• Title/Summary/Keyword: Gantry Type Machine Center

Search Result 5, Processing Time 0.019 seconds

A Study on Optimization for Static Characteristics Analysis of Gantry-Type Machining Centers (문형머시닝센터의 구조해석을 통한 최적화에 관한 연구)

  • Yoo, Deck-Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.122-128
    • /
    • 2015
  • Recently, as the demand for high efficiency, multi-function machine tools has increased, domestic machine tool industries are investing in research and development for Gantry-Type Machining centers. In this thesis, for the purpose of evaluating machining accuracy and designing a machine tool structure, a simplified model of the main frame is suggested. The results show the general characteristics of the optimum design, and the approach is shown as practicable for the preliminary design analysis and improvement of a conceptual design of a Gantry-Type Machining center. This paper's results are expected to improve the static characteristics of Gantry-Type Machine centers. The three-dimensional finite element models proved that the modeling method might be applied to real machine tool structures.

Development of a Geometric Error Analysis and Virtual Manufacturing System for Gantry-Type 5-Axis Machining Centers (문형 5축 머시닝센터의 기하학적 오차해석 및 가상가공 시스템 개발)

  • 윤태선;조재완;김석일;곽병만
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.172-179
    • /
    • 1998
  • To quickly determine the effect of the substitute component on the machine's performance is very important in the design and manufacturing processes. And minimizing machine cost and maximizing machine quality mandate predictability of machine accuracy. In this study, in order to evaluate the effects of the component's geometric errors and dimensions on the machining accuracy of gantry-type 5-axis machining centers, a geometric error analysis and virtual manufacturing system are developed based on the mathematical model for the shape generation motion of machine tool considering the component's geometric errors and dimensions, the solid modeling techniques and so on.

  • PDF

문형 5축 머시닝센터의 기하학적 오차해석 및 가상가공 시스템 개발

  • 윤태선;조재완;곽병만
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.830-835
    • /
    • 1995
  • To quickly determine the effect of the substitute component on the machine's performance is very important in the defign and the manufacturing processes. And minimizing machine cost and maximizing machine quality mandata predictability of machine accuracy. In the study, in order to evaluate the effects of the component's geometric errors and dimensions on the machining accuracy of gantry-type 5-axis machining centers, a geometric error analysis and virtual manufacturing system is developed based on the mathematical model for the shape generation motion of machine tool considering the component's geometric errors and dimensions, the solid modeling techniques and so on.

  • PDF

Design Technology of High Speed and Precision Machining Center (초곡속 고정밀 머시닝 센터 설계 기술)

  • Kim, Bup-Min;Choi, Won-Sun;Ha, Jae-Young;Kim, Tae-Hyoung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.869-877
    • /
    • 2011
  • In order to manufacture precision parts which are used for IT and BT Industry by machining, users need higher speed & precision machining center. So, for development of this kind of machine, we designed gantry type machining center which is piling of 3 axes on one moving body and the 2-axis rotary table is fixed on the base. It is applied linear motor that is instead of ball-screw and servo-motor combination and 50,000 rpm high-speed spindle. Composite material structure called mineral casting or resin concrete is applied also. This paper presents design technology and evaluated results of high speed and precision machining center.

A Study on the Neutron in Radiation Treatment System and Related Facility (방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구)

  • Kim Dae-Sup;Kim Jeong-Man;Lee Hee-Seok;Lim Ra-Seung;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • Purpose : It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the spacial effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. Materials and Methods : The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to $15{\times}15cm^2$. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. Results : The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Conclusion : Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.

  • PDF