• Title/Summary/Keyword: Gamma radiography

Search Result 35, Processing Time 0.023 seconds

Evaluation of Bone Uptake on Tc-99m-MDP in Immediate and Delayed Dental Implants (즉시형과 지연형 치아 임플란트에서 Tc-99m-MDP의 Bone Uptake 평가)

  • 김중현;김명환;이원국;이재영;강성수;최석화
    • Journal of Veterinary Clinics
    • /
    • v.20 no.2
    • /
    • pp.207-211
    • /
    • 2003
  • This investigation aimed to determine the relative merit of osseointegration in immediate and delayed implantation in the dog mandible using radiography and bone scintigraphy. five adult mongrel dogs with a mean weight of 8.5 kg were used in this investigation. During the entire study period. all dogs were fed with a soft commercial diet and water ad libitum to minimize functional loading of the implant. Twenty titanium alloy systems 4 mm in diameter and 10 mm in length blasted with calcium phosphate were prepared for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, radiography and bone scintigraphy were conducted. Bone scans were obtained using a large field of view gamma camera equipped with a collimator about 3 hours after intravenous injection of Tc-99m-MDP to the dogs. All the dogs were evaluated weekly for inflammation, necrosis, and other of the bone or sort tissue. Significant macroscopic lesions were not detected. Radioisotope scintigraphy with Tc-99m-MDP hat proved to be a reliable method for measuring increased bone activity at specific skeleton tissue sites. In conclusion, osseointegration in peri-implant bone did not differ significantly between the immediate and delayed implant procedures during the experimental period. The immediate implant may be an alternative treatment of implant insertion in animals.

Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning (Ir-192 밀봉선원의 표면오염 방지)

  • Kuk, Il Hiun;Park, Chun Deuk;Koo, Ja Ho
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

Interpretation of Making Techniques and Material Characteristics for Molding Clay of Four Guardian Statues in Wanju Songkwangsa Temple, Korea (완주 송광사 소조사천왕상의 재질특성 및 제작기법 해석)

  • Han, Doo Roo;Lee, Chan Hee;Jo, Young Hoon
    • Journal of Conservation Science
    • /
    • v.28 no.4
    • /
    • pp.353-366
    • /
    • 2012
  • This study was interpreted the making techniques of the Four Guardian Statues in Wanju Songkwangsa Temple, and retained basic data necessary for conservation treatment and restoration of the same material by estimating the soil source. The molding clay used in the Statues showed a variety of material characteristics according to different layers. The first and mid layers estimated as the original molding clay are composed of the same kind of soil. The soil of the finish layer was also confirmed to be genetically similar to that of the first and mid layers, despite little discrepancy. The former restoration layer was inconsistent in material characteristics with the original molding clay in every result of analysis. As a result of gamma radiography, making techniques of the Statues were able to identify the figure of the frame connecting the woods of main pillar frame to sub-frame and steel wire with ㄷ-clamp, nails and straw ropes, and the molding clay constructed upon the frame. Meanwhile, provenance interpretation confirmed that the soil of the estimated provenance area is of the same origin as the soil of the finish layer, and therefore is an appropriate material for conservation treatment. This result will contribute to the research on making techniques of the molding clay Statues.

The Protective Effect of Chondroitin from Raja kenojei Cartilage on Collagen-induced Arthritis in DBA/1J Mice

  • Jin, Cheng-Hao;Yang, Ung;Kim, Song-Hee;Ryu, Jae-Won;Lee, Jae-Chang;Lee, Dong-Seok;Lee, Tae-Hoon
    • Food Science and Biotechnology
    • /
    • v.16 no.4
    • /
    • pp.594-599
    • /
    • 2007
  • In this study, we evaluated whether the oral administration of chondroitin from the cartilage of Raja kenojei is effective on the progression of rheumatoid arthritis (RA), using collagen-induced arthritic (CIA) mice. Arthritis development was delayed dose-dependently in the chondroitin-treated groups. The pre- and late-treated groups receiving 1,000 mg/kg of chondroitin had clinical scores that were reduced significantly by 56.9 (p<0.05) and 43.3% (p<0.05), respectively, compared to the vehicle-treated groups. Hematoxylin eosin staining and X-ray radiography showed that the chondroitins reduced the infiltration of inflammatory cells and prevented joint destruction of the knee and paw. Reverse transcription-polyerase chain reaction analysis revealed that chondroitin administration inhibited the expressions of tumor necrosis $factor-{\alpha}$ ($TNF-{\alpha}$), $interlukin-1{\beta}$ ($IL-1{\beta}$), and $interferon-{\gamma}$ ($IFN-{\gamma}$) in joints more than the administration of vehicle. Chondroitin treatment also decreased the production of rheumatoid factors (RF), IgG and IgM, in the serum of CIA mice. These results indicate that chrondroitin administration has a protective effect involving the inhibition of pro-inflammatory cytokine production in CIA mice.

