• 제목/요약/키워드: Gait phase

검색결과 311건 처리시간 0.024초

Difference in Gait Characteristics During Attention-Demanding Tasks in Young and Elderly Adults

  • In Hee Cho;Seo Yoon Park;Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • 제35권3호
    • /
    • pp.64-70
    • /
    • 2023
  • Purpose: This study investigated the influence of attention-demanding tasks on gait and measured differences in the temporal, spatial and kinematic characteristics between young healthy adults and elderly healthy adults. Methods: We recruited 16 healthy young adults and 15 healthy elderly adults in this study. All participants performed two cognitive tasks: a subtraction dual-task (SDT) and working memory dual-task (WMDT) during gait plus one normal gait. Using the LEGSys+ system, knee and hip-joint kinematic data during stance and swing phase and spatiotemporal parameter data were assessed in this study. Results: In the elderly adult group, attention-demanding tasks with gait showed a significant decrease in hip-joint motion during the stance phase, compared to the normal gait. Step length, stride length and stride velocity of the elderly adult group were significantly decreased in WMDT gait compared to normal gait (p<0.05). In the young adult group, kinematic data did not show any significant difference. However, stride velocity and cadence during SDT and WMDT gaits were significantly decreased compared to those of normal gait (p<0.05). Conclusion: We determined that attention-demanding tasks during gait in elderly adults can induce decreased hip-joint motion during stance phase and decreased gait speed and stride length to maintain balance and prevent risk of falling. We believe that understanding the changes during gait in older ages, particularly during attention-demanding tasks, would be helpful for intervention strategies and improved risk assessment.

대퇴골 회전방지보조기를 착용한 트레드밀 보행훈련이 뇌성마비 아동의 하지배열 및 보행에 미치는 영향: 단일그룹 반복측정 연구 (The Effects of Treadmill Gait Training with Flexible Derotator of Femur Orthosis on Postural Alignment of Lower Extremities and Gait in Children with Cerebral Palsy: Single Group Rpeated Measure Design)

  • 유현영;김선엽;장현정
    • 대한물리의학회지
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the effects of flexible derotator of femur orthosis (FDO) during treadmill gait training on the quadriceps-angle (Q-angle), lateral pelvic tilt, gait speed, and number of steps in children with cerebral palsy. METHODS: Seven children with cerebral palsy who had rotational deformity of the lower extremities participated in this study. We used single group repeated measure design. The procedure consisted of baseline phase, intervention phase, and post-intervention phase. The baseline phase consisted of stretching and strengthening exercise and treadmill gait training without FDO. The treatment phase not only included the same procedures as those for baseline, but also included FDO during treadmill gait training. Postural alignment of the lower extremities was assessed with the Q-angle, and lateral pelvic tilt using the Dartfish software program. A 10-m walk test was used to evaluate gait speed and number of steps. RESULTS: For postural alignment, there was significant differences after the application of FDO (p<.05). For gait ability, there was significant differences in all phases (p<.01). CONCLUSION: These finding suggest that the application of FDO during treadmill gait training had a positive effect on the improvement of postural alignment and gait ability in children with cerebral palsy having rotational deformity.

전자-기계식 클러치를 이용한 장하지 보조기용 무릎관절 자동 제어 장치의 개발 (Development of the Automatic Knee Joint Control System for a Knee-Ankle-Foot Orthosis Using an Electromechanical Clutch)

  • 이기원;강성재;김영호;조강희
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권4호
    • /
    • pp.359-368
    • /
    • 2001
  • A new knee-ankle-foot-orthosis(KAFO) which uses an automatically-controlled electromechanical wrap spring clutch for the knee joint was developed in the present study. It was found that the output voltage from the foot switches of the developed KAFO was proportionally increased with respect to the applied load. The output voltage from the infrared sensor also decreased as the knee flexion angle increased. The knee joint system for the new KAFO weighs only 780g lighter than any other commercially available developed system. In addition, the solenoid reduces the reaction time for the automatic control of the knee joint. The static torque of the clutch was measured for three persons, and it satisfied the normal knee extension moment during the pre-swing. Three-dimensional gait analyses for three different gait patterns (normal gait, locked-knee gait, controlled-knee gait) from five normal subjects were conducted. Controlled-knee gait showed the maximum knee flexion angle of 40.56$\pm9.55^{\circ}$ and the maximum knee flexion moment of 0.20$\pm$0.07Nm/kg at similar periods in the normal gait. Our KAFO system satisfies both stability during stance phase and free knee flexion during the swing phase at the proper period during the gait cycle. Therefore, our KAFO system would be very useful in various low extremity orthotic applications.

