• 제목/요약/키워드: Galactose Sensor

검색결과 4건 처리시간 0.023초

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권3호
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발 (Development of electrochemical biosensor for determination of galactose)

  • 박갑수;조순삼;권덕;이재선;차근식;남학현
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.393-399
    • /
    • 2007
  • 본 연구에서는 갈락토오즈의 현장검사(point-of-care testing, POCT)를 위한 일회용 갈락토오즈 바이오센서 개발에 관해 논하고자 한다. Galactose oxidase(GAO)와 horseradish peroxidase(HRP) 두 효소를 0.05 M phosphate 완충용액에 용해시킨 후 스크린 프린팅(screen printing) 방법으로 제작한 전극위에 고정화하여 센서를 제작하였다. 이렇게 제작된 센서를 이용하여 $100{\mu}L$ 이하의 시료를 이용하여 갈락토오즈를 90초 이내에 측정하였다. 전극에서의 반응을 최적화하기 위하여 GAO 효소가 가장 우수한 활성을 나타내는 pH 7.0 완충용액을 이용하여 GAO와 HRP 효소를 1:1로 고정화하고, 1mM 1,1'-ferrocene-dimethanol 전자전달매개체를 도입하여 센서를 제작하였다. 유리 탄소전극의 경우 100 mV (vs Ag/AgCl), 스크린 프린트된 전극의 경우 -100 mV(vs Ag/AgCl)의 인가전압을 적용하였다. 본 연구에 의해 개발된 센서는 $0{\sim}400{\mu}M$의 갈락토오즈 농도에 대하여 우수한 직선성($r^2$ = 0.997, S/N = 3)을 나타내었고 낮은 인가전압을 적용하여 갈락토오즈를 측정하므로, ascorbic acid, uric acid 그리고 acetaminophen과 같은 방해물질의 영향을 최소화 할 수 있었다. 또한 갈락토오즈 표준 용액에 대하여 만족할 만한 재현성을 나타내었다(CV = 5%).

Development of Single-layer Glucose Sensor Using GDH-FAD (Glucose Dehydrogenase Flavin Adenine Dinucleotide)

  • Kye, Ji-Won;Lee, Young-Tae
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.156-159
    • /
    • 2018
  • We developed a glucose sensor using glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD). The structure of the three-layer glucose sensor was simplified, in which a single-layer design was used to lower the unit cost, and GDH-FAD was used to increase the measurement reliability. GDH-FAD has less impact on the 20 interfering substances that affect blood glucose measurement, such as galactose and maltose compared to glucose oxidase (GOD), and is not affected by the oxygen saturation; therefore, it is possible to measure both arterial or venous blood and thus less susceptibility to hematocrit. In this study, we developed a single-layer glucose sensor strip with low hematocrit effect using the GDH-FAD enzyme, and measured and evaluated the performance.

기포계수식 발효가스 발생량 계측시스템의 개발 (Development of Gas Production Measurement System by Bubble Counting during Fermentation)

  • 이영진;전재근
    • 한국식품과학회지
    • /
    • 제26권3호
    • /
    • pp.195-198
    • /
    • 1994
  • Yeast 발효공정에서 발생되는 가스량을 전자적으로 monitoring 할 수 있는 새로운 기포수 계측 쎈서를 설계, 제작하였다. 본 기포쎈서는 기체를 발생하는 발효공정에 적용할 수 있으며 공정의 상태와 환경에 아무런 변화를 주지 않도록 설계하였다. 그 구조는 가스포집부, 기포형성부, 전자식 기포감지부와 컴퓨터 접속장치로 구성하였다. 기포 계측부는 photo-interrupter카 counter IC 등을 사용하였다. 제작된 쎈서와 컴퓨터 시스템은 효모 배양공정에 활용하여 발효진행과정을 자동적으로 monitoring 하는데 성공하였으며 발효공정에서 발생된 기포수의 값으로 작성된 가스발생량 곡선은 효모의 생육곡선의 양상과 매우 유사한 모양을 보였으며 배양액의 기질영양원이 달리한 발효공정을 monitering한 결과 기질이용 특성도 정확하게 표현할 수 있었다.

  • PDF