Evaluation of dose delivery accuracy due to variation in pitch and roll (세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가)

  • Jeong, Chang Young;Bae, Sun Myung;Lee, Dong Hyung;Min, Soon Ki;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.239-245
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.

Prevalence of Latent Tuberculosis Infection among Medical Students in South Korea

  • Jung, Da Ho;Jo, Kyung-Wook;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.4
    • /
    • pp.219-223
    • /
    • 2012
  • Background: We investigated the prevalence of latent tuberculosis infection (LTBI) among medical students in South Korea. Methods: Students from one medical school, who were in second- or third-year classes before clerkship course, were enrolled for three consecutive years in the study. A standard questionnaire was given to each participant, and tuberculin skin test (TST), QuantiFERON-TB GOLD In-Tube (QFT-GIT) assay, and chest radiography were performed. Results: A total of 153 participants were enrolled in the study. The mean age of the subjects was $21.9{\pm}0.9$ years, 105 (68.6%) were male, and 132 (86.3%) had been vaccinated with Bacille Calmette-Gu$\acute{e}$rin (BCG). Four students (2.6%) had a history of contact with tuberculosis (TB) patients during medical practice. No abnormal chest radiograph findings were found for any of the subjects. Of the 153 subjects, 23 (15.0%) tested positive for the TST, and 8 (5.2%) tested positive for the QFT-GIT. The agreement between the two tests was determined to be 0.34 using kappa coefficients. Of the four students who had a history of contact with TB patients, only one subject tested positive for both tests, and the other three students tested negative for both tests. Conclusion: A low prevalence of LTBI was found among medical students before clerkship course in South Korea.

Renal Tubular Carcinoma in a Cocker Spaniel Dog (코커 스파니엘에서 신장세포암종)

  • Kye, Eun-Young;Yun, Sung-Ho;Jang, Hwan-Soo;Kwak, Dong-Mi;Ku, Sae-Kwang;Jang, Kwang-Ho;Kwon, Young-Sam
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.431-434
    • /
    • 2011
  • A 7-year-old neutered male Cocker spaniel was referred to Veterinary Medical Teaching Hospital, Kyungpook National University with a left abdominal mass, anorexia and weight loss. Hematologic test and biochemical panel showed severe leukocytosis, mild anemia, mild hypoalbuminemia and a marked elevation in gamma glutamyl transferase (GGT). Radiography demonstrated a large mass on the left kidney and there was no evidence of pulmonary metastases. Histopathologic features of the mass were consistent with renal tubular carcinoma. The dog was treated with unilateral nephrectomy. During the follow-up, the dog died 6 months after surgery.

Surgical Correction of Single Extrahepatic Portosystemic Shunt Using Ameroid Constrictor in a Dog (Ameroid Constrictor를 이용한 개에서의 단순 간외성 간문맥전신단락증의 치료)

