smooth flow and the published results of models with similar cross-sections, thus validating the experimental and analytical techniques utilized in this study. The methodology was further verified by the comparison between the measured and predicted free-decay responses. A comparison of results for different gap-widths revealed that variations of the gap-width mainly affect the torsional damping property, and that the configurations with greater gap-widths show a higher torsional damping ratio and hence stronger aerodynamic stability of the bridge.

Comparison of the fit of the coping pattern constructed by manual and CAD/CAM, depending on the margin of the abutment tooth (지대치 변연 형태에 따른 수작업과 CAD/CAM으로 제작한 coping 패턴의 적합도 비교)

  • Han, Min-soo;Kwon, Eun-Ja;Chio, Esther;Kim, Si-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6611-6617
    • /
    • 2015
  • The purpose of this study is to compare the marginal and internal fit of metal and zirconia coping which is fabricated by manual and CAD/CAM(Computer Aided Design/Computer Aided Manufacturing). The model is prepared with Urethane material and two abutment teeth are fabricated with a knife and chamfer margin. Silicon replica technique is used to measure the marginal fit of manually fabricated and the CAD/CAM coping. Internal fitting level is measured with a microscope and the image is captured with a CCD camera. The distance between abutment teeth and coping is measured with a callibrated image analyzer software; marginal opening (MO), marginal gap (MG), internal gap (IG) at maximum curvature area, axial gap (AG), and occlusal gap (OG). Two-way ANOVA test is applied to compare fabrication technique and to analysis of abutment pattern. In addition, one-way ANOVA and Scheffe's test is used to analyze each parameter of the test. The result shows that the fit is < $120{\mu}m$ except OG of CAD/CAM and MO of knife margin. The CAD/CAM fabricated coping showed higher fit level at chamfer margin. However, knife margin showed better fitness compared to chamfer margin at MG. AG showed the minimum dimension with a constant result (< $38{\mu}m$).

A Study of the Perception Gap on Nursing Service between Consumers and Providers (간호서비스 질에 대한 소비자와 제공자의 지각차이에 관한 분석)

  • 이미애
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.5
    • /
    • pp.871-884
    • /
    • 2001
  • this study was to investigate the perception gap on nursing service between consumers and providers. Method: the questionnaire founded on the SERVQUAL was developed and distributed to 300 patients and 210 nurses at the three subjected general hospitals in three provincial city, Korea during February to March, 2001. For data analysis, Cronbachs' Alpha, frequency, t-test, and paired t-test were used. Result: 1. In the gap analysis on the 20 properties constituting nursing service, providers almost all perceived higher than consumer in quality. Among them, the number of properties being statistically significant was 7 in the expectation, 18 in the important and 7 in the performance. 2. In the comparison analysis of the perception gap on the expectation-performance and the important-performance, it turned out that the subjected hospitals had to improve their equipment and facilities immediately. It was suggested a good strategy to strengthen the responsiveness factor and the assurance factor of nursing service. Conclusion: it could be concluded that nurses have to recognize the blind spot of their perception and endeavor to take away the perception gap between consumers and providers.

  • PDF

An Experimental Study of 3-D Axial Type Turbine Performance with Various Axial Gaps between the Rotor and Stator (축류형 터빈에서 정${\cdot}$동익 축방향 거리의 변화에 대한 실험적 연구)

  • Kim Jong-Ho;Kim Eun-Jong;Cho Soo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.541-544
    • /
    • 2002
  • The turbine performance test of an axial-type turbine is carried out with various axial gap distances between the stator and rotor. The turbine is operated at the low pressure and speed, and the degree of reaction is 0.373 at the mean radius. The axial-type turbine consists of ons-stage and 3-dimensional blades. The chord length of rotor is 28.2mm and mean diameter of turbine is 257.56mm. The power of turbo-blower for input power is 30kW and mass flow rate is $340m^3/min\;at\;290mmAq$ static-pressure. The RPM and output power are controlled by a dynamometer connected directly to the turbine shaft. The axial gap distances are changed from a quarter to two times of stator axial chord length, and performance curves are obtained with 7 different axial gaps. The efficiency is dropped about $5{\%}$ of its highest value due to the variation of axial gap on the same non-dimensional mass flow rate and RPM, and experimental results show that the optimum axial gap is 1.0-1.5Cx.

