• Title/Summary/Keyword: Gamma-ray Processing

Search Result 69, Processing Time 0.198 seconds

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF

Effects of Electron Beam Irradiation on the Quality of Kochujang Powder (Electron Beam 조사가 고추장 분말의 품질에 미치는 영향)

  • Kwon, Hoon;Lee, Jung-Eun;Kim, Jeong-Sook;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.4
    • /
    • pp.655-662
    • /
    • 2000
  • Electron beam (EB) irradiation was applied to study microbial decontamination effects for kochujang powder by determining their microbiological and physicochemical qualities over gamma ray (GR) irradiation. The samples showed a high microbial population, such as 105~106 CFU/g of total aerobic bacteria, negative of yeasts & molds and coliforms. Total bacterial counts were decreased by 1~2 log cycles with EB irradiation at 5~7.5 kGy, and 10 kGy irradiation was enough to improve the microbiological quality by reducing populations to below 104CFU/g, which was similar to gamma energy. Such doses were effective for controlling the microbial growth in stored samples during storage for 4 months at room temperature. Decimal reduction doses (D10 value) on initial bacterial populations were 2.88~3.02 kGy in EB and 3.57~3.59 kGy in GR, which were influenced by initial populations and energy types applied. Based upon the above results, 7.5~10 kGy irradiation caused negligible changes in Hunter's color, capsaicin, fatty acid composition and organoleptic qualities. Considering the quality changes resulting from subsequent storage, such as a decrease in capsanthin content and an increase in TBA value in the samples, it is recommendable to irradiate kochujang powder at 7.5~10 kGy when used for food processing.

  • PDF

A Study on the Preparation of Aluina & Titania Sols for Coatings (코팅용 알루미타, 티타니아솔 제조에 관한 연구)

  • Kim, Chu-Hui;Choe, Hyeong-Su;Jo, Yeong-Sang;Im, Jong-Ju
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.319-328
    • /
    • 1994
  • Aluminium and titanium precursors containing $\beta$-diketonate ligands were used for the synthesis of polymeric sols of alumina and titania by sol-gel methods. To prepare polymeric sols by solgel processing, we synthesized modified precursors having chelating organic ligands. With these precursors it was found to be possible to control both hydrolysis and polycondensation reaction rates which resulted in ultrafine particles few nms of average size. The optimum molar ratio of acid to alkoxide for alumina sol was 0.3-0.4 and that of water to alkoxide &as 1. On the other hand, the corresponding ratios for titania sol were found be 0.25-0.20 and 1 respectively. Dynamic light scattering measurements indicated that the average particle size in both sols was in the order of few nms. SEM photographs were taken to observe crack-free and smooth surfaces of coated membranes after sintering at $450^{\circ}C$. Alumina coated membrane on a slide glass had about 4-4.5$\mu \textrm{m}$, thickness and titania coated one had 2-2.5$\mu \textrm{m}$, thickness. And according to TEM photographs, the grain size of titania was smaller than 30nm and that of alumina was in the range of few $\AA$s to 2nms. An X-ray diffraction study revealed that alumina was $\gamma$ phase and titania was anatase crystal.

  • PDF

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Impacts of Irradiation Sources on Quality Attributes of Low-salt Sausage during Refrigerated Storage

