• 제목/요약/키워드: Gait

검색결과 2,439건 처리시간 0.043초

하지 진단 및 재활을 위한 각속도계 기반 측정시스템 (Gait Estimation System for Leg Diagnosis and Rehabilitation using Gyroscopes)

  • 이민영;이수용
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.866-871
    • /
    • 2010
  • Gait analysis is essential for leg diagnosis and rehabilitation for the patients, the handicapped and the elderly. The use of 3D motion capture device for gait analysis is very common for gait analysis. However, this device has several shortcomings including limited workspace, visibility and high price. Instead, we developed gait estimation system using gyroscopes. This system provides gait information including the number of gaits, stride and walking distance. With four gyroscope (one for each leg's thigh and calf) outputs, the proposed gait modeling estimates the movements of the hip, the knees and the feet. Complete pedestrian localization is implemented with gait information and the heading angle estimated from the rate gyro and the magnetic compass measurements. The developed system is very useful for diagnosis and the rehabilitation of the pedestrian at the hospital. It is also useful for indoor localization of the pedestrians.

여성 노인의 장애물과 이중 과제 보행 시 속도 및 하지근육 활성도 변화 (Analysis of Gait Velocity, Lower Muscles Activity on Obstacle and Dual Task Gait in Elderly Women)

  • 조용호
    • 대한물리의학회지
    • /
    • 제6권4호
    • /
    • pp.465-473
    • /
    • 2011
  • Purpose : This study was to evaluate gait velocity and muscle activity on 3 different gait conditions in elderly women. Methods : There were one group was 20's generation(n=12), and the other group was over 60's generation (n=12). The velocity of gait was analysed for using the Footscan system, EMG(MP150) for muscle activity. Subjects were measured 3 gait condition(normal, obstacle-10cm, dual obstacle-10cm. Measured values were used by the independent t-test for analysing between groups, and repeated measurement of ANOVA for analysing within group. Results : The results were as follow: velocity and acticities of lower 4 muscles were significantly differences in experimental group. In control group, there were not significantly differences. Contrast-groups were significantly differences of velocity(obstacle, dual obstacle), muscle activities(soleus-dual obstacle, hamstring-all). Conclusion : These results indicate that elderly people are reduced gait ability in dual task, and obstacle gait. So Elderly women need to training obstacle/dual gait for preventing falling.

키높이 깔창이 성인남성의 보행 및 발의 압력분포에 미치는 영향 (The Effect of Height Increase Elevator Shoes Insole on Gait and Foot Pressure)

  • 구봉오
    • 대한물리의학회지
    • /
    • 제6권2호
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of 0cm, 2.5cm, 5cm height increase elevator shoes insole on gait and foot pressure Methods: Fifteen young adult were recruited this study. Gait and foot was measured by Gait AnalyzerTM(Tech Storm Inc. korea). Statistical analysis was used one-way ANOVA to know difference between 0cm, 2.5cm insole and 5cm insole Results: There was no significantly difference on foot length, foot width, foot angle, step time during gait. But step length and step width was significantly difference during gait. There was no significantly difference on gait ratio during stance phase. There was significantly difference on forefoot pressure and rearfoot pressure ratio. Conclusion: These results indicate that height increase elevator shoes insole may be caused step length, step width decreaseed during gait. It caused forefoot pressure increased and rearfoot pressure decreased on foot.

가속도센서를 이용한 편마비성보행 평가 (Evaluation of Hemiplegic Gait Using Accelerometer)

  • 이준석;박수지;신항식
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1634-1640
    • /
    • 2017
  • The study aims to distinguish hemiplegic gait and normal gait using simple wearable device and classification algorithm. Thus, we developed a wearable system equipped three axis accelerometer and three axis gyroscope. The developed wearable system was verified by clinical experiment. In experiment, twenty one normal subjects and twenty one patients undergoing stroke treatment were participated. Based on the measured inertial signal, a random forest algorithm was used to classify hemiplegic gait. Four-fold cross validation was applied to ensure the reliability of the results. To select optimal attributes, we applied the forward search algorithm with 10 times of repetition, then selected five most frequently attributes were chosen as a final attribute. The results of this study showed that 95.2% of accuracy in hemiplegic gait and normal gait classification and 77.4% of accuracy in hemiplegic-side and normal gait classification.