  • PDF

An Experimental Study on the CCFL in Narrow Annular Gaps with Large Diameter (곡률 반경이 큰 환상관 간극에서 CCFL에 대한 실험 연구)

  • Lee, Seung-Jin;Jeong, Ji-Hwan;Park, Rae-Joon;Kim, Sang-Baik;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.795-800
    • /
    • 2000
  • A CCFL(Counter Current Flow Limit) test have been performed in narrow annular gaps with large diameter, because it has been confirmed that the CCFL phenomena affected the critical power in hemispherical narrow gap geometries from the SONATA(Simulation Of Naturally Arrested Thermal Attack)-IV (In-Vessel)/VISU(Visualization)-II experiments. The objectives of the CCFL experiments are to investigate the small gap sizes(1, 2mm) effect on CCFL under the large diameter condition and to confirm the findings of the VISU-II study that global dryout in hemispherical narrow gaps was induced by the CCFL. The test section was made of acrylic resin to allow visual observation on the two-phase flow behaviors inside annular gaps. It was observed from visualization that a part of water supplied was accumulated in the upper plenum and a significant increase in the differential pressure across the gap was occurred, which was the definition of the CCFL occurrence in this experimental study. From the experimental results in annular gap with large diameter it can be known that an increase in the differential pressure was not big at small air flow-rates. When the CCFL was occurred, the differential pressure across gaps was increased significantly and a water accumulated in the upper plenum. The occurrence of CCFL was correlated using the Wallis parameter.

  • PDF

An Estimate of the Spark Plug Gap by Measuring Breakdown Voltage (방전전압 측정에 의한 점화플러그의 간극 추정)

  • Jeon, Chang-Sung;Kim, Jung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.210-213
    • /
    • 2005
  • This article describes an estimate method of the spark plug gap by measuring breakdown voltage. Breakdown voltage is the function of spark plug gap, pressure, temperature and humidify. However. It is dominated mainly by the spark plug gap. This technique is applied to in-line process test of the spark plug gap in automobile engine production. Breakdown voltage of normal spark plugs slightly scatters in ordinary conditions and if there is dust or burr in the gap, breakdown voltage gets lower. This technique saves repairing time for bad spark plug and attributes to improve the quality of automobile engine.

  • PDF

Laser Weldability and Formability of Hot Rolled Steels for Hydroforming Applications (하이드로포밍용 열연 강재의 레이저 용접성 및 성형 특성)

  • Lee Won-Beam;Lee Jong-Bong
    • Journal of Welding and Joining
    • /
    • v.22 no.6
    • /
    • pp.19-24
    • /
    • 2004
  • The laser welding and its analysis of thin-sheet carbon steels were carried out with high power $CO_{2}$ laser. The main factor of weld quality of laser welding is gap and edge quality. This work was preformed to focus on the gap tolerance problem during laser welding. First, bead on plate welding of thin sheet was examined to investigate the effect of laser welding variables, and to obtain optimum welding condition. Butt welding was also carried out to show the effect of gap on the laser weldability of thin sheet. In order to investigate the effect of gap on formability of welded thin sheet, LDH test was caried out. At high welding speed, the partial penetration was obtained by low heat input. Otherwise, porosity was formed in the bead at low weld speed because of too much heat input. The optimum welding condition of welding was derived from bead width, penetration and hardness property. The maximum gap tolerance on laser welding was observed to be about 0.2mm. This gap size has good relationship with beam size of laser spot(about 0.3mm). The formability of welded sheet was about $80{\%}$ value of base metal and the gap size has not affected on the formability, although weld quality is dependent on the gap size.

Word Segmentation in Handwritten Korean Text Lines based on GAP Clustering (GAP 군집화에 기반한 필기 한글 단어 분리)

  • Jeong, Seon-Hwa;Kim, Soo-Hyung
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.6
    • /
    • pp.660-667
    • /
    • 2000
  • In this paper, a word segmentation method for handwritten Korean text line images is proposed. The method uses gap information to segment words in line images, where the gap is defined as a white run obtained after vertical projection of line images. Each gap is assigned to one of inter-word gap and inter-character gap based on gap distance. We take up three distance measures which have been proposed for the word segmentation of handwritten English text line images. Then we test three clustering techniques to detect the best combination of gap metrics and classification techniques for Korean text line images. The experiment has been done with 305 text line images extracted manually from live mail pieces. The experimental result demonstrates the superiority of BB(Bounding Box) distance measure and sequential clustering approach, in which the cumulative word segmentation accuracy up to the third hypothesis is 88.52%. Given a line image, the processing time is about 0.05 second.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF