• Title/Summary/Keyword: Gamma Radiation

Search Result 2,156, Processing Time 0.03 seconds

The Change of the Salivary Function after the High Dobe Radioiodine Treatment in the Patients with Differentiated Thyroid Cancer (갑상선암 환자의 방사성옥소 치료 후 타액선 기능의 변동)

  • Lim, S.M.;Hong, S.W.;Lee, J.O.;Kang, T.W.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.7-12
    • /
    • 1989
  • The pain, swelling of salivary glands and dry mouth are not infrequent complication of the high dose radioiodine treatment in the patients with differentiated thyroid cancer. The purpose of this study was, by the dynamic salivary scintigraphy, to observe the change of the salivary function after the high dose $(150\sim200mci)$ radioiodine treatment. From May 1987 to April 1988, the dynamic salivary scintigraphy with 5mci of $^{99m}Tc-pertechnetate$ and gamma camera was performed before and 7 days after the radiolodine treatment in 7 patients with differentiated thyroid cancer. Just after the dynamic scintigraphy, the stimulation test with vitamin C solution of pH3.0 and poststirnulation scintigraphy were done, and the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were calculated for each gland. There was positive correlation between the radioactivity uptake index and excretion fraction after the stimulation. The salivary clearance after the stimulation was $18.96{\pm}8.95ml/min$ in the pretreatment state, and $14.37{\pm}7.7ml/min$ after the radioioine treatment. After the radioiodine treatment, the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were significantly reduced in the parotid glands, but only the excretion fraction was reduced in the submandibular glands. The more the pretreatment salivary clearance after the stimulation was, the % change after the treatment was smaller. Further studies on the relation between the radiation dose in the salivary glands and the change of their function, and the long-term observation for the recovery of function are expected.

  • PDF

The Potential Usefulness of Magnetic Resonance Guided Focused Ultrasound for Obsessive Compulsive Disorders

  • Jung, Hyun Ho;Chang, Won Seok;Kim, Se Joo;Kim, Chan-Hyung;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.427-433
    • /
    • 2018
  • Obsessive compulsive disorder is a debilitating condition characterized by recurrent obsessive thoughts and compulsive reactions. A great portion of the obsessive compulsive disorder (OCD) patients are managed successfully with psychiatric treatment such as selective serotonin-reuptake inhibitor and cognitive behavioral psychotherapy, but more than 10% of patients are remained as non-responder who needs neurosurgical treatments. These patients are potential candidates for the neurosurgical management. There had been various kind of operation, lesioning such as leucotomy or cingulotomy or capsulotomy or limbic leucotomy, and with advent of stereotaxic approach and technical advances, deep brain stimulation was more chosen by neurosurgeon due to its characteristic of reversibility and adjustability. Gamma knife radiosurgery are also applied to make lesion targeting based on magnetic resonance (MR) imaging, but the complication of adverse radiation effect is not predictable. In the neurosurgical field, MR guided focused ultrasound has advantage of less invasiveness, real-time monitored procedure which is now growing to attempt to apply for various brain disorder. In this review, the neurosurgical treatment modalities for the treatment of OCD will be briefly reviewed and the current state of MR guided focused ultrasound for OCD will be suggested.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

Effect of Citrus Pectin Oligosaccharide Prepared by Irradiation on High Cholesterol Diet B6.KOR-ApoE Mice

  • Kang, Ho-Jin;Kwon, Joong-Ho;Ahn, Dong-Uk;Lee, Ju-Woon;Lee, Wan-Kyu;Jo, Cheo-Run
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.884-888
    • /
    • 2009
  • Effect of citrus pectin oligosaccharides produced by irradiation was studied on the ability to improve lipid metabolism and hypercholesterolemia in mice fed high cholesterol diets. A total of 35 mice were divided into 5 groups and fed the following diets for 6 weeks: normal diet (C), 0.5% cholesterol (CH), 0.5% cholesterol+5% non-irradiated pectin (P), 0.5% cholesterol+5% irradiated pectin at 20 kGy (PIR), and 0.5% cholesterol+5% irradiated at 20 kGy and dialyzed (PIR-F). CH group had significantly higher serum triglycerides, total cholesterol, and low density lipoprotein (LDL)-cholesterol contents than pectin oligosaccharide-treated groups (p<0.05). Triglycerides and total cholesterol contents was the lowest in C and PIR-F and followed by PIR and P group, and CH group had significantly higher LDL-cholesterol. Serum high density lipoprotein (HDL)-cholesterol content in C group was not different from that in CH and P groups, but lower than that of PIR and PIR-F groups. These results suggest that pectin oligosaccharides produced by irradiation can reduce the levels of serum triglyceride, total cholesterol, and LDL-cholesterol in the blood of mice fed high-cholesterol diets and therefore, irradiation can be used as a tool to produce functional oligosaccharides from citrus pectin.