Gait Motion Capture 및 족압 측정을 이용한 보행특성시험 및 동력학적 인체 시뮬레이션 연구 : 한국인 성인 남자의 군장착용 보행 특성 해석 (A Study on the Gait Test Human Dynamic Simulation Using Gait Motion Capture and Foot Pressure Measurement : Analysis of Gait Pattern with Wearing Military Equipment of Korean Male Adult)

  • 이세훈;이영신;최영진;이장원;채제욱;최의중;김인우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.877-880
    • /
    • 2005
  • This paper suggests gait analysis and gait simulation method using Gait Motion Capture equipment and plantar pressure measurement system. The gait of normal person and how it will be effected by added weight with wearing military equipments are studied by suggested method. It is measured that a change of gait pattern when wears military equipments with Korean male adult(height 180 cm, weight 70 kg) and simulated its results.

  • PDF

FES 보행을 위한 보행 이벤트 검출 (Gait-Event Detection for FES Locomotion)

  • 허지운;김철승;엄광문
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.170-178
    • /
    • 2005
  • The purpose of this study is to develop a gait-event detection system, which is necessary for the cycle-to-cycle FES control of locomotion. Proposed gait event detection system consists of a signal measurement part and gait event detection part. The signal measurement was composed of the sensors and the LabVIEW program for the data acquisition and synchronization of the sensor signals. We also used a video camera and a motion capture system to get the reference gait events. Machine learning technique with ANN (artificial neural network) was adopted for automatic detection of gait events. 2 cycles of reference gait events were used as the teacher signals for ANN training and the remnants ($2\sim5$ cycles) were used fur the evaluation of the performance in gait-event detection. 14 combinations of sensor signals were used in the training and evaluation of ANN to examine the relationship between the number of sensors and the gait-event detection performance. The best combinations with minimum errors of event-detection time were 1) goniometer, foot-switch and 2) goniometer, foot-switch, accelerometer x(anterior-posterior) component. It is expected that the result of this study will be useful in the design of cycle-to-cycle FES controller.

임상 물리치료사의 경험에 따른 시각적 보행 분석의 신뢰도 연구 (Reliability of Visual Gait Analysis according to Clinical Experience Level of Physical Therapists)

  • 이인희
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.174-179
    • /
    • 2013
  • Purpose: Visual gait analysis plays a pivotal role in determining the important gait problem of patients. A few studies have been published and have received little attention regarding visual gait analysis on patients with orthopedic problems. The purposes of this study were to investigate the difference of reliability levels according to experience of clinical physical therapists. Methods: Thirty-five clinical physical therapists, 5 high experienced, 15 experienced, and 15 inexperienced, were recruited and individually evaluated these videotaped gait patterns of the participants, and filled up the structured gait analysis form. The gait of nine participants was videotaped. Reliability levels were calculated by the Intraclass Correlation Coefficients (ICC). Results: The inter-rater reliability of high experienced group (ICC=0.56; 95% CI: 0.50-0.62) was comparable to that of the experienced raters (ICC=0.48; 95% CI: 0.43-0.53) and inexperienced group (ICC=0.42; 95% CI: 0.38-0.46). High experienced group reached a higher inter-rater reliability level. The average intra-rater reliability of the high experienced group was 0.70 (ICCs ranging from 0.54 to 0.82). The experienced group reached an average intra-rater reliability of 0.61 (ICCs ranging from 0.47 to 0.81). The inexperienced group attained average ICC values of 0.53 (ICCs ranging from 0.30 to 0.74). Conclusion: Use of a structured gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis.