  • 정성목;이충호;양정환;김완희;최민철;윤정희;이주명;권오경;남치주
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.442-447
    • /
    • 2001
  • A 2-year-old 4.0-kg female Shih Tzu with history of hematemesis and melena was referred to Veterinary Medical Teaching Hospital, Seoul national University for further evaluation and treatment. During physical examination, the dog revealed mild depression, dry mucous membrane and abdominal pain. Hematologic values were normal and serum chemical values showed increased serum bile acid (53.47 umol/l, preprandial), fasting serum ammonia concentration (184 g/dl), alanine transferase (98 U/L), alkaline phosphatase (871 U/L) and gamma glutamyl transpeptidase (21 U/L), and decreased blood urea nitrogen (4 mg/dl), total protein (4.1 g/dl) and albumin (1.2 g/dl). Microhepatica was shown in abdominal radiography. During the ultrasound examination, dilated tortuous vein communicating with caudal vena cava ws observed near the stomach. Intraoperative jejunal vein portography was performed during laparotomy to confirm the location and size of shunt vessel. According to history taking, physical examination, hematologic and serum chemical examination and radiographic study, it was diagnosed as single extrahepatic portosystemic shunt. The anomalous vessel (7 mm, o.d.) that enter the caudal vena cava from the left gastric vein, near the level of the diaphragm, was identified. A Ameroid constrictor (5 mm, i.d.) was applied to the shunting vessel near the caudal vena cava. Hematologic and serum chemical values recovered gradually and were revealed normal values 4 months after surgery. Four month after surgery serum bile acids concentrations were 0.56 $\mu$mol/l (preprandial) and 18.45 umol/l (postprandial). Abdominal radiograph showed normal gastric axis and it revealed normal size of the liver. Fine texture and increased echogenecity of liver and enlargement of portal vein were shown in ultrasonography. Single extrahepatic portosystemic shunt might be treated surgically using Ameroid constrictor.

  • PDF

Study on the effect of long-term high temperature irradiation on TRISO fuel

  • Shaimerdenov, Asset;Gizatulin, Shamil;Dyussambayev, Daulet;Askerbekov, Saulet;Ueta, Shohei;Aihara, Jun;Shibata, Taiju;Sakaba, Nariaki
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2792-2800
    • /
    • 2022
  • In the core of the WWR-K reactor, a long-term irradiation of tristructural isotopic (TRISO)-coated fuel particles (CFPs) with a UO2 kernel was carried out under high-temperature gas-cooled reactor (HTGR)-like operating conditions. The temperature of this TRISO fuel during irradiation varied in the range of 950-1100 ℃. A fission per initial metal atom (FIMA) of uranium burnup of 9.9% was reached. The release of gaseous fission products was measured in-pile. The release-to-birth ratio (R/B) for the fission product isotopes was calculated. Aspects of fuel safety while achieving deep fuel burnup are important and relevant, including maintaining the integrity of the fuel coatings. The main mechanisms of fuel failure are kernel migration, silicon carbide corrosion by palladium, and gas pressure increase inside the CFP. The formation of gaseous fission products and carbon monoxide leads to an increase in the internal pressure in the CFP, which is a dominant failure mechanism of the coatings under this level of burnup. Irradiated fuel compacts were subjected to electric dissociation to isolate the CFPs from the fuel compacts. In addition, nondestructive methods, such as X-ray radiography and gamma spectrometry, were used. The predicted R/B ratio was evaluated using the fission gas release model developed in the high-temperature test reactor (HTTR) project. In the model, both the through-coatings of failed CFPs and as-fabricated uranium contamination were assumed to be sources of the fission gas. The obtained R/B ratio for gaseous fission products allows the finalization and validation of the model for the release of fission products from the CFPs and fuel compacts. The success of the integrity of TRISO fuel irradiated at approximately 9.9% FIMA was demonstrated. A low fuel failure fraction and R/B ratios indicated good performance and reliability of the studied TRISO fuel.

Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays (Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가)

  • Han, Su Chul;Choi, Sang Hyoun;Park, Seungwoo;Kim, Chul Hang;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Chan Hyeong;Ji, Young Hoon;Yi, Chul Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • We aimed to evaluate the dosimetric characteristics of reproducibility, linearity and dose dependence of optical stimulated luminance dosimeter (OSLD) in the Co-60 Gamma-rays and to analyze with a precedent study in field of the diagnostic radiography and radiotherapy. The reproducibility was 0.76% of the coefficient of variation, the homogeneity was within 1.5% of the coefficient of variation and OSLD had supra-linear response more than 3 Gy. So the correlation between dose and count was fitted by quadratic function. The count depletion by repeated reading was 0.04% per reading regardless of the irradiated dose. And the half time of decay curve according to the irradiated dose was 0.68 min. with 1 Gy, 1.04 min. with 5 Gy, and 1.10 min. with 10 Gy, respectively. In case of annealing for 30 min, the removal rate was 88% with 1 Gy, 90% with 5 Gy, and 92% with 10 Gy, respectively and 99% in case of annealing time for 4 hour. It is feasible to use OSLDs for dose evaluation in Co-60 Gamma-rays when considering the uncertainty on the procedure according to the irradiated dose.