  • PDF

정상 성인의 무게 부하 보행이 관절 모멘트의 변화에 미치는 영향 (The Changes of Joint Moments According to Weight Loading Gait on Normal Adults)

  • 정형국
    • 대한물리치료과학회지
    • /
    • 제10권2호
    • /
    • pp.53-61
    • /
    • 2003
  • The purposes of this study were to describe and compare pint moments according to 6 types of gait methods during free speed. 15 volunteers(7 male, 8 female: mean age = 23.33 yrs.) participated and performed 6 types of gait methods. From the 3 types of pint moments of lower extremities(hip, knee, ankle and foot), the following results were made: 1. In left hip pint, the flexion-extension moment was not significantly different, but the adduction-abduction moment and rotation moment were showed different curves during stance phase. 2. In left knee pint, the flexion-extension moment was not significantly different, but the varus-valgus moment and rotation moment were showed different curves during stance phase. 3. In left ankle and foot the dorsiflexion-plantarflexion moment was not significantly different but the varus-valgus moment and rotation moment were showed different curves during stance phase. In conclusion, because weight loading gait with 10-20% of body weight were normal gait patterns, It was inferred that all weight loading gaits did not indicate noxious reactions of human body.

  • PDF

Correlation between Gait Speed and Velocity of Center of Pressure Progression during Stance Phase in the Older Adults with Cognitive Decline: A Pilot Study

  • Seon, Hee-Chang;Lee, Han-Suk;Ko, Man-Soo;Park, Sun-Wook
    • 대한물리의학회지
    • /
    • 제15권4호
    • /
    • pp.67-74
    • /
    • 2020
  • PURPOSE: The progression of the center of pressure (COP) velocity of the stance phase may have important roles for predicting gait speed in older adults with cognitive decline. This study was conducted to identify the correlation between gait speed and the velocity of COP progression during the stance phase in older adults with cognitive decline. METHODS: Forty adults aged 65 years or older (twenty participants without cognitive decline, 20 participants with cognitive decline) were recruited. The COP progression velocity was measured using an F-scan pressure-sensitive insole system. The stance phase was divided into four sub-stages. (loading response, mid-stance, terminal stance, and pre-swing). Gait speed, double support phase, and cadence were also measured. Correlations and multiple regression analyses were performed. RESULTS: Gait speed was associated with the COP progression velocity in midstance (r = .719, p < .05), cadence (r = .719, p < .05) and the COP progression velocity in loading response velocity (r = .515, p < .05) in older adults with cognitive decline. However, no correlation was found in older adults without cognitive decline. In multiple regression analysis using gait speed as a dependent variable, the COP progression velocity in midstance and cadence were significant predictors of gait speed, with the COP progression velocity being the most significant predictor. CONCLUSION: The COP progression velocity is an important factor for predicting gait speed in older adults with cognitive decline, suggesting that the cognitive function influences gait speed and the velocity of COP progression.

증감부호기를 이용한 순간 대칭비 기반 보행 불균형 평가 (Gait Imbalance Evaluation Algorithm based on Temporal Symmetry Ratio using Encoder)

  • 김서준;김유현;심현민;윤광섭;이상민
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권1호
    • /
    • pp.8-13
    • /
    • 2014
  • In this paper, the gait imbalance evaluation algorithm based on temporal symmetry ratio using encoder is proposed. The device is attached to the hip joint in order to measure the angle during the normal gait. Using an angle data, the stance phase and swing phase was determined. And the value of TSR(temporal symmetry ratio) was calculated by stance phase and swing phase of gait cycle. For the comparative experiment, the conventional method of the foot pressure was measured at the same conditions. The results of statistical analysis, there was a significant difference (p < 0.05) when using encoder. The gait imbalance analysis using encoder is effective in determining the imbalance than using the existing method of pressure.

Clinical Feasibility of Wearable Robot Orthosis on Gait and Balance Ability for Stroke Rehabilitation: A Case Study

  • Shin, Young-Il;Yang, Seong-Hwa;Kim, Jin-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제27권2호
    • /
    • pp.124-127
    • /
    • 2015
  • Purpose: The emphasis on gait rehabilitation after stroke depends on training support through the lower limbs, balance of body mass over the changing base of support. However, muscle weakness, lack of control of lower limb, and poor balance can interfere with training after stroke. For this case study report, a wearable robot orthosis was applied to stroke patients in order to verify its actual applicability on balance and gait ability in the clinical field. Methods: Two stroke patients participated in the training using the wearable robot orthosis. Wearable robot orthosis provides patient-initiated active assistance contraction during training. Training includes weight shift training, standing up and sitting down, ground walking, and stair up and down Training was applied a total of 20 times, five times a week for 4 weeks, for 30 minutes a day. Gait ability was determined by Stance phase symmetry profile, Swing phase symmetry profile, and velocity using the GAITRite system. Balance ability was measured using the Biodex balance system. Results: Subjects 1, 2 showed improved gait and balance ability with mean individual improvement of 72.4% for velocity, 19.4% for stance phase symmetry profile, 9.6% for swing phase symmetry profile, and 13.6% for balance ability. Conclusion: Training utilizing a wearable robot orthosis can be useful for improvement of the gait and balance ability of stroke patients.