Clinical Criteria to Perform the Step through Step Gait with a Cane in Chronic Stroke Patients

  • Kim, Won-Bok;Lee, Jung-Ho
    • 대한물리의학회지
    • /
    • 제9권3호
    • /
    • pp.285-291
    • /
    • 2014
  • PURPOSE: The purpose of this study was to propose clinical criteria to differentiate patients who are able to perform the step-through-step gait pattern in chronic stroke patients. METHODS: Sixty patients with chronic stroke patients participated this study. To differentiate patients who could perform the step-through-step gait pattern, age, gender, and causes of stroke were noted, a Chedoke-McMaster (CM) damage list, Fugl-Meyer (FM) assessment scales and the Berg Balance Scale (BBS) were determined. A 10 meter gait test and Timed Up and Go (TUG) test were conducted to determine the differences in gait speed and dynamic balance between patients walking with or without canes in the step-through-step gait pattern group. RESULTS: There was no significant statistical difference in age, gender, and stroke type between all subjects. There were significant differences in the CM scale for postural and lower extremities, and FM scale for lower extremities and BBS. The dynamic balance ability and gait speed showed significant differences between the subjects in the step-through-step gait pattern with or without a cane during gait. CONCLUSION: CM and FM scales for the lower extremities and postural control, as well as BBS scales, can be used as criteria to differentiate patients who are able to perform the step-through-step gait pattern. These results can also be used to provide beneficial information to patients that are walking with canes.

정상 성인의 운동역학적 보행분석 (A Study on Kinetic Gait Analysis of the Normal Adult)

  • 김건;윤나미
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.87-95
    • /
    • 2009
  • Purpose: This study reports the basic reference data of the specific gait parameters for Korean normal adults. Methods: The basic gait parameters were extracted from 73 Adults (35 men and 38 women), 18 to 33 years of age, using a Vicon MX motion analysis system. The segment kinetics, such as joint moment and power, was analyzed at the hip, knee and ankle. Results: The motion patterns are typically associated with a specific phase of the gait cycle. The temporal-spatial gait parameters of Korean normal adults, such as cadence, walking speed, stride length, single support and double support, were similar to the other western reference data. The kinetic parameters of Korean normal adults, such as joint moments of force, joint mechanical power generation or absorption and ground reaction forces, were also similar to other western reference datasets. Conclusion: This study demonstrates that objective gait analysis can be used to document the gait patterns of normal healthy adults. The techniques of 3-dimensional temporal-spatial gait parameters and kinematic parameters analysis can provide a detailed biomechanical description of a normal and pathological gait.

  • PDF

뇌졸중 환자에서 Dynamic Gait Index와 Berg Balance Scale 및 Timed Up & Go 검사간의 상관관계 (The Correlations among the Dynamic Gait Index the Berg Balance Scale and Timed Up & Go Test in people with stroke)

  • 이상호;황병용
    • 대한물리치료과학회지
    • /
    • 제15권3호
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this study was to compare the relationship among the Dynamic Gait Index(DGI), Berg Balance Scale(BBS) scores, Timed Up & Go Test(TUG), and subject characteristics. The subjects were fifteen stroke with hemiplegia were chosen in the Konyang University Hospital. Dynamic balance was measured Dynamic Gait Index(DGI), and balance was measured using Berg Balance Scale(BBS). Timed Up & Go Test(TUG) was used to evaluate functional mobility. Data were analyzed using Spearman correlation. There was significant correlated among Dynamic Gait Index(DGI), Berg Balance Scale(BBS) and Timed Up & Go Test(TUG)(p<.01). The correlation among subject characteristics and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG) score was significant result in r = -.527 from Dynamic Gait Index(DGI) and pathogenesis(p<.05). There were no significant statistical differences among the types of spasticity and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG). The comparison among the sex, type of hemiplegia, pain, pathogenesis and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG) score was significant result in pathogenesis(p<.05). The results of this study showed that there was high correlations among the Dynamic Gait Index(DGI) and balance test of people with stroke.

  • PDF