• 제목/요약/키워드: Gamma (${\gamma}$)-ray

검색결과 1,793건 처리시간 0.025초

저선량 감마선과 전자선조사가 우육의 저장중 미생물 생육에 미치는 효과 (Effects of Low Dose Gamma Ray and Electron Beam Irradiation on Growth of Microorganisms in Beef During the Refrigerated Storage)

  • 김우선;정명섭;고영태
    • 한국축산식품학회지
    • /
    • 제18권3호
    • /
    • pp.232-239
    • /
    • 1998
  • This experiment was conducted to investigate radurization effects of gamma ray and electron beam irradiation at 1.5 and 3.0 kGy on beef steaks during 8 days of storage at 5$^{\circ}C$. Total bacteria count, psychrotrophs, mesophiles and thermophiles were analyzed at 2 days intervals. Nonirradiated beef steak was used a scontrol Total bacteria counts, psychrotrophs, mesophiles and thermophiles of the control samples showed 3.03∼4.72 logCFU / g at 0 day and increased to 7.67∼10.90 logCFU / g during 8 days storage except thermophiles. Total bacteria counts, psychrotrophs and mesophiles of beef steaks at 8 days were significantly (p<0.05) decreased to 3.61∼5.43 logCFU / g by gamma ray and to 3.83∼7.02 logCFU / g by electron beam irradiation at 1.5 and 3.0 kGy. Thermophiles of all irradiated samples at any dose were not detectable through 8 days storage. These results suggested that both gamma ray and electron beam irradiation were effective to extend lag phase of bacterial growth of refrigerated beef. Gamma ray irradiation was better than electron beam irradiation in terms of radurization effects of beef.

  • PDF

APPARENT INWARD MOTION OF THE PARSEC-SCALE JET IN THE BL LAC OBJECT OJ287 DURING THE 2011-2012 γ-ray FLARES

  • SAWADA-SATOH, S.;AKIYAMA, K.;NIINUMA, K.;NAGAI, H.;KINO, M.;D'AMMANDO, F.;KOYAMA, S.;HADA, K.;ORIENTI, M.;HONMA, M.;SHIBATA, K.M.
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.429-432
    • /
    • 2015
  • We present a kinematic study of the parsec-scale radio jet in OJ 287, one of the most studied BL Lac objects, during ${\gamma}$-ray flares, to explore the relation between parsec-scale radio jet activity and ${\gamma}$-ray emission. The 22-GHz light curve of OJ 287 show three obvious flare events around 2011 May, 2011 October, and 2012 March. The second radio flare occurred during the ${\gamma}$-ray flaring period, and the third radio flare seemed to precede the ${\gamma}$-ray flare by one month. One jet component moved outward with respect to the core component with an apparent superluminal speed (~ 11c) from 2010 November to 2011 November. Then it changed direction, moving apparently inward in 2011 November, when the ${\gamma}$-ray flare occurred. The observed apparent inward motion of the jet at 22 GHz could be caused by a new jet component, unresolved at 22 GHz, in the innermost region.

Differential Modulation of Volatile Constituents in Artemisia princeps and Artemisia argyi Plants after Gamma Ray or Electron Beam Irradiation

  • Kim, Ji Hong;Cho, Eun Ju;Lee, Min Hee;Kim, Ji Eun;Chung, Byung Yeoup;Kim, Tae Hoon;Kim, Jin-Hong
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.17-21
    • /
    • 2012
  • The effects of gamma ray or electron beam irradiation on herbaceous medicinal plants were investigated in terms of the composition of volatile constituents using the aerial parts or leaves of Artemisia princeps Pamp. cv. Ganghwayakssuk and Artemisia argyi cvs. Namhaeyakssuk and Hwanghaessuk. The composition of volatile constituents in leaves was clearly distinguishable among the three Artemisia cultivars. However, the relative proportions of the major volatile constituents such as 1,8-cineole, ${\alpha}$-pinene, camphene, santolina triene, and artemesia triene, were similarly changed in two or three cultivars by gamma ray or electron beam irradiation. In particular, the proportion of 1,8-cineole was increased up to 1.29- to 1.71-fold in the three cultivars after irradiation with gamma ray. These results suggest that gamma ray or electron beam irradiation can be applied to modulate the composition of volatile constituents in the leaves of Artemisia plants.

