• Title/Summary/Keyword: Gamma radiation detection

Search Result 192, Processing Time 0.029 seconds

Radiation Detection System for Prevention of Illicit Trafficking of Nuclear and Radioactive Materials

  • Kwak, Sung-Woo;Chang, Sung-Soon;Yoo, Ho-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.167-171
    • /
    • 2010
  • Fixed radiation portal monitors (RPMs) deployed at border, seaport, airport and key traffic checkpoints have played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM is usually large and heavy and can't easily be moved to different locations. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for search and detection of nuclear and radioactive materials during road transport. Field tests to characterize the developed detection system were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of measurements and detection limits of our system are described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle.

Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources (다종 감마선 공간분포 측정을 위한 고감도 검출센서 및 탐지모듈 개발)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.705-707
    • /
    • 2017
  • Stereo-based spatial radiation detection devices can obtain not only spatial distribution information about the radiation source but also distance information from the detection device to the source. And it provides more efficient information on the source than the existing radiation imaging device. In order to provide high-speed information on the spectrum and type of gamma-ray source, a high-sensitivity detection sensor with high sensitivity is required, and a technique capable of solving the saturation phenomenon at a high dose is needed. In this paper, we constructed a high sensitivity sensor for the measurement of multiple gamma - ray spatial distributions using improved function of detection module to solve saturation to high dose and conducted research to increase the scope of a single detector. The result of this paper improves the performance of gamma ray.

  • PDF

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

Study of a Protection Technology to the Transient Radiation for the Semiconductors (반도체에 대한 과도방사선 방호기술연구)

  • Lee, Nam-ho;oh, Sung-Chan;Jeong, Sang-hun;Hwang, Young-gwan;Kim, Jong-yul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1023-1026
    • /
    • 2013
  • The electronic equipment which was exposed to high level pulsed radiation is damaged as Upset, Latchup, and Burnout. Those damages has come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appeared as losses of power in military weapon system or of blackout in aerospace equipment and eventually caused in gross loss of national. In this paper, we have implemented a RDC(Radiation detection and control module) as part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator is designed to protect the important electronic circuits from the pulse radiation. To verify the functionality of the RDC, LM118s which had damaged by the pulse radiation were tested. The test results showed that the test sample applied with a RDC was worked well in spite of the irradiation of the same pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with RDC had the functionality of radiation protection to the electronic devices.

  • PDF

Study of Radiation Mapping System for Water Contamination in Water System (방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구)

  • Na, Teresa W.;Kim, Han Soo;Yeon, Jei Won;Lee, Rena;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

The study of the optimized collimator structure for gamma-ray detector (감마선 탐지장치를 위한 Collimator 구조 최적화 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.835-836
    • /
    • 2014
  • In this paper, we have designed the collimator of different sizes structure for the development of stereo radiation detector. And we conducted a study of the optimal structure of collimator using the results of the Gamma-ray irradiation test associated with the change of the incident angle. According to the results of the performance analysis, and showed the results of the optimal incident angle 2. Results of the paper are used as basic data for designing the structure of the detector efficiency for radiation detection.

  • PDF

Effects of Irradiation Temperature on the Sensory Quality Improvement of Gamma-irradiated Ganjang-gejang, Korean Traditional Marinated Raw Crab Portunus trituberculatus in Soybean Sauce

  • Park, Jae-Nam;Byun, Eui-Baek;Han, In-Jun;Song, Beom-Seok;Sohn, Hee-Sook;Park, Sang-Hyun;Byun, Eui-Hong;Yoon, Minchul;Sung, Nak-Yun
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 2015
  • This study was conducted to confirm quality properties of sterilized Ganjang-gejang (marinated crab Portunus trituberculatus) with Korean soy sauce using by gamma irradiation and to improve quality of sterilized Ganjang-gejang. The Ganjang-gejang was irradiated at dose of 3, 6, 9, 12, and 15 kGy by gamma irradiation and there was evaluated in microbiological, physicochemical, and sensory properties. Total aerobic bacteria and fungi contents of non-irradiated samples were about 6 and 4 log CFU/g level, respectively. Gamma-irradiated samples at above 9 kGy did not contain aerobic bacteria or fungi at detection limit less than 2 log CFU/g, but sensory scores were significantly decreased depending on the irradiation dose. To improve the sensory qualities of gamma-irradiated Ganjang-gejang, the temperature was adjusted during sample irradiation. When samples were irradiated under freezing temperatures, especially on dry ice, the TBARS and the deterioration of sensory qualities of Ganjan-Gejang were reduced. Different odor patterns were observed among samples, as observed using electronic nose analysis system. The results of this study indicated that treatment with irradiation under low temperatures may help to preparing high-quality Ganjang-gejang.