  • Song, Dong-Heon;Kim, Hyun-Wook;Hwang, Ko-Eun;Kim, Yong-Jae;Ham, Youn-Kyung;Choi, Yun-Sang;Shin, Dong-Jin;Kim, Tae-Kyung;Lee, Jae Hoon;Kim, Cheon-Jei;Paik, Hyun-Dong
    • Food Science of Animal Resources
    • /
    • v.37 no.5
    • /
    • pp.698-707
    • /
    • 2017
  • This study was performed to investigate the impacts of irradiation sources on quality attributes of low-salt sausage during refrigerated storage. Control sausage was prepared with 1.5% sodium chloride (NaCl), whereas low-salt sausage was formulated with 0.75% NaCl (a 50% reduction; L-control). Sausage samples were vacuum-packaged, and low-sausages were irradiated with gamma-ray, electron-beam and X-ray at 5 kGy, respectively. The samples were stored at $4^{\circ}C$ for 28 d to determine changes in quality attributes. The pH of low-salt sausages was unaffected by irradiation at 5 kGy (p>0.05). Higher redness values were found at irradiated low-salt sausages compared to control (p<0.05). The hardness, gumminess and chewiness of control sausage were higher than those of low-salt sausages (p<0.05). However, there were no significant differences in the textural parameters between low-salt sausage treatments. The overall sensory acceptability score of irradiated/low-salt sausages were lower than L-control due to decreased scores for cooked meat flavor but increased radiolytic off-flavor (p<0.05). The initial 2-thiobarbituric acid-reactive substances (TBARS) values of irradiated/low-salt sausages were higher than control and L-control (p<0.05). However, the TBARS values of irradiated treatments were significantly lower than control at the end of storage. Irradiation could effectively inhibit the microorganism growth (total aerobic bacteria, coliforms, Enterobacteriaceae, and Pseudomonas spp.) in low-salt sausages (p<0.05). Therefore, our findings show that irradiation could be to improve microbial safety of low-salt sausages, and suggest that further studies should be necessary to reducing radiolytic off-flavor of irradiated/low-salt sausages.

Shelf life of Bottled Sea Squirt Halocynthia roretzi Meat Packed in Vegetable Oil (BSMO)

  • Choi, Nam-Do;Zeng, Jiting;Choi, Byung-Dae;Ryu, Hong-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.37-46
    • /
    • 2014
  • Fresh sea squirt meat requires a modified processing and preservation process because it has a short shelf life due to its high moisture content and strong proteolytic enzyme activity. In this study, bottled sea squirt meat prepared in vegetable oil (BSMO) to enhance the consumer acceptability was exposed to ${\gamma}$-ray (Co60, 10 kGy/h) irradiation to extend the shelf life without the use of a heating process. Response surface methodology was used to determine the optimal mixing ratio of BSMO containing 5% dehydrated fresh meat. Texture analysis and nutritional evaluation were also performed on a control and BSMO samples. The volatile basic nitrogen (VBN) content and total cell count were measured to determine the shelf life of irradiated BSMO products during chilled storage at $4^{\circ}C$ for 60 days. According to a panel of 10 trained tasters (aged 20-29 years), the optimal mixing formulation was 80 g meat in 60 mL of mixed vegetable oil (30 mL of olive oil and 30 mL of sesame oil). The highest rated formulation, according to a panel of nine trained tasters (aged ${\geq}30$ years), was 80 g meat in 60 mL of mixed vegetable oil (42 mL of olive oil and 18 mL of sesame oil). Moisture, ash, and protein contents in BSMO did not change significantly (P < 0.05) compared with the control. A higher lipid content ($0.84{\pm}0.23$ to $2.13{\pm}0.61$; P < 0.05) was observed due to the presence of vegetable oil on the surface of BSMO. The vegetable oil raised the hardness, springiness, cohesiveness, gumminess, chewiness, and resilience of BSMO. BSMO products remained edible after 50 days of storage at $4^{\circ}C$ based on the VBN content (BSMO 1: $27.92{\pm}0.96$ mg/100 g, BSMO 2: $24.84{\pm}1.95$ mg/100 g) and total cell count (BSMO 1: $4.60{\pm}0.80$ log CFU/mL, BSMO 2: $3.65{\pm}0.20$ log CFU/mL) when compared with standard levels of VBN (25.00 mg/100 g) and total cell count (5 log CFU/mL), respectively. The results showed that irradiated BSMO products could help to expand the processed seafood market and increase the popularity of seafood among the younger generations.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.