• Title/Summary/Keyword: Gamma-rays

Search Result 587, Processing Time 0.043 seconds

Development of a Portable Detection System for Simultaneous Measurements of Neutrons and Gamma Rays (중성자선과 감마선 동시측정이 가능한 휴대용 계측시스템 개발에 관한 연구)

  • Kim, Hui-Gyeong;Hong, Yong-Ho;Jung, Young-Seok;Kim, Jae-Hyun;Park, Sooyeun
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.481-487
    • /
    • 2020
  • Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

SEPARATION OF GAMMA-RAYS PRODUCTION FROM $^{13}C(p,\;{\gamma})^{14}N,\;^{14}N({\gamma},\;{\gamma})^{14}N$ REACTIONS USING DOPPLER SHIFT EFFECT

  • Kim, Y.K.;Ha, J.H.;Youn, M.;Han, S.H.;Chung, C.E.;Moon, B.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.287-290
    • /
    • 2001
  • The 9.17MeV gamma-rays from the $^{13}C(p,\;{\gamma})^{14}N,\;^{14}N({\gamma},\;{\gamma})^{14}N$ reactions were measured. The incident 9.17MeV gamma-ray was produced from the $^{13}C(p,\;{\gamma})^{14}N$ reaction at Ep=1.75MeV resonance. The 1.75MeV proton beam was accelerated using the 3MV SNU-AMS Tandetron and 1.7MV KIGAM Tandem accelerators. The enriched 13C target was $121{\mu}g/cm^2$ self-supporting foil, and we used liquid nitrogen as a resonant absorption target. We used a HP-Ge detector with 30% efficiency and less 2keV energy resolution. We developed new method to detect the scattered 9.17MeV gamma-ray from the nitrogen target by using the energy difference between the Doppler shifted gamma-ray from the $^{13}C(p,\;{\gamma})^{14}N$ reaction and the resonant absorbed and rescattered gamma-ray from the $^{14}N({\gamma},\;{\gamma})^{14}N$ reaction.

  • PDF

Radiation Treatment of Terephthalic Acid and Ethylene Glycol by using Gamma-rays (감마선을 이용한 테레프탈산과 에틸렌글리콜의 방사선처리)

  • Lee, Sun-Mi;Jo, Hun-Je;Kim, Jeong-Gyu;Jung, Jinho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.452-456
    • /
    • 2004
  • Gamma-rays effectively decomposed TPA and EG, thus removal of $1.0{\times}10^{-3}$ M pollutants was near 65 and 95%, respectively, at an absorbed dose of 10 kGy. However, TOC removal in the radiation treatment was less than 5% due to a low transformation of both TPA and EG to $CO_2$. For TPA, gamma-ray treatment largely reduced biodegradability($BOD_5/COD$) by degrading TPA to non-biodegradable organic acids. This implies that the change of biodegradability should be considered when the radiation treatment is combined with conventional biological techniques. A weight-loss wastewater containing TPA and EG was also purified by gamma-ray treatment. Extraordinarily, biodegradability of the wastewater was increased at a low dose of 1 kGy. Though underlying mechanism was not clearly identified, this result stresses the effect of wastewater composition and absorbed dose on the biodegradability change.

PROTECTION OF DNA BY SCUTELLARlA BAICALENSIS IN HL-60 CELLS EXPOSED TO $\gamma$-RAYS; ANALYSED BY MICRONUCLEI FORMATION AND SINGLE CELL GELL ELECTROPHORESIS

  • Heon Oh;Park, Hae-Ran;Ham, Yeon-Ho;Kim, Sung-Ho;Jo, Sung-Kee
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.107-107
    • /
    • 2001
  • In the present study, the protective effect of Scutellaria baicalensis against DNA damage in HL-60 cells exposed to $^{60}$ Co ${\gamma}$-rays was evaluated using micronuclei formation and alkaline single cell gel electrophoresis (SCGE, comet assay). The frequency of micronuclei was decreased in groups treated with water extract (P<0.01), polysaccaride fraction (P<0.01) and methanol fraction (P<0.01) before/after exposure to 200 cGy of ${\gamma}$-rays.(omitted)

  • PDF

The Development of Beam Profiling System for the Analysis of Pulsed Gamma-ray Using the Electron Accelerator (전자빔가속기를 이용한 펄스감마선 출력특성 분석용 빔프로파일링 장치개발)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2410-2416
    • /
    • 2016
  • Recently, most countries in the world have pursued a denuclearization. So it has been of interest to increase to Nuclear weapon in such as North Korea's continued nuclear test. Pulsed gamma rays produced in the nuclear explosion and the space environment can give the big damage to the electronic device in a very short period of time. To confirm the extent of damage of these electronic devices, pulsed gamma irradiation facility that can occur in nuclear weapon or space environment are required. In this paper, we implemented the pulsed gamma-ray detection module and analyzed output of the irradiation test. We have experimented using an electron beam accelerator research facilities in Pohang Accelerator similar conditions to equip and Nuclear weapon. As a result, we confirmed that the pulsed gamma rays emitted by the gamma radiation and electron beam conversion device. The results of this paper will contribute to improve the reliability and accuracy of studies for utilizing pulsed gamma rays.

