• Title/Summary/Keyword: Galvanic

Search Result 351, Processing Time 0.023 seconds

A Study on Visual and Auditory Emotion under Color and Music Stimuli (색과 음악 자극에 의한 시청각 감성지표에 관한 연구)

  • 김남균;김지훈;유충기
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.539-546
    • /
    • 1998
  • The purpose of this study is to estimate human emotion quantitatively under colors and music stimuli and to examine the for correlation between color and music sensibility. Physiological signals(electroencephalogram, electrocardiogram, Galvanic skin conductivity and respiration rate) were measured to compare color with music sensibilities. The personality of the subject were investigated using factor analysis and semantic differential method of 20 items(7 interval scaled). The results showed that red, yellow and violets color provoked active and exciting senses mainly as dance, rock and blues music. While blue, cyan and pink colors ware involved in tranquil and resting emotions deeply as classic and ballade music.

  • PDF

Production of concrete paving blocks using electroplating waste - Evaluation of concrete properties and solidification/stabilization of waste

  • Sgorlon, Juliana Guerra;Tavares, Celia Regina Granhen;Franco, Janaina de Melo
    • Advances in environmental research
    • /
    • v.3 no.4
    • /
    • pp.337-353
    • /
    • 2014
  • The determination of the effectiveness of the immobilization of blasting dust (waste generated in galvanic activities) in cement matrix, as well of mechanical, physical and microstructural properties of concrete paving blocks produced with partial replacement of cement was the objective of this work. The results showed that blasting dust has high percentage of silica in the composition and very fine particle size, characteristics that qualify it for replacement of cement in manufacturing concrete blocks. The replacement of Portland cement by up to 5% residues did not cause a significant loss in compressive strength nor increase in water absorption of the blocks. Chemical tests indicated that there is no problem of leaching or solubilization of contaminants to the environment during the useful life of the concrete blocks, since the solidification/stabilization process led to the immobilization of waste in the cement mass. Therefore, the use of blasting dust in the manufacture of concrete paving blocks is promising, thus being not only an alternative for proper disposal of such waste as well as a possibility of saving raw materials used in the construction industry.

A Study on Underwater Electro-magnetic Signature Prediction Due to Hull Corrosion of a Naval Ship (함정의 선체 부식에 의한 수중 전자기 신호 예측에 관한 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Ju, Hae-Sun;Jeon, Jae-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.177-185
    • /
    • 2012
  • Corrosion currents flow through the seawater due to the different electrochemical potential between a hull and a propeller under the draft line of ship. Additionally, in order to protect the hull and other sensitive anodic parts of the ship from corrosion, the corrosion protection system, called impressed current cathodic protection(ICCP) equipment has been installed in most naval ships. Those currents could be harmful to the electromagnetic silencing of the naval ship because sea mines are triggered by even a feeble field value. In this paper, we described electric and corrosion related magnetic fields by ship's galvanic corrosion and a corrosion protection system, and prediction results of electric and corrosion related magnetic fields at any depth for the model ship.

Classification of Grid Connected Transformerless PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families

  • Ozkan, Ziya;Hava, Ahmet M.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.256-267
    • /
    • 2015
  • Grid-connected transformerless photovoltaic (PV) inverters (TPVIs) are increasingly dominating the market due to their higher efficiency, lower cost, lighter weight, and reduced size when compared to their transformer based counterparts. However, due to the lack of galvanic isolation in the low voltage grid interconnections of these inverters, the PV systems become vulnerable to leakage currents flowing through the grounded star point of the distribution transformer, the earth, and the distributed parasitic capacitance of the PV modules. These leakage currents are prohibitive, since they constitute an issue for safety, reliability, protection coordination, electromagnetic compatibility, and module lifetime. This paper investigates a wide range of multi-kW range power rating TPVI topologies and classifies them in terms of their leakage current attributes. This systematic classification places most topologies under a small number of classes with basic leakage current attributes. Thus, understanding and evaluating these topologies becomes an easy task. In addition, based on these observations, new topologies with reduced leakage current characteristics are proposed in this paper. Furthermore, the important efficiency and cost determining characteristics of converters are studied to allow design engineers to include cost and efficiency as deciding factors in selecting a converter topology for PV applications.

Isolated DC/DC Converter with Very Wide Input Voltage Ranges for Emergency Power Back-up System(EPBS) (비상전원 공급장치를 위한 넓은 입력전압 범위를 갖는 절연형 DC/DC 컨버터)

  • Chae, Hyung-Jun;Kim, Kyoung-Dong;Oh, Hyung-Rock;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.334-341
    • /
    • 2011
  • This paper presents a design and implementation of DC/DC converter with very wide input voltage ranges for EPBS whose input voltage is from 30V to 400V and output voltage is 48V. This converter is comprised of two stages that one is for control and the other is for only galvanic isolation. The proposed converter uses the hard-switched buck-boost topology for control purpose and soft-switched LLC resonant converter for isolation. The proposed converter has been verified with 300W design.

