• Title/Summary/Keyword: Gamma-radiation

Search Result 2,216, Processing Time 0.029 seconds

Effects of Gamma-irradiation on Anti-diabetic and Cytotoxic Activities of Heat-treated Mistletoe (Viscum album) (감마선 조사가 열처리 겨우살이의 항당뇨 및 세포독성에 미치는 영향)

  • Park, Jong-Heum;Kim, Su-Min;Sung, Nak-Yun;Song, Du-Sup;Byun, Eui-Baek;Kim, Jae-Kyung;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.183-190
    • /
    • 2013
  • Mistletoe (Viscum album) has been widely used as a functional food material for various therapeutic purposes from ancient time. In this study, we examined anti-diabetic and cytotoxic activities of heated-treated mistletoe and the effects of gamma-irradiation on its activities. Heat-treated mistletoe extract was prepared by heating during different time (3, 6, 9 and 12 h) and gamma-irradiated with different doses of 0, 10, 30, 50, 70 and 100 kGy. Heat-treated mistletoe extracts showed a concentration-dependent cytotoxicity on rat insulinoma RINm5F cells and the effect was gradually decreased as heating time increased up to 12 h. 12 h heat-treated extract was no cytotoxic. Gamma-irradiation enhanced the reduction of heat-treated mistletoe-induced cytotoxicity and the decreasing effect was an irradiating dose-dependent. In particular, all of 70 kGy irradiated and heat-treated mistletoe extracts did not showed the cytotoxicity and the effect was comparable to 12 h heat-treated mistletoe extract. Among those extracts, 3 h heat-treated mistletoe extract gradually increased the insulin secreting activity by gamma-irradiation and the effect was the best at 70 kGy, whereas 12 heat-treated extract was no effect. On the test of ${\alpha}$-glucosidase inhibitory activity, 3 h heat-treated mistletoe extract showed the concentration dependent effects and gamma-irradiation induced more activity at 70 kGy, compared to non-irradiated 3 h and 12 h heated mistletoe extracts. These results suggest that the combination of heat treatment and gamma-irradiation might be more effective than only heat-treatment for improving the anti-diabetic activity of mistletoe extract and reducing its cytotoxicity.

The Effect of Gamma ray irradiation on Paper Properties (감마선 조사처리가 지류의 물성에 미치는 영향)

  • Jeong, Hye-Young;Choi, Kyoung-Hwa;Park, Ji-Hee;Jung, Pil-Mun;Choi, Jong-Il
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.3
    • /
    • pp.43-49
    • /
    • 2010
  • Recently, the use of fumigants for pest control of paper cultural heritages are limited because of the high toxicity of fumigants and the production of environment-harmfully compounds. Therefore, many non-chemical methods have been discussed and experimented. And it is recently focused on gamma radiation, which is one of non-chemical methods, for pest control of paper cultural heritage in Korea. In this paper, we carried out a gamma ray irradiation of papers including Hanji, copy paper, filter paper and then analyzed a physical properties and optical properties of paper sample to estimate the effect of gamma ray irradiation on paper properties. In result, gamma radiation have adverse effect on a physical properties and optical properties of paper, especially Hanji. Therefore, we have to carefully consider about using of gamma ray for pest control of paper cultural heritages.

Effect of Gamma Knife Surgery for Uveal Melanoma (Uveal Melanoma에 대한 Gamma Knife Radiosurgery의 효과)

  • Kim, Gi-Hong;Cho, Jung-Hee;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.50-55
    • /
    • 1997
  • The optimal management of uveal melanoma is still a matter of controversy. To determine the effect of Gamma Knife surgery for patients with uveal malanoma. the authors reviewed the results of 5 patients underwent Gamma Knife sugery between Sep. 1993 and Dec. 1996. The mean age was 60.7 years ranging from 42.5 to 76.5 years. Median follow-up was 13.29 months and the patient with follow up period more than 6 months was 4. The mean tumor volume was $3442 mm^3$(mean diameter 15.3 mm) and all patients were irradiated with a mean maximum dose of 74Gy(range $60\~80\;Gy$), using the $50\%$ isodose. After Gamma Knife surgery. one pateint showed complete disapperance in tumor size with follow-up 32 months, one enucleation due to progression, and 2 no interval change. In regard to vision, one patient blind. one enucleation, and 2 patients had no interval change. According to our experiences, Gamma Knife surgery for uveal melanoma be able to achieve local tumor control, spare the eyeball, and have possibility of save vision.

