• Title/Summary/Keyword: Gamma Index

Search Result 451, Processing Time 0.032 seconds

MONITORING OF GAMMA-RAY BRIGHT AGN: THE MULTI-FREQUENCY POLARIZATION OF THE FLARING BLAZAR 3C 279

  • KANG, SINCHEOL;LEE, SANG-SUNG;BYUN, DO-YOUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.257-265
    • /
    • 2015
  • We present results of long-term multi-wavelength polarization observations of the powerful blazar 3C 279 after its γ-ray flare on 2013 December 20. We followed up this flare with single-dish polarization observations using two 21-m telescopes of the Korean VLBI Network. Observations carried out weekly from 2013 December 25 to 2015 January 11, at 22 GHz, 43 GHz, 86 GHz simultaneously, as part of the Monitoring Of GAmma-ray Bright AGN (MOGABA) program. We measured 3C 279 total flux densities of 22–34 Jy at 22 GHz, 15–28 Jy (43 GHz), and 10–21 Jy (86 GHz), showing mild variability of ≤ 50 % over the period of our observations. The spectral index between 22 GHz and 86 GHz ranged from −0.13 to −0.36. Linear polarization angles were 27°–38°, 30°–42°, and 33°–50° at 22 GHz, 43 GHz, and 86 GHz, respectively. The degree of linear polarization was in the range of 6–12 %, and slightly decreased with time at all frequencies. We investigated Faraday rotation and depolarization of the polarized emission at 22–86 GHz, and found Faraday rotation measures (RM) of −300 to −1200 rad m−2 between 22 GHz and 43 GHz, and −800 to −5100 rad m−2 between 43 GHz and 86 GHz. The RM values follow a power law with a mean power law index a of 2.2, implying that the polarized emission at these frequencies travels through a Faraday screen in or near the jet. We conclude that the regions emitting polarized radio emission may be different from the region responsible for the 2013 December γ-ray flare and are maintained by the dominant magnetic field perpendicular to the direction of the radio jet at milliarcsecond scales.

Supplementation of Conjugated Linoleic Acid with γ-Oryzanol for 12 Weeks Effectively Reduces Body Fat in Healthy Overweight Korean Women

  • Kim, Jung-Hee;Kim, Ok-Hyun;Ha, Yeong-Lae;Kim, Jeong-Ok
    • Preventive Nutrition and Food Science
    • /
    • v.13 no.3
    • /
    • pp.146-156
    • /
    • 2008
  • The enhancement of the human body fat reduction of conjugated linoleic acid (CLA) with the supplementation of $\gamma$-oryzanol (OZ) was investigated on overweight Korean women (n=51, BMI> 23). Subjects were divided into 4 groups of control, CLA, glyceride form of CLA (GCLA), and CLA plus OZ (CLA-OZ). The soft-gel capsule (500 mg) was used to deliver control (500 mg olive oil), CLA (500 mg CLA), GCLA (500 mg GCLA) and CLA-OZ (500 mg CLA plus 50 mg OZ). Three capsules were taken twice a day for 12 weeks. The CLA-OZ supplementation reduced 1.35% body fat that was 0.34% enhancement against CLA supplementation. As considered subject variations, CLA-OZ reduced body fat ranged from 7.9% to -2.7%, equivalent to 5.6 kg loss to 0.7 kg gain in body fat mass, against CLA. The CLA-OZ reduced body weight and body mass index (BMI), relative to control, but the reductions by CLA-OZ were not different from those by CLA and GCLA. All biochemical markers analyzed for safty were not significantly different within or between groups and were within the normal range. The CLA-OZ supplementation significantly reduced blood pressure, as compared to the supplementation of CLA, GCLA and control. These results suggest that OZ could be a useful ingredient to mix with CLA for the reduction of human body fat.

Calculation of Jaws-only IMRT (JO-IMRT) dose distributions based on the AAPM TG-119 test cases using Monte Carlo simulation and Prowess Panther treatment planning system

  • Luong, Thi Oanh;Duong, Thanh Tai;Truong, Thi Hong Loan;Chow, James CL
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4098-4105
    • /
    • 2021
  • The aim of this study is to calculate the JO-IMRT dose distributions based on the AAPM TG-119 using Monte Carlo (MC) simulation and Prowess Panther treatment planning system (TPS) (Panther, Prowess Inc., Chico, CA). JO-IMRT dose distributions of AAPM TG-119 were calculated by the TPS and were recalculated by MC simulation. The DVHs and 3D gamma index using global methods implemented in the PTW-VeriSoft with 3%/3 mm were used for evaluation. JO-IMRT dose distributions calculated by TPS and MC were matched the TG-119 goals. The gamma index passing rates with 3%/3 mm were 98.7% for multi-target, 96.0% for mock prostate, 95.4% for mock head-and-neck, and 96.6% for C-shape. The dose in the planning target volumes (PTV) for TPS was larger than that for the MC. The relative dose differences in D99 between TPS and MC for multi-target are 1.52%, 0.17% and 1.40%, for the center, superior and inferior, respectively. The differences in D95 are 0.16% for C-shape; and 0.06% for mock prostate. Mock head-and-neck difference is 0.40% in D99. In contrast, the organ curve for TPS tended to be smaller than MC values. JO-IMRT dose distributions for the AAPM TG-119 calculated by the TPS agreed well with the MC.