Isolated Bidirectional CLLC Resonant Converter using Digital Control for LVDC Distribution System (디지털로 제어되는 저압 직류 배전용 절연형 양방향 CLLC 공진형 컨버터)

  • Jung, Jee-Hoon;Kim, Ho-Sung;Ryu, Myung-Hyo;Kim, Jong-Hyun;Kim, Tae-Jin;Baek, Ju-Won
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.379-380
    • /
    • 2012
  • A bidirectional full-bridge CLLC resonant converter using a digital control method is proposed for a LVDC power distribution system. This converter can operate under high power conversion efficiency since the CLLC resonant network has soft switching capability for primary switches and output rectifiers. In addition, the power conversion efficiency of any directions is exactly the same as each other because of the symmetric structure of the converter. Intelligent digital control methods are proposed to regulate output voltage under any power flow directions. A 5kW prototype converter was designed for a high-frequency galvanic isolation of 380V dc buses using a digital signal processor to verify the performance of the proposed topology and algorithms.

  • PDF

Corrosion analysis of the duplex aluminum alloys (듀플렉스 알루미늄 합금의 내식성 분석)

  • Choi, In Kyu;Kim, Si Myeong;Kim, Sang Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.5
    • /
    • pp.227-232
    • /
    • 2015
  • Corrosion characteristic of the duplex Al-Mg-Si alloys with low, commercial and high solute contents were studied using an anodic polarization test in 1M NaCl solution at room temperature. Polarization range condition of the experiment were form .0.3V to .1.3V with a 0.2 mV scanning speed. The exchange current density means corrosion rate of the low solute alloy was low as about $16.29{\mu}A/cm^2$, and that of the high solute alloy was high as $84.92{\mu}A/cm^2$. The difference was mainly attributed to the inter-granular precipitates $Mg_2Si$ and Si which could make a galvanic corrosion on the aluminum base. The amount of precipitates was greater in high solute alloy at mainly in grain boundary. While, the extruded alloys had better corrosion resistance than the cast alloy because the silicon precipitates become coarse during the extrusion process.

Continuous and Pulsed Laser Induced Copper Deposition on Silicon(Si) from Liquid Electrolyte (전해질 용액내의 실리콘 단결정 표면에서 레이저로 유기되는 구리 침착)

  • 유지영;안창남;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.50-54
    • /
    • 1992
  • Maskless depositon of copper onto n-doped and p-doped Si in an aqueous copper sulfate solution is investigated. On p-doped Si substrates, microscopic $(~10\mu\textrm{m}$) copper spots are deposited by illuminating continuous wave $Ar^+$ laser beam of wavelength 514.5 nm. Copper deposition on n-doped Si substrates is also achieved by shinning second harmonic pulses $(pulse width~25 nsec, \lambda=530 nm)$ of a passively Q-switched Nd:YAG laser. The observed deposition is attributed to the electric field resulting from the Galvanic potential of a semiconductor-electrolyte junction.

  • PDF

Preliminary Study of the Measurement of Foreign Material in Galvanic Corrosion Using Laser Ultrasonic

  • Hong, Kyung Min;Kang, Young June;Park, Nak Kyu;Choi, In Young
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.323-327
    • /
    • 2013
  • A laser ultrasonic inspection system has the advantage of nondestructive testing. It is a non-contact mode using a laser interferometer to measure the vertical displacement of the surface of a material caused by the propagation of ultrasonic signals with the remote ultrasonic generated by laser. After raising the ultrasonic signal with a broadband frequency range using a pulsed laser beam, the laser beam is focused to a small point to measure the ultrasonic signal because it provides an excellent measurement resolution. In this paper, foreign materials are measured by a non-destructive and non-contact method using the laser ultrasonic inspection system. Mixed foreign material on the corroded part is assumed and the laser ultrasonic experiment is conducted. An ultrasonic wave is generated by pulse laser from the back of the specimen and an ultrasonic signal is acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer (CFPI). The characteristic of the ultrasonic signal of existing foreign material is analyzed and the location and size of foreign material is measured.

Prospects on the Use of Corrosion Rate Measurement Method for Stainless Steel (스테인리스 강의 부식 측정방법의 이용과 전망)

  • Choi, Yongseon;Lee, Jaewon;Park, Eunoak;Lee, Kiyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.294-301
    • /
    • 2021
  • As the number of cases of performance degradation owing to corrosion of plant during processing in industries increases, the cost of maintaining industrial factory is increasing year by the year. Most of the materials of the facilities are consist of stainless steel (SS) such as austenite SS, ferrite SS, martensite SS, and duplex SS. Among them austenite SS is cheap and has excellent corrosion resistance and heat resistance. Corrosion is the consumption and change of metals by altering chemical and electrical reactions. The types of SS corrosion include pitting corrosion, crevice corrosion, galvanic corrosion, stress corrosion cracking, and thermal corrosion. The corrosion of SS is not only investigated various environmental factors but also the measurement of the corrosion rate. Therefore, it aims to understand comprehensive corrosion rates in various environments using qualitative, quantitative and electrochemical methods.