• Title/Summary/Keyword: Gamma test

Search Result 1,070, Processing Time 0.026 seconds

Development of a DDA+PGA-combined non-destructive active interrogation system in "Active-N"

  • Kazuyoshi Furutaka;Akira Ohzu;Yosuke Toh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4002-4018
    • /
    • 2023
  • An integrated neutron interrogation system has been developed for non-destructive assay of highly-radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20 mg and it is not affected by intense neutron background up to 1.57 × 107 s-1 and gamma ray of 4.43 × 1010 s-1. The gamma-ray background counting rate at the PGA detector was reduced down to 3.9 × 103 s-1 even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting 0.783 g of boron and about 86.8 g of gadolinium in 30 min.

A Study on the Optimization of Small Size TFT-LCD through Automatic Gamma Correction (Automatic Gamma 보정으로 인한 중소형 TFT-LCD의 최적화 연구)

  • Min, Byung-Chan;Yi, Jun-Shin;Kwag, Jin-Oh;Lee, Kon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2051-2052
    • /
    • 2006
  • 본 연구는 HHP,PDA,PMP,CNS 등등에 사용되는 중소형 A-Si:H TFT LCD 에서의 Automatic Gamma Correction 적용으로 화질 최적화 구현에 좀 더 쉽고 빠르게 접근하게 되었다. Analog Gamma String 대신 1chip Drive IC에 집적된 Gamma resister Ladder를 A-Si:H TFT-LCD Panel 특성에 보다 정확하게 적용시키기 위해 새로운 알고리즘을 개발 했으며 이를 적용시킨 회로를 Test Board로 실제 구현해서 최종결과를 도출하였다. Kick-Rack 전압을 고려한 Asymmetry-Gamma Correction 구현까지 Automatic으로 1chip Drive IC의 Register를 산출 할 수 있도록 알고리즘을 구성했다.

  • PDF

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

Studies on the Stochastic Generation of Long Term Runoff (1) (장기유출랑의 추계학적 모의 발생에 관한 연구 (I))

  • 이순혁;맹승진;박종국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.100-116
    • /
    • 1993
  • It is experienced fact that unreasonable design criterion and unsitable operation management for the agricultural structures including reservoirs based on short terms data of monthly flows have been brought about not only loss of lives, but also enormous property damage. For the solution of this point at issue, this study was conducted to simulate long series of synthetic monthly flows by multi-season first order Markov model with selection of best fitting frequency distribution and to make a comparison of statistical parameters between observed and synthetic flows of six watersheds in Yeong San and Seom Jin river systems. The results obtained through this study can be summarized as follows. 1.Both Gamma and two parameter lognormal distribution were found to be suitable ones for monthly flows in all watersheds by Kolmogorov-Smirnov test while those distributions were judged to be unfitness in Nam Pyeong of Yeong San and Song Jeong and Ab Rog watersheds of Seom Jin river systems in the $\chi$$^2$ goodness of fit test. 2.Most of the arithmetic mean values for synthetic monthly flows simulated by Gamma distribution are much closer to the results of the observed data than those of two parameter lognomal distribution in the applied watersheds. 3.Fluctuation for the coefficient of variation derived by Gamma distribution was shown in general as better agreement with the results of the observed data than that of two parameter lognormal distribution in the applied watersheds both in Yeong San and Seom Jin river systems. Especially, coefficients of variation calculated by Gamma distribution are seemed to be much closer to those of the observed data during July and August. 4.It can be concluded that synthetic monthly flows simulated by Gamma distribution are seemed to be much closer to the observed data than those by two parameter lognormal distribution in the applied watersheds. 5.It is to be desired that multi-season first order Markov model based on Gamma distribution which is confirmed as a good fitting one in this study would be compared with Harmonic synthetic model as a continuation follows.

  • PDF

A Study on the Gamma Scanning Test Used for Nondestructive Test Radiation Shielding Material (방사선 차폐체의 감마스케닝검사법에 대한 고찰)

  • Seo, Kyung-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.4
    • /
    • pp.561-567
    • /
    • 1996
  • As nuclear industry in Korea is being expended, the number of user for radioisotope and radiation generators has being remarkably increased. As a result, radiation shielding problem for radiation safety has rasied as a question of great interest nowaday. In this report, gamma scanning test (GST), one of the nondestructive test methods of radiation shielding material was introduced and the review of the test method and its application were described. In addition for accurate evaluation of the test result, necessary basic equipments for the test and for improvement of the equipment were suggested. If the effective test method described above were widely and properly applied by GST related companies, the technology would be used effectively, as one of the safe nondestructive test for radiation shielding material in future.