비평탄 지형에서 사각 보행 로봇의 고장후 보행 (Post-Failure Walking of Quadruped Robots on a Rough Planar Terrain)

  • 양정민;박용국
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권9호
    • /
    • pp.547-555
    • /
    • 2005
  • A fault-tolerant gait of multi-legged robots with static walking is a gait which can maintain gait stability and continue its walking against an occurrence of a leg failure. This paper proposes fault-tolerant gait planning of a quadruped robot walking over a rough planar terrain. The considered fault is a locked joint failure, which prevents a joint of a leg from moving and makes it locked in a known position. In this Paper, two-phase discontinuous gaits are presented as a new fault-tolerant gait for quadruped robots suffering from a locked joint failure. By comparing with previously developed one-phase discontinuous gaits, it is shown that the proposed gait has great advantages in gait performance such as the stride length and terrain adaptability. Based on the two-phase discontinuous gait, quasi follow-the-leader(FTL) gaits are constructed which enable a quadruped robot to traverse two-dimensional rough terrain after an occurrence of a locked joint failure. During walking, two front legs undergo the foot adjustment procedure for avoiding stepping on forbidden areas. The Proposed wait planning is verified by using computer graphics simulations.

여성 노인의 자세 정렬과 시공간 보행 변수 사이의 연관성 (Relationship Between the Postural Alignments and Spatio-temporal Gait Parameters in Elderly Woman)

  • 김성현;신호진;서혜림;정경심;조휘영
    • 대한물리의학회지
    • /
    • 제15권3호
    • /
    • pp.117-125
    • /
    • 2020
  • PURPOSE: Aging causes changes in the postural alignment and gait due to changes in the nervous and musculoskeletal systems. On the other hand, the relationship between the changes in posture alignment and gait is unclear. This study examined the relationship between the postural alignment and spatiotemporal gait parameters in Korean elderly women. METHODS: Thirty-two-healthy elderly women participated in this study. All subjects were assessed for their posture alignment and gait ability. Stepwise multiple linear regression was performed to determine to what extent the postural alignments could explain the spatiotemporal gait parameters. RESULTS: Coronal head angle was moderately correlated with the velocity (r = -.51), normalized velocity (r = -.46) and gait-stability ratio (r = .58) (p < .05). The trunk angle was moderately correlated with the normalized velocity (r = -.32) and gait-stability ratio (r = .32) and weakly correlated with the velocity (r = -.28) (p < .05). The coronal shoulder angle was moderately correlated with the swing phase (r = -.57), stance phase (r = .56), single limb stance (r = -.56) and double limb stance (r = .51) (p < .05). The coronal head angle and trunk angle accounted for 36% of the variance in velocity, 33% variance in normalized velocity and 46% variance in the gait-stability ratio (p < .05). The coronal shoulder angle accounted for 32% variance in the swing phase, 32% variance in the stance phase, 31% variance in the single limb stance and 26% variance in the double limb stance (p < .05). CONCLUSION: Changes in posture alignment in elderly women may serve as a biomarker to predict a decrease in walking ability due to physical aging.

Comparison of Plantar Pressure and Contact Time on Gait between the Korean Young and the Elderly Women

  • Kim, Hee-Eun
    • 한국의류산업학회지
    • /
    • 제19권5호
    • /
    • pp.602-607
    • /
    • 2017
  • This study was undertaken to compare the gait characteristics between the Korean elderly and young adults, we measured the plantar pressure and contact time of gait with barefoot along a walkway at their preferred walking speed. The results indicate that older people exhibited significantly less plantar pressure than young adult in all 3 regions (FF, MF and RF) and significantly less time % on the initial contact phase (ICP), forefoot push-off phase (FFPOP) and significantly more % forefoot contact phase (FFCP) and foot flat phase (FFP). The converted plantar pressure value to percentage, it showed more pressure in forefoot (FF) in the elderly person than the young adults. It could be explained that the forward shifting in plantar pressure are associated with a more flexed posture of elderly such as actual stabilizing fearrelated adaptations. Longer total foot contact time in the elderly means that the old people show the decreased gait velocity. In other words, lower velocity was found to be associated with pre-existing fear of falling. With longer contact time and slower stepping movement, the elderly become more unstable. With these findings, it could be confirmed that there were significant changes in foot characteristics which contribute to alter the plantar pressure and contact time during gait with advancing age. Further research is required to establish possible links to risk of falling and development of footwear in the elderly adults.