GAMMA-RAY EMISSION FROM BLAZARS

  • TAKAHARA FUMIO
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.99-102
    • /
    • 1996
  • I discuss implications of gamma-ray emission from blazars based on electron acceleration by shock waves in a relativistic jet. The number spectrum of electrons turns out to be a broken power law; while at low energies the power law index has a universal value of 2, at high energies it steepens to an index of 3 because of strong radiative cooling. This spectrum can basically reproduce the observed spectral break between X-rays and gamma-rays. I show that energetics of relativistic jets can be well explained by this model. I estimate physical quantities of the relativistic jets by comparing the prediction with observations. The results show that the jets are particle dominated and are comprised of electron-positron pairs. A connection between gamma-ray emission and radiation drag is also discussed.

  • PDF

Gene Expression of Glutathione Peroxidase in $Saccharomyces$ $cerevisiae$ Treated with $N$-acetyl-L-cysteine and Gamma-rays ($Saccharomyces$ $cerevisiae$에서 $N$-acetyl-L-cysteine 처리와 감마선 조사에 따른 Glutathione Peroxidase 유전자 발현)

  • Park, Ji-Young;Baek, Dong-Won;Nili, Mohammad;Kim, Jin-Kyu
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.4
    • /
    • pp.258-264
    • /
    • 2011
  • Glutathione (GSH) has important roles in cellular defense against oxidative stress, 1) direct scavenging of reactive oxygen species (ROS), and 2) coenzyme of ROS scavenging enzyme like glutathione peroxidases (GPx). GSH peroxidase reduces free hydrogen peroxide to water using 2GSH. $N$-acetyl-L-cysteine (NAC), one of the antioxidants, is used as a precursor for intracellular GSH. In this study, relation of GSH, NAC, and GSH peroxidase was investigated through transcriptional expression of $GPX1$ and $GPX2$, which are GSH peroxidase encoding genes, in yeast cells treated with 0 mM to 20 mM of NAC or in combination with 100 Gy gamma-rays. The transcriptional expression of $GPX1$ and $GPX2$ was induced by NAC and 100 Gy gamma-rays. The gene expression of both GSH peroxidases was decreased with increasing concentrations of NAC in irradiated yeast cells. These results suggest that elevation of intracellular GSH by NAC and oxidative stress and ROS generated from gamma-rays induces expression of GSH peroxidase genes, and that NAC can protect the yeast cells against ROS generated from gamma-rays through direct scavenging of ROS and transcriptional activation of GSH peroxidase.

Sensitivity of Lavender to Proton, Electron, and Gamma Radiation

  • Chen, Wensheng;Li, Hui;Shi, Lei;Bai, Hong Tong
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.122-133
    • /
    • 2016
  • While ion beams are widely used in plant breeding, little is known about the sensitivity of Lavandula angustifolia (lavender) to ionizing radiation. To compare the biological effects of different types of ionizing radiation on the germination and survival rates of lavender, we exposed lavender seeds to gamma rays, 3 MeV electron beams, and 1.89 MeV proton ion beams. We observed that the seed germination rate decreased with increasing dosages of all three types of ionizing radiation. The malformation rate of lavender seedlings exposed to electron beams and gamma rays increased with increasing radiation dosage. By contrast, the effect of the accelerated proton beams on the malformation rate was negatively correlated with the dosage used. The survival rate of lavender seedlings exposed to the three types of ionizing radiation decreased in a dose-dependent manner. In addition, the survival rate of seedlings irradiated with proton and electron beams decreased more slowly than did that of seedlings irradiated with gamma rays. The half-lethal dose of gamma rays, electron beams, and proton beams was determined to be 48.1 Gy, 134.3 Gy, and 277.8 Gy, respectively, and the most suitable proton-ion energy for lavender seeds in terms of penetration depth was determined to be 5 MeV. These findings provide valuable information for the breeding of lavender by radiation mutation.

GPS QUASARS AS SPECIAL BLAZARS

  • BAI J. M.;LEE MYUNG GYONG
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.125-128
    • /
    • 2005
  • In this paper, we argue that the gigahertz peaked spectrum (GPS) quasars are special blazars, blazars in dense and dusty gas enviornment. The ROSAT detection rate of GPS quasars is similar to that of flat spectrum radio quasars (FSRQs), suggesting that the relativistic jets in GPS quasars are oriented at small angle to the line of sight. Due to strong inverse Compton scattering off infrared photons from dense and dusty nuclear interstellar media in GPS quasars, most of them may have significant soft gamma-ray and X-ray emission, which is consistent with ASCA X-ray observations. Because Compton cooling in GPS quasars is stronger than that in FSRQs, synchrotron emission in GPS quasars may less dominate over thermal emission of the accretion disk and hot dust, hence most GPS quasars show low optical polarization and small variability, consistent with observations. We suggest that it is the significant radio emission of electron/positron pairs produced by the interaction of gamma-rays with the dense gas and dust grains in GPS quasars that makes GPS quasars show steep radio spectra, low radio polarization, and relatively faint VLBI/VLBA cores. Whether GPS quasars are special blazars can be tested by gamma-ray observations with GLAST in the near future, with the detection rate of GPS quasars being similar to that of FSRQs.

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700 (단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가)

  • Kim, Sunghwan;Cheon, Jongkyu;Lee, Jae Jin;Nam, Uk-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.