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

The Effects of Lonicerae Flos on bleomycin-induced lung fibrosis (금은화(金銀花)가 Bleomycin에 의한 폐섬유화(肺纖維化)에 미치는 영향(影響))

  • Lee Jae-Sung;Jung Hee-Jae;Jung Sung-Ki;Rhee Hyung-Goo
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.1
    • /
    • pp.71-80
    • /
    • 2004
  • Objective : Idiopathic Lung Fibrosis(IPF) is chronic fibrotic interstitial pneumonia. The pathogenesis is unclear. Lonicerae Flos is known to prevent the inflammation and reinforce the immune system. The effects of Lonicerae Flos on bleomycin-induced lung fibrosis is evaluated. Material and Methods: Lonicerae Flos extract was given to the Normal rats, control(bleomycin) rats everyday and treated(bleomycin and lonicerae flos) rats 21.0 mg per body weight 109 for 14 days. 14 days after, we observed the change of leukocyte count and percentage of IFN-gamma and IL-4 in BALF. and that of Semiquantative histological index(SHI). Results : Compared to control rats, Lonicerae Flos decreased leukocyte count(P<0.01) lymphocyte, neutrophil percentage(P<0.05), SHI(P<0.01), IFN-gamma and IL-4(P<0.05) in Treated rats. Otherwise, macrophage percentage was increased(P<0.01) in Treated rats. Conclusion : This study showed that Lonicerae Flos reduced the change of inflammatory cells and cytokines in bleomycin-induced lung fibrosis and reduced the fibrosis of tissue. And, we needed many other distinct researches on lung fibrosis.

  • PDF

Nonlinear optical properties of $TiO_{2}$ single crystal ($TiO_{2}$ 단결정의 비선형광학 특성)

  • 신재혁;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.3
    • /
    • pp.240-249
    • /
    • 1995
  • Rutile type of $TiO_{2}$ single crystal was grown by floating zone method in order to obtain the highly transparent and contamination-free single crystal. The linear refractive index of perpendicular and parallel to c-axis was measured as a function o f wavelength from 500 to 1000nm. The optical energy band gap was estimated as 2.99 eV from the absorption spectrum. The theoretical $\chi^{(3)}$} value of $TiO_{2}$ was discussed in comparison with that of $SiO_{2}$ quartz single crystal on the basis of semiempirical model. On the other hand, the second-hyperpolarizability, ${\gamma}({Ti}^{4+})$ was calculated in order to describe the effect of $Ti_{4}$ ion on the third order nonlinear optical properties.

  • PDF

The Effects of Astragali Radix on Bleomycin-induced Lung Fibrosis (황기가 C57BL/6J 생쥐의 Bleomycin유발 폐섬유화에 미치는 영향)

  • 이경희;정희재;정승기;윤유식;이형구
    • The Journal of Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.41-50
    • /
    • 2004
  • Backgrounds & Objectives: Many acute and chronic lung disorders with variable degrees of pulmonary inflammation and fibrosis are collectively referred to as interstitial lung diseases. Idiopathic pulmonary fibrosis (IPF) is one of several idiopathic interstitial pneumonias with the pathogenesis unclear. Astragali Radix is known to inhibit the Th2 immune response. The effects of Astragali Radix on bleomycin-induced lung fibrosis were evaluated. Materials and Methods: Astragali Radix extract was daily given to the normal rats, control (bleomycin) and treated (bleomycin and Astragali Radix extract, 24.0 mg/10g body weight) rats for 14 days. After 14 days, we observed the change of total leukocyte count and percentage, IFN-gamma and IL-4 in BALF (Bronchoalveolar lavage fluid), and of semiquantitative histological index (SHI). Results: Compared to the control group, Astragali Radix decreased total leukocyte count (p<0.05), lymphocyte (p<0.05), neutrophil (no significance) percentage, SHI (p<0.05), IFN-gamma and IL-4 (p<0.05). Otherwise, macrophage percentage was increased (p<0.01). Conclusion: This study showed that Astragali Radix reduced the incidence of inflammatory cells and cytokines and prevented the fibrosis of tissue in bleomycin-induced lung fibrosis rats.

  • PDF