• Title/Summary/Keyword: Gait Characteristics

Search Result 260, Processing Time 0.023 seconds

Gait Recovery Characteristic According to the Injury Aspect of Descending Motor Pathway in a Chronic Stroke Patient: a Case Study

  • Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.326-331
    • /
    • 2022
  • Purpose: The stroke patients have gait dysfunction due to impaired neural tracts; corticospinal tract (CST), corticoreticular pathway (CRP), and vestibulospinal tract (VST). In this study, we investigated characteristics of gait pattern according to the injury aspect of the neural track in a stroke patient. Methods: One patient and six control subjects of similar age participated. A 19-year-old male patient with spontaneous intracerebral hemorrhage on right basal ganglia, thalamus, corona radiata and cerebral cortex due to arteriovenous malformation rupture. Diffusion tensor imaging (DTI) data was acquired 21 months after the stroke. Kinematic and spatio-temporal parameters of gait were collected using a three-dimensional gait analysis system. Results: On 21 months DTI, the CST and CRP in affected hemisphere showed severe injury, in contrast, the VST in affected hemisphere showed intact integrity. Result of gait analysis, walking distance and speed were significantly decreased in a patient. The stance rate of unaffected lower limb, the swing rate of affected lower limb and the duration of double stance significantly increased compared with normal control. The knee and hip joint angle were significantly decreased in a patient. Conclusion: We found recovered independent gait ability may be associated with unimpaired VST in a patient with severe injury in CST and CRP.

Characteristics of the Compensation for Gait of the Induced Knee Stiffness in Normal Subjects (정상인 보행에서 무릎관절의 유도된 강직에 따른 신체 보상 특성)

  • Woo, Byung-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.357-367
    • /
    • 2013
  • The purposes of this study were investigated physical compensation for gait on induced knee stiffness in normal subjects. Ten subjects were participated in the experiment(age: $26.0{\pm}6.3$ yrs, height: $175.5{\pm}5.3$ cm, weight: $69.1{\pm}6.1$ kg). The study method adopted 3D analysis with five cameras and ground reaction force with two force-plate. Induced knee stiffness level were classified as gait pattern on ROM of knee(free level, $30^{\circ}$ restriction level, fix level). The results were as follows; In angular displacement of hip joint, left hip joint was the more extended in mid-stance on induced right knee stiffness. In angular displacement of knee joint, there was no physical compensation on induced right knee stiffness, but free knee level gait was more flexed in swing phase of right knee joint. In angular displacement of ankle joint, right ankle joint was the more dorsiflexed on induced right knee stiffness, and $30^{\circ}$ restriction level and fix level gait were less plantarflexed in TO2. In trunk tilt, free and $30^{\circ}$ restriction level gait was more backward tilt on induced right knee stiffness. In ROM of each joint, right knee joint was more larger and trunk tilt was more lower on induced right knee stiffness. In GRF, Fx was more bigger lateral force in free and $30^{\circ}$ restriction level gait, and was more bigger medial force in fix level gait. Fy was more bigger propulsion force in free level gait, and was was more bigger braking force in $30^{\circ}$ restriction level gait. Left braking force in $30^{\circ}$ restriction level gait was more bigger. Fz was no significant.

Comparison of Motion Sensor Systems for Gait Phase Detection (보행주기 검출용 모션 센서 시스템의 비교)

  • Park, Sun-Woo;Sohn, Ryang-Hee;Ryu, Ki-Hong;Kim, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

Gait Characteristic in a Stroke Patient with an Intact Corticospinal Tract and Corticoreticular Pathway: A Case Study

  • Yeo, Sang Seok;Cho, In Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.2
    • /
    • pp.73-77
    • /
    • 2018
  • Purpose: The prefrontal lobe, supplementary motor area, cerebellum, and basal ganglia are activated during gait. In addition, gait is controlled by nerves, such as the corticospinal tract (CST) and corticoreticular pathway (CRP). In this study, the presence of an injury to the CST and CRP was identified by diffusion tensor imaging and the characteristics of the gait pattern were investigated according to inferior cerebral artery infarction. Methods: One patient and six control subjects of a similar age participated. A 69-year-old female patient had an injury to the left basal ganglia, insular gyrus, corona radiata, dorsolateral prefrontal cortex, and postcentral gyrus due to an inferior cerebral artery infarction. Diffusion tensor imaging (DTI) data was acquired 4 weeks after the stroke. The kinematic and spatio-temporal parameters of gait were collected using a three-dimensional gait analysis system. Results: On 4 weeks DTI, the CST and CRP in the affected hemisphere did not show injury to the affected and unaffected hemisphere. Gait analysis showed that the cadence of spatio-temporal parameter was decreased significantly in the patient. The angle of the knee joint was decreased significantly in the affected and unaffected sides compared to the control group. Conclusion: The results of diffusion tensor imaging showed that although the patient was evaluated to be capable of an independent gait, the quality and quantity of gait might be reduced. This study could help better understand the gait ability analysis of stroke patients and the abnormal gait pattern of patients with a brain injury.

