• Title/Summary/Keyword: Gamma rays

Search Result 607, Processing Time 0.039 seconds

Analysis of Radiation Dose Enhancement for Spread Out Bragg-peak of Proton (확산된 피크의 양성자에서 선량 증강 현상에 대한 분석)

  • Hwang, Chulhwan;Kim, JungHoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.253-260
    • /
    • 2019
  • Radiation dose enhancement is a method of increasing the cross section of interaction, thus increasing the deposited dose. This can contribute to linear energy transfer, LET and relative biological effectiveness, RBE. Previous studies on dose enhancement have been mainly focused on X, ${\gamma}-rays$, but in this study, the dose enhancement was analyzed for proton using Monte Carlo simulation using MCNP6. Based on the mathematical modeling method, energy spectrum and relative intensity of spread out Bragg-peak were calculated, and evaluated dose enhancement factor and dose distribution of dose enhancement material, such as aurum and gadolinium. Dose enhancement factor of 1.085-1.120 folds in aurum, 1.047-1.091 folds in gadolinium was shown. In addition, it showed a decrease of 95% modulation range and practical range. This may lead to an uncertain dose in the tumor tissue as well as dose enhancement. Therefore, it is necessary to make appropriate corrections for spread out Bragg-peak and practical range from mass stopping power. It is expected that Monte Carlo simulation for dose enhancement will be used as basic data for in-vivo and in-vitro experiments.

Borehole Elemental Concentration Logs: Theory, Current Trends and Next Level (암석구성성분검층: 원리, 연구동향 및 향후 과제)

  • Shin, Jehyun;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.149-159
    • /
    • 2019
  • Borehole elemental concentration logging, measuring neutron-induced gamma rays by inelastic scattering and neutron capture interactions between neutron and formation, delivers concentrations of the most common elements found in the minerals and fluids of subsurface formation. X-ray diffraction and X-ray fluorescence analysis from core samples are traditionally used to understand formation composition and mineralogy, but it represents only part of formations. Additionally, it is difficult to obtain elemental analysis over the whole intervals because of poor core recovery zones such as fractures or sand layers mainly responsible for groundwater flow. The development of borehole technique for in situ elemental analysis plays a key role in assessing subsurface environment. Although this technology has advanced consistently starting from conventional and unconventional resources evaluation, it has been considered as exclusive techniques of some major service company. As regards domestic research and development, it has still remained an unexplored field because of some barriers such as the deficiency of detailed information on tools and calibration facility for chemistry and mineralogy database. This article reviews the basic theory of spectroscopy measurements, system configuration, calibration facility, and current status. In addition, this article introduces the domestic researches and self-development status on borehole elemental concentration tools.

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

Alterations in the Properties of Agar by ionizing Radiation

  • Lee, Su-Rae;Park, Sang-Ki;Cho, Han-Ok
    • Nuclear Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.145-150
    • /
    • 1976
  • Alkali-treated red algae, Gracilaria sp. was irradiated with various doses of cobalt-60 gamma-rays and the yeild and properties of agar extracted from the seaweed were examined and compared with the quality of commercial agar powder after irradiation. Extraction yield of agar from irradiated seaweed was proportionally increased as the radiation dose was raised up to 2 Mrad whereas it tended to decrease slightly thereafter. Gelation ability, gelation point, gel hardness and specific viscosity of the agar were increased up to 1 Mrad and decreased at higher dose levels while its melting point, total nitrogen, crude ash and total sulfur decreased up to 1 Mrad level and remained unchanged thereafter. Irradiation of commercial agar powder caused remarkable decreases in the gelation ability, specific viscosity and gel hardness and slight decreases in the gelation point and melting point. The pattern of alterations in the properties of agar samples differed whether the polysaccharide was irradiated in free state or bound state in seaweed.

  • PDF

ANALYSIS OF CHARGE COLLECTION EFFICIENCY FOR A PLANAR CdZnTe DETECTOR

  • Kim, Kyung-O;Kim, Jong-Kyung;Ha, Jang-Ho;Kim, Soon-Young
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.723-728
    • /
    • 2009
  • The response property of the CZT detector ($5{\times}5{\times}5\;mm^3$), widely used in photon spectroscopy, was evaluated by considering the charge collection efficiency, which depends on the interaction position of incident radiation, A quantitative analysis of the energy spectra obtained from the CZT detector was also performed to investigate the tail effect at the low energy side of the full energy peak. The collection efficiency of electrons and holes to the two electrodes (i.e., cathode and anode) was calculated from the Hecht equation, and radiation transport analysis was performed by two Monte Carlo codes, Geant4 and MCNPX. The radiation source was assumed to be 59.5 keV gamma rays emitted from a $^{241}Am$ source into the cathode surface of this detector, and the detector was assumed to be biased to 500 V between the two electrodes. Through the comparison of the results between the Geant4 calculation considering the charge collection efficiency and the ideal case from MCNPX, an pronounced difference of 4 keV was found in the full energy peak position. The tail effect at the low energy side of the full energy peak was confirmed to be caused by the collection efficiency of electrons and holes. In more detail, it was shown that the tail height caused by the charge collection efficiency went up to 1000 times the pulse height in the same energy bin at the calculation without considering the charge collection efficiency. It is, therefore, apparent that research considering the charge collection efficiency is necessary in order to properly analyze the characteristics of CZT detectors.

