• Title/Summary/Keyword: Gamma-ray Probe

Search Result 9, Processing Time 0.028 seconds

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy (LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발)

  • Han, Ki-Tek;Yoo, Wook-Jae;Shin, Sang-Hun;Jeon, Da-Yeong;Park, Jang-Yeon;Park, Byung-Gi;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.

Feasibility Study on Development of a Fiber-Optic Dual Detector to Measure Beta- and Gamma-rays Simultaneously (베타/감마 동시 측정용 광섬유 이중 검출기의 개발을 위한 기초연구)

  • Hong, Seunghan;Shin, Sang Hun;Sim, Hyeok In;Kim, Seon Geun;Jeon, Hyesu;Jang, Jaeseok;Kim, Jaeseok;Kwon, Guwon;Jang, Kyoung Won;Yoo, Wook Jae;Lee, Bongsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.284-290
    • /
    • 2014
  • A fiber-optic beta/gamma dual detector system with two types of sensing probes was fabricated to detect the beta- and gamma-rays simultaneously. As scintillators of the sensing probe type 1, two different inorganic scintillators, $CaF_2(Eu)$ and LYSO(Ce) crystals, were used to obtain the each scintillating efficiency with respect to beta-and gamma-rays and the inherent energy spectra of radioactive isotopes. In the case of the sensing probe type 2, which is composed of two identical inorganic scintillators and a beta shielding material based on the lead, it could discriminate beta- and gamma-rays using a subtraction method. In conclusion, we demonstrated that the proposed fiber-optic beta/gamma dual detector could measure and discriminate beta- and gamma-rays using both energy spectroscopy and subtraction method.

Study on the Geophysical Research Applications Using Radioactive Isotopes (I) Study on the Structures in Strata by Using γ-γ Logging Apparatus (방사성동위원소의 지구물리학적 응용에 관한 연구 γ-γ 검층법에 의한 지층구조에 관한연구)

  • Lee, Hyun Duk;Rho, Seung Gy
    • Economic and Environmental Geology
    • /
    • v.9 no.3
    • /
    • pp.135-141
    • /
    • 1976
  • The gamma-gamma logging method appplying in geophysical research are presented in this paper_ The logging probe assembly was designed which permits changing the source-to-detector spacing while conditions of proceeding ${\gamma}-{\gamma}$ logging, which a collimated gamma ray source ($^{60}Co$, 0.5mCi and/or 2 mCi) is separated from the scintillation detector as shown in Fig. 2 and 3, size is 6.0 cm in diameter and 120.0 cm in long and the exposed parts are made of stainless steel pipe. The results is confirmed by the experiment performed mainly in granite rock where a slightly constant shape was obtained but sometimes was shown sharpness shape for the measured scattered gamma-ray intensity. Consequently, the experimental results are obtained an adequate intensity of scattered gamma-rays and favourable response to density change, and also very closely correspond to between core samples of the test boring and to used this method of ${\gamma}-{\gamma}$ logging in the test bore-hole of the strata.

  • PDF

Ultra-Fast Flash Observatory (UFFO) for early photon measurements from Gamma Ray Bursts

  • Park, Il H.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.66-66
    • /
    • 2012
  • We describe the space project of Ultra-Fast Flash Observatory (UFFO), which will observe early optical photons from gamma-ray bursts (GRBs) with a sub-second optical response, for the first time. The UFFO will probe the early optical rise of GRBs, opening a completely new frontier in GRB and transient studies, using a fast-response rotatable mirror system which redirects opitical path to telescope instead of slewing of telescopes or spacecraft. In our small UFFO-Pathfinder experiment, scheduled to launch aboard the Lomonosov satellite in June 2012, we use a motorized mirror in our Slewing Mirror Telescope instrument to achieve less than one second optical response after X-ray trigger. We describe the science and the mission of the UFFO project, including a serious version called UFFO-100 which will be launched in 2014. With our program of ultra-fast optical response GRB observatories, we aim to gain a deeper understanding of GRB mechanisms, and potentially open up the z>10 universe to study via GRB as point source emission probes.

  • PDF

Design and Experiment on the Portable Gamma-Ray Pipe Thickness Gauge (휴대용 감마선파이프측후도의 설계와 시작)

  • 김덕진;김홍식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.2
    • /
    • pp.3-15
    • /
    • 1967
  • In the design of a portable Gamma-ray transistorized steel pipe thickness gauge, a pulse height discriminator and an anti-coincidence circuit could be eliminated by using a thin, less than 1/2inch, NaI(Tl) scintillation crystal in the detecting probe. This method could provide an economic design and fabrication of a gamma-ray back-scattering gauge allowing allmost the same accuracy and stability compared with the exsisting method. A gauge had been designed and fabricated with the above method and its accuracy was experimentall tested for the 200$^{\circ}C$ high temperature steel pipes. The result showed that the thermal drift was less than y percent which was acceptabel in the practical applications.

  • PDF

Steel Plate Thickness Gauge by means of Gamma-Ray Backscattering (감마선 빽스켓터링을 이용한 철판 두께 측정에 관하여)

  • 김덕진;김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.1
    • /
    • pp.18-23
    • /
    • 1966
  • An experimental study of a steel plate thickness gauge by means of the measurements of backscatered gamma-rays has been carried out. The difference between this and other methods is that this method does not include any shilding matterials in the detecting probe, because the primary radiations and the backscattered radiations are detected simultaneously by an NaI (TI) scintillating crystal, and the activity of the Co-60 source used is low enough. In this thickness gauge, the thickness of the steel plates can be read directly on the counting ratemeter scale. The optimum conditions in the source-to-detector distance, window width of the analyzer, energy and strength of the gamma-ray source were found experimentally. The results have shown that the accuracy of the gauge was about $\pm$3% in the range of 3 to 8mm thickness. This gauge can be used to detect the pits or corrosions on the inner walls of the steel pipes.

  • PDF

Phase Change Characteristics of Sb-Based Phase Change Materials

  • Park, Sung-Jin;Kim, In-Soo;Kim, Sang-Kyun;Choi, Se-Young
    • Korean Journal of Materials Research
    • /
    • v.18 no.2
    • /
    • pp.61-64
    • /
    • 2008
  • Electrical optical switching and structural transformation of $Ge_{15}Sb_{85}$, $Sb_{65}Se_{35}$ and N2.0 sccm doped $Sb_{83}Si_{17}$ were studied to investigate the phase change characteristics for PRAM application. Sb-based materials were deposited by a RF magnetron co-sputtering system and the phase change characteristics were analyzed using an X-ray diffractometer (XRD), a static tester and a four-point probe. Doping Ge, Se or Si atoms reinforced the amorphous stability of the Sb-based materials, which affected the switching characteristics. The crystallization temperature of the Sb-based materials increased as the concentration of the Ge, Se or Si increased. The minimum time of $Ge_{15}Sb_{85}$, $Sb_{65}Se_{35}$ and N2.0 sccm doped $Sb_{83}Si_{17}$ for crystallization was 120, 50 and 90 ns at 12 mW, respectively. $Sb_{65}Se_{35}$ was crystallized at $170^{\circ}C$. In addition, the difference in the sheet resistances between amorphous and crystalline states was higher than $10^4{\Omega}/{\gamma}$.