Study of the used deuterium absorption material disposal

  • Kim, Dong-Gyung;Kim, Myung-Chul;Lee, Bum-Sig;Lee, Sang-Gu
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.64-72
    • /
    • 2004
  • The dryer (ten per unit) are operating to remove tritium in PHWR(Pressurized Heavy Water Reactor). There are coming out heavy water adsorbent from operating the dryer (95 drums for ten year per unit) The amount of radioactivity of heavy water adsorbent almost exceed ninety times more than disposal limit-in-itself showed by The Ministry of Science and Technology. It has to be disposed whole radioactive waste products, however there are problems of increase at the expense of their permanent disposal. In this research, We have studied how to remove kinds of nuclear materials and amount of tritium with in heavy water adsorbent. As the result we could develop disposal equipment and apply it. D20 adsorbent have to contain below Gamma nuclide O.3Bq/g and tritium 100Bq/g "The Regulation for disposal of the radioactivity wastes" showed by The Ministry of Science and Technology. There fore. So as to remove amount of tritium and kinds of nuclear materials (DTO) we needed a equipment. Also we have studied how to remove effectively radioactivity with in Adsorbent. As cleaning heavy water adsorbent and drying on each condition (temperature for drying and hours for cleaning). Because there is something to return heavy water adsorbent by removing impurities within adsorbent when it is dried o high temperature. After operating, we have been applying this research to the way to dispose heavy water adsorbent. Through this we could reduce solid waste products and the expense of permanent disposal of radioactive waste products and also we could contribute nuclear power plant run safely. According to the result we could keep the best condition of radiation safety super vision and we could help people believe in safety with Radioactivity wastes control for harmony with Environment.

  • PDF

TID and SEGR Testing on MOSFET of DC/DC Power Buck Converter (DC/DC 강압컨버터용 MOSFET의 TID 및 SEGR 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.981-987
    • /
    • 2014
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a MOSFET (metal-oxide semiconductor field effect transistor), a PWM-IC (pulse width modulation-integrated circuit) controller, inductor, capacitor, etc. It is shown that the variation of threshold voltage and the breakdown voltage in the electrical characteristics of MOSFET occurs by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 5 heavy ions make the gate of MOSFET broken in SEGR (Single Event Gate Rupture) testing. TID testing on MOSFET is accomplished up to the total dose of 40 krad, and the cross section($cm^2$) versus LET(MeV/mg/$cm^2$) in the MOSFET operation is studied at SEGR testing after implementation of the controller board.

Quality Evaluation and Physical Identification of Irradiated Dried Fruits (감마선 조사 건조과일의 품질평가 및 물리적 판별)

  • Jung, Jae-Hoon;Jung, Yoonmi;Jo, Deokjo;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.11
    • /
    • pp.1559-1564
    • /
    • 2012
  • Raisins (Thailand), dried mangos (Philippines), and dried figs (Iran) were gamma-irradiated (0~5 kGy), and their quality and detection characteristics were investigated. Microbiological characteristics were at safe levels when samples were irradiated at higher than 3 kGy. In color change after irradiation, dried mangoes were the most sensitive. Photostimulated luminescence (PSL) measurement was not applicable to dried fruits, showing negative or intermediate values for the irradiated samples. Thermoluminescence (TL) measurement was good for dried figs, exhibiting a glow curve in range of $150{\sim}200^{\circ}C$, where the signal intensity was dependent on the irradiation dose. Electron spin resonance (ESR) measurement was suitable for raisins and dried mangos, resulting in dose-dependent radiation-induced sugar radical signals.

Development of Dose Verification Method for In vivo Dosimetry in External Radiotherapy (방사선치료에서 투과선량을 이용한 체내선량 검증프로그램 개발)

  • Hwang, Ui-Jung;Baek, Tae Seong;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • The purpose of this study is to evaluate the developed dose verification program for in vivo dosimetry based on transit dose in radiotherapy. Five intensity modulated radiotherapy (IMRT) plans of lung cancer patients were used in the irradiation of a homogeneous solid water phantom and anthropomorphic phantom. Transit dose distribution was measured using electronic portal imaging device (EPID) and used for the calculation of in vivo dose in patient. The average passing rate compared with treatment planning system based on a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit was 95% for the in vivo dose with the homogeneous phantom, but was reduced to 81.8% for the in vivo dose with the anthropomorphic phantom. This feasibility study suggested that transit dose-based in vivo dosimetry can provide information about the actual dose delivery to patients in the treatment room.

A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF

Radiolysis of Oxygenated and Deoxygenated Glycylglycylglycine in Aqueous Solution and in the Solid State (酸素의 存在下와 無酸素下에서의 水溶液 및 固體 Glycylglycylglycine의 放射線分解)

  • Kang, Man-Sik
    • The Korean Journal of Zoology
    • /
    • v.13 no.3
    • /
    • pp.75-84
    • /
    • 1970
  • Gamma-radiolyses of oxygenated and deoxygenated glycylglycylclycine in aqueous solution and in the solid state are observed, with special regards to peptied bond rupture for elucidation of radiolytic mechanism of proteins, by means of chromatorgraphic separation of degradation products, spectrophotometric quantitation of carbonyl compounds, micro-titration of amide formation, infrared spectrophptometry, and ultraviolet spectrophotometry for evaluation of radiation damage. Essential difference of peptide bond rupture is observed in solution and in the solid state, being high in the former and negligible in the latter. On the other hand, the presence of and obsence of oxygen in solution during irradiation are not so significant with respect to peptide bond rupture, except the recombination of free-radicals produced in deoxygenated solution. Peptide bond rupture in solution is attributable to the mechanisms proposed by Garrison et al.; dehydrogenation followed by hydrolysis to yield acid amide and carbonyl function as found on the basis of radiolytic products. Peptide bond attack at $\\alpha$-carbon locus might be suggestive for irradiated solid but not significant in view of low degree of peptide bond rupture.

  • PDF