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Monte Carlo simulations for gamma-ray spectroscopy using bismuth nanoparticle-containing plastic scintillators with spectral subtraction

  • Taeseob Lim ;Siwon Song ;Seunghyeon Kim ;Jae Hyung Park ;Jinhong Kim;Cheol Ho Pyeon;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3401-3408
    • /
    • 2023
  • In this study, we used the Monte Carlo N-Particle program to simulate the gamma-ray spectra obtained from plastic scintillators holes filled with bismuth nanoparticles. We confirmed that the incorporation of bismuth nanoparticles into a plastic scintillator enhances its performance for gamma-ray spectroscopy using the subtraction method. The subtracted energy spectra obtained from the bismuth-nanoparticle-incorporated and the original plastic scintillator exhibit a distinct energy peak that does not appear in the corresponding original spectra. We varied the diameter and depth of the bismuth-filled holes to determine the optimal hole design for gamma-ray spectroscopy using the subtraction method. We evaluated the energy resolutions of the energy peaks in the gamma-ray spectra to estimate the effects of the bismuth nanoparticles and determine their optimum volume in the plastic scintillator. In addition, we calculated the peak-to-total ratio of the energy spectrum to evaluate the energy measuring limit of the bismuth nanoparticle-containing plastic scintillator using the subtraction method.

Explainable radionuclide identification algorithm based on the convolutional neural network and class activation mapping

  • Yu Wang;Qingxu Yao;Quanhu Zhang;He Zhang;Yunfeng Lu;Qimeng Fan;Nan Jiang;Wangtao Yu
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4684-4692
    • /
    • 2022
  • Radionuclide identification is an important part of the nuclear material identification system. The development of artificial intelligence and machine learning has made nuclide identification rapid and automatic. However, many methods directly use existing deep learning models to analyze the gamma-ray spectrum, which lacks interpretability for researchers. This study proposes an explainable radionuclide identification algorithm based on the convolutional neural network and class activation mapping. This method shows the area of interest of the neural network on the gamma-ray spectrum by generating a class activation map. We analyzed the class activation map of the gamma-ray spectrum of different types, different gross counts, and different signal-to-noise ratios. The results show that the convolutional neural network attempted to learn the relationship between the input gamma-ray spectrum and the nuclide type, and could identify the nuclide based on the photoelectric peak and Compton edge. Furthermore, the results explain why the neural network could identify gamma-ray spectra with low counts and low signal-to-noise ratios. Thus, the findings improve researchers' confidence in the ability of neural networks to identify nuclides and promote the application of artificial intelligence methods in the field of nuclide identification.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권4호
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구 (The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector)

  • 황영관;이남호;이승민
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.197-203
    • /
    • 2015
  • 전 세계적으로 전력생산을 위해 원전 증설이 지속적으로 증가하고 있으며 이에 따라 노후 원전에 대한 해체 및 원전사고에 대한 관심이 증가하고 있다. 원전 사고 시 발생되는 감마선원의 누출은 신속하고 정확한 탐지해야 그 피해를 최소화 시킬 수 있다. 기 개발된 장비는 선원에 대한 방향정보만을 나타내고 있어 정확한 공간상의 분포를 알 수 없다. 본 논문에서 개발한 스테레오 감마선탐지장치는 누출된 감마선원에 대한 분포를 측정할 수 있도록 구현하고 거리탐지를 위한 알고리즘을 적용하였다. 거리탐지를 위하여 스테레오 보정을 LED광과 보정패턴을 사용하여 진행하였고, LED 광원과 감마선원을 대상으로 성능시험을 진행하였다. 성능시험 결과 두 실험에서 5%이하의 오차를 갖게 됨을 확인하였다. 본 논문의 결과는 향후 고속 경량화 된 감마선 영상화 장치 개발을 위한 자료로 활용될 것이다.

고 선량율 감마선 조사에 따른 렌즈의 열화 (A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation)

  • 조재완;이준구;허섭;구인수;홍석붕
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

Effects of Low Dose Gamma Radiation on the Root Growth of Soybean Cultivars

  • Yoon, Young-Man;Cho, Hyung-In;Chang, Sung-Hee;Kim, Nam-Bum;Kim, Jae-Sung;Kim, Jeong-Gyu
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.394-400
    • /
    • 2000
  • ${\gamma}-Radiation$ at very low doses frequently has a stimulating or hormetic effect on the growth of organism. Effects of low dose ${\gamma}-ray$ irradiation on the root growth of soybean cultivars were investigated and hormetic effects by environmental conditions were compared with the occurrence of increased economic yield, seeds of cultivars were irradiated with the dose of $0.5{\sim}20Gy$ and cultivated in growth chamber controling temperature, humidity, light, greenhouse and field respectively. To understand hormetic effect on root growth of cultivars and the difference of hormetic effect by cultivation environment, harvested root of soybean cultivars were scanned with image file, and root surface area, root length, root average diameter etc. were examined by WinRhizo program. Also, dry weight of cultivars was examined. Root growth and dry weight of soybean cultivars showed apparently hormetic effect at cultivation of growth chamber condition. In field experiment executed for whole life cycle, yields of pea were not different significantly in each ${\gamma}-ray$ irradiated cultivars but weight of one hundred peas increased in whole ${\gamma}-ray$ irradiated cultivars. Increment of yield was assumed to be induced through shortening of maturing stage caused by ${\gamma}-ray$ hormesis in early growth stage.

  • PDF