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Biological indicator on radiation exposure using apoptosis in adult and newborn mice (성숙 및 신생마우스에서 아포프토시스를 이용한 방사선 피폭의 생물학적 지표)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jeong, Kyu-shik;Hyun, Byung-hwa;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.679-685
    • /
    • 1998
  • We have studied, by a nonisotopic in situ DNA end-labeling (ISEL) technique, frequency of apoptosis in the external granular layer (EGL) of the cerebellum after whole-body irradiation of newborn mice and intestinal crypt cell of adult mice by gamma-rays from $^{60}Co$. The extent of changes following 2 Gy(10.9 Gy/min) was studied at 2, 4, 6, 8, 12, or 24h after exposure. The maximal frequency was found 4-8h after exposure. The mice that received 0.18, 0.36, 0.54, 1.08, 1.98, or 3.96 Gy were examined 6h after irradiation. Measurements performed after irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model; frequency(%) of apoptotic cell in the newborn mice cerebellum was ($13.49{\pm}1.175$)D+$(-1.52{\pm}0.334)D^2$+0.048($r^2=0.981$, D = dose in Gy) and frequency(number per crypt) of apoptotic cell in the intestinal crypt of adult mice was ($3.857{\pm}0.420$)D+$(-0.535{\pm}0.120)D^2$+0.155($r^2=0.952$, D = dose in Gy). It provides the basis required for a better understanding of results which will be obtained in any further studies for biological responses of radiation using newborn and adult mice.

  • PDF

Response of LiF Thermoluminescent Dosimeter to Gamma-Rays as a Cavity Detector (LiF 열형광선량계(熱螢光線量計)의 감마선(線)에 대한 공동검출기(空洞檢出器)로서의 감응(感應))

  • Ha, C.W.;Yook, C.C.;Jun, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.10-14
    • /
    • 1976
  • Influence of the cavity size on the response of LiF TLD was theoretically investigated for a presumed system of spherical TLD cavity imbedded in a medium of polyethylene. Calculation of the response for different radii of the spherical cavity was carried out as a function of incident photon energy, applying recent cavity theory. The range of the radii covers 1.578 to 6.528 mm, while that of the incident photon energies extends from 0.02 to 3.0 MeV. As a results, the response of the LiF TLD imbedded in a medium as a cavity was found to be functions of its own size as wall as the incident photon energy.

  • PDF

Determination of the Phantom Scatter Factor ($S_P\;Factor$) using a small Block in the Phantom (작은 블럭을 이용한 판톰 내에서의 판톰 산란 인자(Sp Factor)측정법)

  • Yi Byong Yong;Hong Seok Min;Kim Jae Sung;Choi Eun Kyung;Chang Hyesook;Lee Myung Za;Chun Ha Chung
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.121-123
    • /
    • 1992
  • New measurement method for $S_{p}$ factors (Phantom Scatter Factors) is presented. The theoretical development of the approach is disscused showing that $S_{p}$ factors can be obtained from three measurements of ionnization in a blocked, reference field and open field. This method has been tested using $^{60}Co$ gamma rays. The results were within 1% deviation between the theory and the experiment for the $S_{p}$ factor. The new method does not need air measurement, and we could could determine the $S_P$ factors with a small piece of block

  • PDF

Radioprotective effects of dimethyl sulfoxide in the artificial skin reconstructed with cultured human cells (배양된 사람 세포를 이용해 제작한 인공피부에서 방사선조사에 대한 dimethyl sulfoxide의 보호 효과)

  • Ryu Young-Ha;Choi Karp-Shik;Song In-Hwan
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • Purpose: To evaluate cultured human artificial skin as an experimental model for studying radiation effects in vitro. Materials and Methods: The skin was constructed by culturing keratinocytes over collagen lattice which made by culturing fibroblasts. Two groups were irradiated to gamma rays at single dose of 25 Gy with or without 3.5% of DMSO. Ultrastructures were investigated by electron microscopy after irradiation. The number of epidermal layers and expression of cytokeratin (CK) 14 & 10 were also seem by light microscopy. Results: At 2 days after irradiation in experimental group without DMSO, necrotic cells were rarely found in the spinosal layer and undercornified cells were visible in the homey layer. Similar findings were also found in experimental group with DMSO but in mild form. The number of epidermal layers in experimental group without DMSO were significantly fewer than other group. CK 14 expressed in all the layer excluding homey layer but CK 10 expressed over 3∼4 basal layers. Such patterns of CK expression were similar to all groups. It is suggested that structures of the keratinocytes and epidermal formation could be disturbed by irradiation in artificial skin and that DMSO can protect these damages. Conclusion : Therefore this work could be used as an organotypic experimental model in vitro using human cells for studying radiation effect in skin. Furthermore structural findings provided in this study could be used as useful basic data in further study using this model.

  • PDF