• Title/Summary/Keyword: Gap Sensor

Search Result 403, Processing Time 0.027 seconds

Implementation of Large Area CMOS Image Sensor Module using the Precision Align Inspection (정밀 정렬 검사를 이용한 대면적 CMOS 이미지 센서 모듈 구현)

  • Kim, Byoungwook;Kim, Youngju;Ryu, Cheolwoo;Kim, Jinsoo;Lee, Kyungyong;Kim, Myungsoo;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.8 no.3
    • /
    • pp.147-153
    • /
    • 2014
  • This paper describes a large area CMOS image sensor module Implementation using the precision align inspection program. This work is needed because wafer cutting system does not always have high precision. The program check more than 8 point of sensor edges and align sensors with moving table. The size of a $2{\times}1$ butted CMOS image sensor module which except for the size of PCB is $170mm{\times}170mm$. And the pixel size is $55{\mu}m{\times}55{\mu}m$ and the number of pixels is $3,072{\times}3,072$. The gap between the two CMOS image sensor module was arranged in less than one pixel size.

Electrode Force Characteristics of Micro Servogun (마이크로 서보건의 가압 특성)

  • 임창식;박승규;장희석
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.159-161
    • /
    • 2003
  • Electrode movement signal has been widely used in resistance spot welding system This study is to compare accelerometer signal with gap sensor signal in servo gun system. This study propose that accelerometer output signal is a useful technique of quality monitoring in resistance welding processes.

  • PDF

비즈니스 인사이드 - 프린벨트(주), 인쇄물 자동 검사 시스템 공급 개시

  • Jo, Gap-Jun
    • 프린팅코리아
    • /
    • v.12 no.12
    • /
    • pp.90-92
    • /
    • 2013
  • 프린벨트(주)(대표이사 이근성)는 지난 11월 7일 지산CC 클럽하우스에서 일본 TPE(Tokyo Printing & Equipment Trading Co., Ltd.)가 공급하는 인쇄물 검사 검출 장치 인스펙션 콘트롤 BOTH ${\Sigma}$ SENSOR에 대한 제품설명회 및 국내 첫 도입업체인 (주)올리브디앤피(대표이사 김강천) 견학 행사를 개최했다.

  • PDF

SPATIAL AND TEMPORAL INFLUENCES ON SOIL MOISTURE ESTIMATION

  • Kim, Gwang-seob
    • Water Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.31-44
    • /
    • 2002
  • The effect of diurnal cycle, intermittent visit of observation satellite, sensor installation, partial coverage of remote sensing, heterogeneity of soil properties and precipitation to the soil moisture estimation error were analyzed to present the global sampling strategy of soil moisture. Three models, the theoretical soil moisture model, WGR model proposed Waymire of at. (1984) to generate rainfall, and Turning Band Method to generate two dimensional soil porosity, active soil depth and loss coefficient field were used to construct sufficient two-dimensional soil moisture data based on different scenarios. The sampling error is dominated by sampling interval and design scheme. The effect of heterogeneity of soil properties and rainfall to sampling error is smaller than that of temporal gap and spatial gap. Selecting a small sampling interval can dramatically reduce the sampling error generated by other factors such as heterogeneity of rainfall, soil properties, topography, and climatic conditions. If the annual mean of coverage portion is about 90%, the effect of partial coverage to sampling error can be disregarded. The water retention capacity of fields is very important in the sampling error. The smaller the water retention capacity of the field (small soil porosity and thin active soil depth), the greater the sampling error. These results indicate that the sampling error is very sensitive to water retention capacity. Block random installation gets more accurate data than random installation of soil moisture gages. The Walnut Gulch soil moisture data show that the diurnal variation of soil moisture causes sampling error between 1 and 4 % in daily estimation.

  • PDF

Channel Gap Measurements of Irradiated Plate Fuel and Comparison with Post-Irradiation Plate Thickness

  • James A. Smith;Casey J. Jesse;William A. Hanson;Clark L. Scott;David L. Cottle
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2195-2205
    • /
    • 2023
  • One of the salient nuclear fuel performance parameters for new fuel types under development is changes in fuel thickness. To test the new commercially fabricated U-10Mo monolithic plate-type fuel, an irradiation experiment was designed that consisted of multiple mini-plate capsules distributed within the Advanced Test Reactor (ATR) core, the mini-plate 1 (MP-1) experiment. Each capsule contains eight mini-plates that were either fueled or "dummy" plates. Fuel thickness changes within a fuel assembly can be characterized by measuring the gaps between the plates ultrasonically. The channel gap probe (CGP) system is designed to measure the gaps between the plates and will provide information that supports qualification of U-10Mo monolithic fuel. This study will discuss the design and the results from the use of a custom-designed CGP system for characterizing the gaps between mini-plates within the MP-1 capsules. To ensure accurate and repeatable data, acceptance and calibration procedures have been developed. Unfortunately, there is no "gold" standard measurement to compare to CGP measurements. An effort was made to use plate thickness obtained from post-irradiation measurements to derive channel gap estimates for comparison with the CGP characterization.