Sterilization of Freeze Dried Manila Clam (Ruditapes philippinarum) Porridge for Immuno-Compromised Patients

  • Song, Beom-Seok;Park, Jae-Nam
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.205-210
    • /
    • 2016
  • This study was conducted to evaluate the combined effect of gamma irradiation and different conditions (vacuum packaging, antioxidant and freezing) on the microbiological and sensory characteristics of freeze dried Manila clam porridge (MCP) for immuno-compromised patient food. MCP can be sterilized at 1 kGy to 10 kGy. The initial counts of total aerobic bacteria and yeast molds in the non-irradiated MCP were $2.4{\pm}0.5$ and $1.2{\pm}0.3{\log}\;CFU\;g^{-1}$, respectively, but gamma irradiation significantly decreased the total aerobic bacteria to below the detection limit ($1{\log}\;CFU\;g^{-1}$) (5 kGy). Moreover, gamma irradiation effectively eliminated yeasts/molds at dose below than 1 kGy. However, gamma irradiation accelerated the increase of lipid oxidation and therefore, decreased the sensory characteristics of MCP as irradiation dose increased. To improve the sensory qualities of gamma irradiated MCP, combination treatment (vacuum packaging, 0.1% vitamin C) were applied. There was no significant difference in the overall acceptance scores between the combined-treatment sample (5.6 points) and the non-irradiated samples (6.0). The results indicate that combination treatment (vacuum packaging, 0.1% vitamin C) may help to maintain the quality of MCP. Therefore, it considered that irradiation of MCP with combined treatment and this is an effective method for the consumption as a special purpose food such as for space travel or immuno-compromised patients.

Effect of Gamma Irradiation on Microbial Populations in the Dried Raw Materials and Saengsik Powder (감마선 조사에 따른 원료분말 및 생식의 미생물 제어 효과)

  • Choi, Soo-Jeong;Park, Jae-Nam;Song, Beom-Seok;Yoon, Young-Min;Han, In-Jun;Park, Jong-Heum;Kim, Jae-Kyung;Byun, Eui-Baek;Lee, Ju-Woon;Hong, Seong-Gil;Yook, Hong-Sun;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.177-182
    • /
    • 2013
  • This study was conducted to evaluate the effect of gamma irradiation on the microbial populations of dried raw materials (9 products) and Saengsik powder. The samples were gammairradiated at doses of 2, 4, 6 and 8 kGy and the microbiological populations were evaluated. The total numbers of bacteria and Bacillus cereus in non-irradiated dried-raw materials for Saengsik powder was 1.3~3.4 and $1.7{\sim}2.4log\;CFU\;g^{-1}$. However, gamma irradiation reduced the microbiological populations in all samples, and Saengsik powder were sterilized at more than 6 kGy. Moreover, Clostridium perfringens were not observed in all samples within detection limit (<$1log\;CFU\;g^{-1}$). Therefore, the results of this study suggest that gamma irradiation at 6 kGy is sufficient to sterilize Saengsik powder, and thus, irradiated Saengsik powder at 6 kGy fulfills the microbiological requirements for sterilized food.

Microbiological and Sensory Characteristics of Gamma-irradiated Frozen Bibimbap (감마선 조사 냉동비빔밥의 미생물 및 관능적 품질특성)

  • Park, Jae-Nam;Song, Beom-Seok;Yoon, Young-Min;Choi, Soo-Jeong;Park, Jong-Heum;Kim, Jae-Kyung;Byun, Eui-Baek;Lee, Ju-Woon;Han, In-Jun;Sohn, Hee-Sook;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.93-99
    • /
    • 2013
  • This study was conducted to evaluate the effect of gamma irradiation on the microbiological and sensory characteristics of frozen Bibimbap. Frozen Bibimbap vegetables were contaminated by microbial levels of $2.70{\sim}6.67log\;CFU\;g^{-1}$ in total aerobic bacteria. Frozen Bibimbap was contaminated by microbial levels of $4.8log\;CFU\;g^{-1}$ in total aerobic bacteria, but microorganisms in gamma-irradiated samples at above 25 kGy were not found at detection limit less then $1log\;CFUg^{-1}$. Sensory characteristics of the gamma-irradiated Bibimbap were decreased depending upon the irradiation dose, and sensory scores of the samples irradiated with doses higher than 10 kGy were significantly decreased. Therefore, the application of combination of the various food processing technology should be considered for the sterilization of Bibimbap, without any deterioration of quality occurred by high dose irradiation.