Gait Recognition Using Shape Sequence Descriptor (Shape Sequence 기술자를 이용한 게이트 인식)

  • Jeong, Seung-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2339-2345
    • /
    • 2011
  • Gait recognition is the method to identify the person who walks in front of camera using characteristics of individuals by a sequence of images of walking people. The accuracy of biometric such as fingerprint or iris is very high; however, to provide information needs downsides which allow users to direct contact or close-up, etc. There have been many studies in gait recognition because it could capture images and analysis characteristics far from a person. In order to recognize the gait of person needs a continuous sequence of walking which can be distinguished from the individuals should be extracted features rather than an single image. Therefore, this paper proposes a method of gait recognition that the motion of objects in sequence is described the characteristics of a shape sequence descriptor, and through a variety of experiments can show possibility as a recognition technique.

Gait Analysis on the Elderly Women with Foot Scan (Foot Scan 측정을 통한 노년 여성의 보행 분석)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.613-619
    • /
    • 2013
  • This study compares the gait characteristics of elderly women during barefoot walking and walking with sneakers. We measured foot angles, max foot pressure, peak plantar pressure of each plantar region, velocity of Center of Pressure(COP), and axis shifting of COP with an RS-scan system. Elderly women's foot angles were narrower when walking with sneakers than when barefoot walking. We found that the subtalar joint angle (representing ankle joint flexibility) affected walking stability. Regarding the peak plantar pressure of each foot region, pressures were high in the medial regions and the pressures greatly varied depending on the region measured during barefoot walking. The COP moved significantly faster when walking with sneakers than barefoot walking and suggests that elderly women walked faster in sneakers. Axis shifting of the COP decreased during walking with sneakers and indicated that gait balance improved when walking with sneakers. The findings of the present study can be utilized as foundational data for elderly women's gait characteristics as well as data for the production of functional footwear. Future research that focuses on various types of shoes, age groups, and gender are recommended for the development of more functional footwear for stable gaits.

A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain (만성요통환자의 보행특성에 관한 연구)

  • Kim, Kyoung;Ko, Joo-Yeon;Lee, Sung-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

Single Gyroscope Sensor Module System for Gait Event Detection (보행시점 검출을 위한 단일 각속도 센서모듈 시스템)

  • Kang, Dong-Won;Choi, Jin-Seung;Kim, Han-Su;Oh, Ho-Sang;Seo, Jeong-Woo;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.495-501
    • /
    • 2011
  • The purpose of this study was to develop the inertial sensor module system to detect gait event using single angular rate sensor(gyroscope), and evaluate the accuracy of this system. This sensor module is attached at the heel and gait events such as heel strike, foot flat, heel off, toe off are detected by using proposed automatic event detection algorithm. The developed algorithm detect characteristics of pitch data of the gyroscope to find gait event. To evaluate the accuracy of system, 3D motion capture system was used and synchronized with sensor module system for comparison of gait event timings. In experiment, 6 subjects performed 5 trials level walking with 3 different conditions such as slow, preferred and fast. Results showed that gait event timings by sensor module system are similar to that by kinematic data, because maximum absolute errors were under 37.4msec regardless of gait velocity. Therefore, this system can be used to detect gait events. Although this system has advantages of small, light weight, long-term monitoring and high accuracy, it is necessary to improve the system to get other gait information such as gait velocity, stride length, step width and joint angles.

Change of gait pattern of a patient with ataxic gait by cerebellar infarction (소뇌 경색 환자의 임상양상에 따른 보행의 변화)

  • Hong, Haejin;Choi, Sanho;Lee, Ilsuk;Oh, Jaegun;Sung, Kang-keyng;Lee, Sangkwan
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • ■ Objectives The goal of this pilot study is to observe the change of gait pattern according to the clinical status in a patient with ataxic gait by cerebellar infarction. ■ Methods We measured the spatiotemporal gait parameters of a patient with ataxic gait four times, in which, first, the patient was not able to walk independently, second, able to walk independently, third, unable to walk independently by general tremor, and, last, able to walk independently after disappearing of general tremor. ■ Results When a patient with cerebellar ataxic gait was able to walk independently and the cerebellar tremor was disappeared, the change of gait pattern was that step and stride length decreased and total double support and stance phase increased. ■ Conclusion When different clinical characteristics were improved, the change of gait showed same pattern.

  • PDF