Inspection of combination quality for automobile steel balance weight using laser line projector and USB camera (레이저 선 프로젝터와 USB 카메라를 이용한 자동차용 철 밸런스 웨이트의 결합상태 검사)

  • Choi, Kyung Jin;Park, Se Je;Lim, Ho;Park, Chong Kug
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, sensor system and inspection algorithm in order to inspect steel balance weight for automobile is described. Steel balance weight is composed of clip and weight, which is joined by press process. The defective one has a gap between clip and weight. To detect whether there is a gap, sensor system is simply configured with laser line projector and USB camera, which make it possible to measure the height difference of clip and weight area. Laser line pattern which is made on the surface of a balance weight is captured by USB camera. In case that USB camera is used in machine vision, barrel distortion caused by wide angle lens makes the captured image distorted. Image warping function is applied to correct the distortion. Simple image processing algorithm is applied to extract the laser line information and whether it is good or not is judged through the extracted information.

Runout Control of a Magnetically Suspended High Speed Spindle Using Adaptive Feedforward Method (적응 Feedforward를 이용한 자기베어링 고속 주축계의 전기적 런아웃 제어)

  • 노승국;경진호;박종권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.57-63
    • /
    • 2002
  • In this paper, the feedforward control with least mean square (LMS) adaptive algorithm is proposed and examined to reduce rotating error by runout of an active magnetic bearing system. Using eddy-current type gap sensor fur control, the electrical runout caused by non-uniform material properties of sensor target produces rotational error amplified in feedback control loop, so this runout should be eliminated to increase rotating accuracy. The adaptive feedforward controller is designed and examined its tracking and stability performances numerically with established frequency response function. The tested grinding spindle system is manufactured with a 5.5 ㎾ internal motor and 5-axis active magnetic bearing system including 5 eddy current gap sensors which have approximately 15 ~ 30 ${\mu}{\textrm}{m}$ of electrical runout. According to the experimental analysis, the error signal in radial bearings is reduced to less than 5 ${\mu}{\textrm}{m}$ when it is rotating up to 50,000 rpm due to applying the feedforward control for first order harmonic frequency, and vibration of the spindle base is also reduced about same frequency.

Development and Application of System for Pressure Distribution Measurement (압력분포 측정용 시스템 개발 및 응용)

  • 김용환;박성하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.134-140
    • /
    • 2003
  • The film sensor is used for measuring pressure distribution at planar area, especially at a small space or gap. The present paper deals with the development of film type sensors and system for pressure distribution measuring. The developed system is consist of (1)film sensor with 40/sup */40 array, (2)PCI interface card with maximum sampling rate of 100㎐, and (3)software for data processing and real-time display. The contact pressure test of wiper blade and front glass of vehicle was performed with wiper blade by 40cm. Generally spring force of wiper arm is designed at 0.7∼1kN. Test results of total force was 9.4N and 7.1N in each driver and passenger toward. The paper suggested possibility for base definition in wiper design. A windshield wiper blade experiment revealed that the system successfully measured the contact force distribution during static state, showing the usefulness of the developed system.

Implementation of fiber-optic temperature sensor system base on optical absorption device (광흡수 소자를 이용한 광온도 센서 시스템의 구현)

  • 김영수;김요희
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.9
    • /
    • pp.128-134
    • /
    • 1995
  • A fiber-optic temperature sensor utilizing an optical absorption device (InP) was fabricated. The spectrum of transmitted light through an InP device was obtained at the three temperatures(249 K, 369 K). A stabilized LED(light emmiting diode) driver, photoreceiver, and signal proocessing electronics were designed. An intensity referencing technique was adopted in order to minimize the fluctuation of output signal due to external pertubation of the transmitting optical fiber. The optical absorption edge of the InP device moves to longer wavelength at a rate of 0.42 nm / K, and energy gap of InP is 1.35 eV at room temperature. From these results, it is concluded that the InP device has temperature dynamic range of 300 K with LED of center wavelength of 940nm and spectral width of 50nm. The designed fiber-optic temperature sensor system showed good linearity within the temperature range from -30$^{\circ}C$ to + 150$^{\circ}C$.

  • PDF

A Humidity Sensor Using an Electrochemically Prepared Poly(1,5-Diaminonaphthalene)Film

  • Park, Deong-Su;Shim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.241-248
    • /
    • 2003
  • An electrochemical humidity sensor was fabricated with poly(1,5-diaminonaphthalene) film coated on a gap of two splitted gold electrodes, which were made by vacuum deposition. Response currents according to humidity were measured by the potential sweep method and chronoamperometry. The stability of the polymer film was improved by double step chronoamperometry using the applied voltage of ${\pm}0.5$ Vdc. The response time determined by the pulse technique was about ${\sim}50$ msec and the relative standard deviation of current response was within ${\pm}5.0%$. The response current of the film was intrinsically humidity dependent. The film exhibited a non-linear but reproducible response in ordinary range of relative humidity. The linear equations were $I(nA)=0.28{\times}%RH-1.01$ between 10 to 70 %RH and $I(nA)=6.05{\times}%RH-403.21$ between 70 to 90 %RH.