  • PDF

A Study on the Prediction of Maximum Dry Density and Optimum Moisture Content in Soil Compaction (흙의 다짐에 있어서 최대건조밀도(最大乾燥密度)와 최적함수비(最適含水比)의 추정(推定)에 대(對)하여)

  • Kang, Yea-Mook;Cho, Seung-Seup;Kim, Jae-Young
    • Korean Journal of Agricultural Science
    • /
    • v.3 no.2
    • /
    • pp.207-213
    • /
    • 1976
  • In order to obtain the prediction of the maximum dry density and the optimum moisture content of soil without soil moisture test, compaction test results from 157 different places either under construction or already completed were analyzed. The analyzed results were as follow The relationship between the maximum dry density and the optimum moisture content of the soil showing a correlation coefficient of 0.96 indicated that there was a high correlation between them. From the above relationship we obtained the equation, ${\gamma}_{dmax.}={\frac{1}{0.4193+0.00937W_{opt.}}$ Equation between the optimum moisture content and the maximum wet density of the soil was $W_{opt.}={\frac{0.4193{\gamma}_{tmax.}}{0.937_{\gamma}_{tmax.}-0.01}$, and the values of the optimum moisture content being predicted with the maximum wet density of the soil showed a little difference between those and tested values. The values of the maximum dry density being predicted with the moisture content estimated by the maximum wet density of the soil were within the range of ${\pm}5%$ of its tested values. The relationship between the dry density and the void ratio showed a high correlation between them (${\gamma}=0.9706$). From the above relationship, we obtained the equation, ${\gamma}_{dmax.}={\frac{1}{0.3938+0.3426e}}$.

  • PDF

Bayesian Testing for the Shape Parameter of Gamma Distribution : An Encompassing Approach

  • Moon, Gyoung-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.4
    • /
    • pp.861-870
    • /
    • 2005
  • The Bayesian model selection procedures for the shape parameter of gamma distribution are proposed in order to test that the failure rate of gamma distribution is constant, increasing or decreasing. The encompassing intrinsic Bayes factor by Beger and Pericchi (1996) based on Jeffreys prior for shape parameter is used to investigate the usefulness of the proposed Bayesian model selection procedures via both real data and pseudo data.

  • PDF

Co60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

  • Shin, Goo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2065-2069
    • /
    • 2014
  • The DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with $Co^{60}$ gamma-ray sources. The irradiation with $Co^{60}$ gamma-rays was carried out at doses from 0 krad to 100 krad to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 krad to 30 krad without any error.

A Comparative Experiments for Tube Agglutination Test of Pullorum Antiserum with gamma-Ray 60Co Irradiated Salmonella pullorum (방사성동위원소(放射性同位元素)로 처리(處理)한 추백리균(雛白痢菌)의 응집반응(凝集反應)에 대한 비교시험(比較試驗))

  • Seo, Boo Kap
    • Korean Journal of Veterinary Research
    • /
    • v.16 no.1
    • /
    • pp.7-10
    • /
    • 1976
  • An agglutinability between naturally infected positive chicken serum of pullorum disease and hyperimmumized rabbit antiserum was compared. And the following results were obtained and summarized. 1. On the agglutinability, Salmonella pullorum antigen which irradiated gamma-ray was more excellent than another both formalized and heated antigen. 2. Time of judgemented as positive titer in the tube agglutination test to the naturally infected positive chicken serum was it most suitable for 12 hours at $37^{\circ}C$. 3. Agglutination titer of positive immune chicken serum against gamma-ray irradiate Salmonella pullorum were as 320~640x.

  • PDF

Closeness of Lindley distribution to Weibull and gamma distributions

  • Raqab, Mohammad Z.;Al-Jarallah, Reem A.;Al-Mutairi, Dhaifallah K.
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.2
    • /
    • pp.129-142
    • /
    • 2017
  • In this paper we consider the problem of the model selection/discrimination among three different positively skewed lifetime distributions. Lindley, Weibull, and gamma distributions have been used to effectively analyze positively skewed lifetime data. This paper assesses how much closer the Lindley distribution gets to Weibull and gamma distributions. We consider three techniques that involve the likelihood ratio test, asymptotic likelihood ratio test, and minimum Kolmogorov distance as optimality criteria to diagnose the appropriate fitting model among the three distributions for a given data set. Monte Carlo simulation study is performed for computing the probability of correct selection based on the considered optimality criteria among these families of distributions for various choices of sample sizes and shape parameters. It is observed that overall, the Lindley distribution is closer to Weibull distribution in the sense of likelihood ratio and Kolmogorov criteria. A real data set is presented and analyzed for illustrative purposes.