  • PDF

Ginsan Improved Th1 Immune Response Inhibited by Gamma Radiation

  • Han Seon Kyu;Song Jie Young;Yun Yeon Sook;Yi Seh Yoon
    • Archives of Pharmacal Research
    • /
    • v.28 no.3
    • /
    • pp.343-350
    • /
    • 2005
  • Gamma radiation causes suppression of the immune function, and immune properties are related to cytokine production. In the present study, the polysaccharide, Ginsan, purified from an ethanol-insoluble fraction of Ginseng (Panax ginseng C.A. Meyer, Araliaceae) water extract was studied to assess its effects on the immunosuppressive activities of gamma radiation. Gin­san was found to stimulate murine normal splenocytes by inducing the mRNA expressions of Th1 and Th2 type cytokines, and also restore the mRNA expression of IFN-$/gamma$, Th1 cytokine, after its inhibition by whole-body gamma irradiation. Therefore, Ginsan was found to restore the T lymphocytes function that had been suppressed by gamma irradiation in allogenic MLR (mixed lymphocyte reactions). However, Ginsan exhibited no excessive stimulatory effects on the control group. The above results indicated that Ginsan may constitute a new noble agent for the improvement of gamma radiation-induced immunosuppression.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

Decomposition of Acetylsalicylic Acid by Gamma Ray (감마선 조사에 의한 Acetylsalicylic Acid의 분해)

  • Ahn, Young Deok;Lee, Kyoung-hwon;Lee, O Mi;Kim, Tae-Hun;Jung, In ha;Yu, SeungHo;Lee, Myun-Joo
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.253-258
    • /
    • 2011
  • Acetylsalicylic acid (ASA) has been issued recently in contaminated water environments because of potential impacts on ecosystem and public health. This study was aimed at investigating the possibility of ASA degradation using gamma ray irradiation. In addition, the use of sodium persulfate, hydrogen peroxide, ferrous sulfate were tested in order to examine a synergistic effect with gamma ray. The absorbed dose was ranged from 0.2 to 10 kGy and the concentration of oxidants were from 0.1 to 10 mM in this study. The concentration of ASA was gradually decreased corresponding to the increase of the absorbed dose. When soudium persulfate was simultaneously applied, most of the parent compound was completely degraded even at a low dose of 0.8 kGy. The removal efficiency of total organic carbon was 90% even at the highest dose of 10 kGy without sodium persulfate. However, the efficiency was dramatically enhanced up to 98% at the same dose by adding 10 mM of oxidants. It was suggested that hydroxyl radical ($OH{\cdot}$) and sulfate radical ($SO{_4}^-{\cdot}$) were formed in the system and made roles in degrading ASA at the same time.

Effects of Low Dose $\gamma$-Radiation on the Growth, Activities of Enzymes and Photosynthetic Activities of Gourd (Lagenaria siceraria) (저선량 $\gamma$선 조사가 참박의 초기 생육과 효소 활성 및 광합성 능에 미치는 영향)

  • 이혜연;김재성;백명화;이영근;임돈순
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.3
    • /
    • pp.197-204
    • /
    • 2002
  • Gourd seeds were irradiated with the doses of 0-20 Gy to investigate the effect of the low dose $\gamma$-radiation on the early growth and physiological activity. The stimulating effects of the low dose y- radiation on the early growth were not noticeably high, but were increased generally at 4-16 Gy irradiation group. The catalase and peroxidase activity of cotyledon from seeds irradiated with $\gamma$- radiation were increased at 8 Gy irradiation group. The photochemical activity of leaf was noticeably high at 4 Gy irradiation group. The photochemical yield of PSII, estimated as Fv/Fm, decreased with increasing illumination time by 50% after 4 hrs in the control and 8 Gy irradiation group, while Fo slightly increased. However, Fv/Em in the 4 Gy irradiation group decreased by 40% of inhibition, indicating that photoinhibition decreased by the low dose $\gamma$- radiation. Changes in the effective quantum yield of PSII, $\varphi_{PSII}$ and 1/Fo- l/Fm, a measure of the rate constant of excitation trapping by the PSII reaction center, showed similar pattern to Fv/Em. NPQ decreased by 70% after photoinhibitory treatment with showing similar pattern between the control and the irradiation group. These results showed the positive effect of low dose $\gamma$- radiation on the seedling growth and the reduction of photoinhibition in the 4 Gy irradiation group.

Crosslinking of Electrospun Poly (VDF-co-HFP) Nanofibrous Membranes by Gamma-ray Irradiation

  • Kim, Yun-Hye;Lim, Youn-Mook;Choi, Jae-Hak;An, Sung-Jun;Park, Jong-Seok;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.105-110
    • /
    • 2008
  • Poly (VDF-co-HFP)/PEGDMA nanofibrous membranes (NFMs) have been prepared by an electrospinning process. Since electrospun NFMs have a nanoporous structure, they have a potential application for a polymer electrolyte or a separator. Poly (VDF-co-HFP) is a polymer electrolyte binder. In order to improve their mechanical properties, poly (VDF-co-HFP)/PEGDMA NFMs were crosslinked by a gamma-ray irradiation. Then the crosslinked NFMs were characterized through an electrolyte uptake, IR structural analysis, and SEM morphological investigation.

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.4
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.

Comparison of Characteristics of Gamma-Ray Imager Based on Coded Aperture by Varying the Thickness of the BGO Scintillator

  • Seoryeong Park;Mark D. Hammig;Manhee Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.214-225
    • /
    • 2022
  • Background: The conventional cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)) scintillator-based gamma-ray imager has a bulky detector, which can lead to incorrect positioning of the gammaray source if the shielding against background radiation is not appropriately designed. In addition, portability is important in complex environments such as inside nuclear power plants, yet existing gamma-ray imager based on a tungsten mask tends to be weighty and therefore difficult to handle. Motivated by the need to develop a system that is not sensitive to background radiation and is portable, we changed the material of the scintillator and the coded aperture. Materials and Methods: The existing GAGG(Ce) was replaced with Bi4Ge3O12 (BGO), a scintillator with high gamma-ray detection efficiency but low energy resolution, and replaced the tungsten (W) used in the existing coded aperture with lead (Pb). Each BGO scintillator is pixelated with 144 elements (12 × 12), and each pixel has an area of 4 mm × 4 mm and the scintillator thickness ranges from 5 to 20 mm (5, 10, and 20 mm). A coded aperture consisting of Pb with a thickness of 20 mm was applied to the BGO scintillators of all thicknesses. Results and Discussion: Spectroscopic characterization, imaging performance, and image quality evaluation revealed the 10 mm-thick BGO scintillators enabled the portable gamma-ray imager to deliver optimal performance. Although its performance is slightly inferior to that of existing GAGG(Ce)-based gamma-ray imager, the results confirmed that the manufacturing cost and the system's overall weight can be reduced. Conclusion: Despite the spectral characteristics, imaging system performance, and image quality is slightly lower than that of GAGG(Ce), the results show that BGO scintillators are preferable for gamma-ray imaging systems in terms of cost and ease of deployment, and the proposed design is well worth applying to systems intended for use in areas that do not require high precision.